Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands

被引:13
|
作者
Kassa, Adane [2 ]
Amare, Meareg [1 ]
机构
[1] Bahir Dar Univ, Bahir Dar, Ethiopia
[2] Debremarkos Univ, Debremarkos, Ethiopia
关键词
Amoxicillin; Antibiotics; β -Lactam; Electropolymerization; Spike recovery; Standard addition;
D O I
10.1186/s13065-021-00739-0
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background Amoxicillin (AMX), which is one of the beta-lactam antibiotics used in the treatment of bacterial infections, is known to have a serious mechanism of resistance necessitating continuous monitoring of its level in pharmaceutical and serum samples. Results In this study, we presented selective, accurate, and precise square wave voltammetric method based on poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode (poly(AHNSA/GCE)) for determination of amoxicillin in four selected tablet brands. Appearance of a peak in the oxidative scan direction without a peak in the reductive direction of cyclic voltammograms of both bare GCE and poly(AHNSA/GCE) with four folds current and much reduced potential on the modified electrode showed catalytic property of the modifier towards oxidation of AMX. While cyclic voltammetric studies of effect of scan rate showed predominantly diffusion controlled oxidation of AMX with one electron participation, effect of pH revealed participation of protons and electrons in a 1:1 ratio. The square wave voltammetric peak current response of the modified electrode for AMX showed linear dependence on the concentration of the spiked standard AMX in the range 10-150 mu mol L-1 with 9.9 nmol L-1 LOD. The AMX content of the studied tablet brands were found in the range 97.84-100.78% of the labeled value. Spike recovery results of 99.6-100.5%, and interference recovery results of 95.4-100.8% AMX in the presence of 50-200% of ampicillin and cloxicillin validated the applicability of the method for determination of amoxicillin in tablet formulation. Conclusion In contrast to the previously reported works on determination of amoxicillin, the present method showed an excellent performance making it a potential method for determination of amoxicillin in real samples including serum samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Electrocatalytic oxidation of hydrazine on poly(4-aminobenzene sulfonic acid)-modified glassy carbon electrode
    M. Sadikoglu
    S. Yilmaz
    I. Kurt
    B. Selvi
    H. Sari
    N. Erduran
    E. Usta
    G. Saglikoglu
    Russian Journal of Electrochemistry, 2016, 52 : 539 - 545
  • [42] Electrocatalytic oxidation of hydrazine on poly(4-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Sadikoglu, M.
    Yilmaz, S.
    Kurt, I.
    Selvi, B.
    Sari, H.
    Erduran, N.
    Usta, E.
    Saglikoglu, G.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2016, 52 (06) : 539 - 545
  • [43] Voltammetric determination of a benzimidazole anthelmintic mixture at a poly(3-methylthiophene)-modified glassy carbon electrode
    Msagati, TAM
    Ngila, JC
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2003, 56 : 5 - 9
  • [44] Removal of Cr(VI) from aqueous solution using electrosynthesized 4-amino-3-hydroxynaphthalene-1-sulfonic acid doped polypyrrole as adsorbent
    Mohamed Lamine Sall
    Abdou Karim Diagne Diaw
    Diariatou Gningue-Sall
    Alexandre Chevillot-Biraud
    Nihal Oturan
    Mehmet Ali Oturan
    Jean-Jacques Aaron
    Environmental Science and Pollution Research, 2017, 24 : 21111 - 21127
  • [45] Application of Glassy Carbon Electrode Modified with Co3O4 Nanoparticles for Voltammetric Determination of Folic Acid
    Kondori, Tahere
    Akbarzadeh-Torbati, Niloufar
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (09): : 1211 - 1221
  • [46] Removal of Cr(VI) from aqueous solution using electrosynthesized 4-amino-3-hydroxynaphthalene-1-sulfonic acid doped polypyrrole as adsorbent
    Sall, Mohamed Lamine
    Diaw, Abdou Karim Diagne
    Gningue-Sall, Diariatou
    Chevillot-Biraud, Alexandre
    Oturan, Nihal
    Oturan, Mehmet Ali
    Aaron, Jean-Jacques
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (26) : 21111 - 21127
  • [47] Sensitive voltammetric determination of paracetamol by poly (4-vinylpyridine)/multiwalled carbon nanotubes modified glassy carbon electrode
    Ghadimi, Hanieh
    Tehrani, Ramin M. A.
    Ali, Abdussalam Salhin Mohamed
    Mohamed, Norita
    Ab Ghani, Sulaiman
    ANALYTICA CHIMICA ACTA, 2013, 765 : 70 - 76
  • [48] A glassy carbon electrode modified with antimony and poly(p-aminobenzene sulfonic acid) for sensing lead(II) by square wave anodic stripping voltammetry
    Yi, Wen Jiao
    Li, Yang
    Ran, Gu
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2012, 179 (1-2) : 171 - 177
  • [49] A glassy carbon electrode modified with antimony and poly(p-aminobenzene sulfonic acid) for sensing lead(II) by square wave anodic stripping voltammetry
    Wen Jiao Yi
    Yang Li
    Gu Ran
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2012, 179 : 171 - 177
  • [50] Erratum to: “Electrocatalytic oxidation of hydrazine on poly(4-aminobenzene sulfonic acid)-modified glassy carbon electrode”
    M. Sadikoglu
    S. Yilmaz
    I. Kurt
    B. Selvi
    H. Sari
    N. Erduran
    E. Usta
    G. Saglikoglu
    Russian Journal of Electrochemistry, 2016, 52 : 1202 - 1202