Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands

被引:13
|
作者
Kassa, Adane [2 ]
Amare, Meareg [1 ]
机构
[1] Bahir Dar Univ, Bahir Dar, Ethiopia
[2] Debremarkos Univ, Debremarkos, Ethiopia
关键词
Amoxicillin; Antibiotics; β -Lactam; Electropolymerization; Spike recovery; Standard addition;
D O I
10.1186/s13065-021-00739-0
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background Amoxicillin (AMX), which is one of the beta-lactam antibiotics used in the treatment of bacterial infections, is known to have a serious mechanism of resistance necessitating continuous monitoring of its level in pharmaceutical and serum samples. Results In this study, we presented selective, accurate, and precise square wave voltammetric method based on poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode (poly(AHNSA/GCE)) for determination of amoxicillin in four selected tablet brands. Appearance of a peak in the oxidative scan direction without a peak in the reductive direction of cyclic voltammograms of both bare GCE and poly(AHNSA/GCE) with four folds current and much reduced potential on the modified electrode showed catalytic property of the modifier towards oxidation of AMX. While cyclic voltammetric studies of effect of scan rate showed predominantly diffusion controlled oxidation of AMX with one electron participation, effect of pH revealed participation of protons and electrons in a 1:1 ratio. The square wave voltammetric peak current response of the modified electrode for AMX showed linear dependence on the concentration of the spiked standard AMX in the range 10-150 mu mol L-1 with 9.9 nmol L-1 LOD. The AMX content of the studied tablet brands were found in the range 97.84-100.78% of the labeled value. Spike recovery results of 99.6-100.5%, and interference recovery results of 95.4-100.8% AMX in the presence of 50-200% of ampicillin and cloxicillin validated the applicability of the method for determination of amoxicillin in tablet formulation. Conclusion In contrast to the previously reported works on determination of amoxicillin, the present method showed an excellent performance making it a potential method for determination of amoxicillin in real samples including serum samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Spectroscopic, Computational, Molecular Docking and Dynamics Simulations Studies of 4-Amino-3-hydroxyNaphthalene-1-Sulfonic Acid (ANSA)
    Pathan, Hero Khan
    Fatima, Aysha
    Garg, Pankaj
    Muthu, S.
    Yadav, Anjali
    Siddiqui, Nazia
    Ali, Mariyam
    Javed, Saleem
    POLYCYCLIC AROMATIC COMPOUNDS, 2024, 44 (06) : 3787 - 3806
  • [22] Sensitive determination of phenylephrine and chlorprothixene at poly(4-aminobenzene sulfonic acid) modified glassy carbon electrode
    Huang, Fei
    Jin, Guiying
    Liu, Yang
    Kong, Jilie
    TALANTA, 2008, 74 (05) : 1435 - 1441
  • [23] Square wave voltammetric determination of quercetin in wine and fruit juice samples at poly (safranine O) modified glassy carbon electrode
    Tesfaye, Gizaw
    Hailu, Tesfu
    Ele, Estifanos
    Negash, Negussie
    Tessema, Merid
    SENSING AND BIO-SENSING RESEARCH, 2021, 34
  • [24] Determination of gentamicin by using square wave anodic stripping voltammetry with poly (β-cyclodextrin-p-toluene sulfonic acid) modified glassy carbon electrode
    Burc, Muammer
    Titretir Duran, Serap
    Gungor, Oznur
    Karagozler, Ali Ersin
    POLYMER BULLETIN, 2024, 81 (07) : 6381 - 6403
  • [25] Determination of gentamicin by using square wave anodic stripping voltammetry with poly (β-cyclodextrin-p-toluene sulfonic acid) modified glassy carbon electrode
    Muammer Burç
    Serap Titretir Duran
    Öznur Güngör
    Ali Ersin Karagözler
    Polymer Bulletin, 2024, 81 : 6381 - 6403
  • [26] Electrochemical Sensor for Square Wave Voltammetric Determination of Clozapine by Glassy Carbon Electrode Modified by WO3 Nanoparticles
    Fat'hi, Mohammad Reza
    Almasifar, Dariush
    IEEE SENSORS JOURNAL, 2017, 17 (18) : 6069 - 6076
  • [27] Determination of Rutin on the Poly(p-aminobenzene sulfonic acid) Modified Glassy Carbon Electrode
    Chen, Xiaoyin
    Wang, Zonghua
    Zhang, Feifei
    Zhu, Lingyan
    Li, Yanhui
    Xia, Yanzhi
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (04) : 475 - 478
  • [28] EDTA salt modified carbon paste electrode for square wave voltammetric determination of theophylline in pharmaceutical tablet formulation
    Moges, Amsalu
    Dawit, Mulugeta
    Turbale, Mahilet
    Amare, Meareg
    PLOS ONE, 2022, 17 (06):
  • [29] Voltammetric determination of florfenicol by using poly(3-methylthiophene) modified glassy carbon electrode
    Taskin, Imren
    Gungor, Oznur
    Titretir Duran, Serap
    POLYMER BULLETIN, 2021, 78 (08) : 4721 - 4741
  • [30] Voltammetric determination of florfenicol by using poly(3-methylthiophene) modified glassy carbon electrode
    İmren Taşkın
    Öznur Güngör
    Serap Titretir Duran
    Polymer Bulletin, 2021, 78 : 4721 - 4741