Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands

被引:13
|
作者
Kassa, Adane [2 ]
Amare, Meareg [1 ]
机构
[1] Bahir Dar Univ, Bahir Dar, Ethiopia
[2] Debremarkos Univ, Debremarkos, Ethiopia
关键词
Amoxicillin; Antibiotics; β -Lactam; Electropolymerization; Spike recovery; Standard addition;
D O I
10.1186/s13065-021-00739-0
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background Amoxicillin (AMX), which is one of the beta-lactam antibiotics used in the treatment of bacterial infections, is known to have a serious mechanism of resistance necessitating continuous monitoring of its level in pharmaceutical and serum samples. Results In this study, we presented selective, accurate, and precise square wave voltammetric method based on poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode (poly(AHNSA/GCE)) for determination of amoxicillin in four selected tablet brands. Appearance of a peak in the oxidative scan direction without a peak in the reductive direction of cyclic voltammograms of both bare GCE and poly(AHNSA/GCE) with four folds current and much reduced potential on the modified electrode showed catalytic property of the modifier towards oxidation of AMX. While cyclic voltammetric studies of effect of scan rate showed predominantly diffusion controlled oxidation of AMX with one electron participation, effect of pH revealed participation of protons and electrons in a 1:1 ratio. The square wave voltammetric peak current response of the modified electrode for AMX showed linear dependence on the concentration of the spiked standard AMX in the range 10-150 mu mol L-1 with 9.9 nmol L-1 LOD. The AMX content of the studied tablet brands were found in the range 97.84-100.78% of the labeled value. Spike recovery results of 99.6-100.5%, and interference recovery results of 95.4-100.8% AMX in the presence of 50-200% of ampicillin and cloxicillin validated the applicability of the method for determination of amoxicillin in tablet formulation. Conclusion In contrast to the previously reported works on determination of amoxicillin, the present method showed an excellent performance making it a potential method for determination of amoxicillin in real samples including serum samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands
    Adane Kassa
    Meareg Amare
    BMC Chemistry, 15
  • [2] Voltammetric Determination of Nicotine at Poly(4-Amino-3-Hydroxynaphthalene Sulfonic Acid)-Modified Glassy Carbon Electrode
    Geto, Alemnew
    Amare, Maereg
    Tessema, Merid
    Admassie, Shimelis
    ELECTROANALYSIS, 2012, 24 (03) : 659 - 665
  • [3] DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF THEOPHYLLINE AT POLY(4-AMINO-3-HYDROXYNAPHTHALENE SULFONIC ACID) MODIFIED GLASSY CARBON ELECTRODE
    Amare, Meareg
    Admassie, Shimelis
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2012, 26 (01) : 73 - 84
  • [4] Simultaneous determination of caffeine and paracetamol by square wave voltammetry at poly(4-amino-3-hydroxynaphthalene sulfonic acid)-modified glassy carbon electrode
    Tefera, Molla
    Geto, Alemnew
    Tessema, Merid
    Admassie, Shimelis
    FOOD CHEMISTRY, 2016, 210 : 156 - 162
  • [5] Potentiodynamic fabrication and characterization of poly(4-amino-3-hydroxynaphthalene sulfonic acid) modified glassy carbon electrode
    Amare, Meareg
    Admassie, Shimelis
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2020, 9 (05): : 11484 - 11496
  • [6] Poly (4-Amino-3-Hydroxynaphthalene Sulfonic Acid)-Modified Glassy Carbon Electrode for Electrochemical Detection of Ephedrine in Human Urine
    Amare, Meareg
    Lakew, Worku
    Admassie, Shimelis
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2011, 3 (04): : 365 - 378
  • [7] Sensitive Voltammetric Determination of Paracetamol on Poly(4-Aminobenzene Sulfonic Acid) Modified Glassy Carbon Electrode
    Yilmaz, Selehattin
    Bas, Zeynep
    Sadikoglu, Murat
    Yagmur, Sultan
    Saglikoglu, Gulsen
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (07): : 6244 - 6255
  • [8] Square Wave Voltammetric Determination of Ibuprofen at Poly(L-Aspartic Acid) Modified Glassy Carbon Electrode
    Mekassa, Birhanu
    Tessema, Merid
    Chandravanshi, Bhagwan Singh
    Tefera, Molla
    IEEE SENSORS JOURNAL, 2018, 18 (01) : 37 - 44
  • [9] Voltammetric Determination of UricAcid on Poly(p-Aminobenzene Sulfonic Acid)-Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Taskin, Gamze
    Demirtas, Fatma Gul
    Selvi, Bedrettin
    Barut, Mustafa
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 11550 - 11557
  • [10] Poly(alizarin red S) modified glassy carbon electrode for square wave adsorptive stripping voltammetric determination of metronidazole in tablet formulation
    Dawit, Mulugeta
    Turbale, Mahilet
    Moges, Amsalu
    Amare, Meareg
    PLOS ONE, 2020, 15 (12):