Precise Frequency Comparison System Using Bidirectional Optical Amplifiers

被引:44
作者
Amemiya, Masaki [1 ]
Imae, Michito [1 ]
Fujii, Yasuhisa [1 ]
Suzuyama, Tomonari [1 ]
Hong, Feng-Lei [1 ]
Takamoto, Masao [2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058563, Japan
[2] Univ Tokyo, Dept Appl Phys, Grad Sch Engn, Tokyo 1138656, Japan
关键词
Bidirectional optical amplifier; frequency comparison; frequency stability; frequency standard; optical fiber; wavelength division multiplexing (WDM); FIBER; TRANSMISSION; STANDARDS;
D O I
10.1109/TIM.2009.2025073
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Precise frequency comparisons are becoming more urgent given the recent rapid progress in next-generation frequency standards. This paper describes a new type of bidirectional optical amplifier that overcomes the fiber loss limits that have prevented accurate frequency comparisons between widely separated places; such comparison is realized by bidirectionally transmitting wavelength-division-multiplexed (WDM) signals along a single fiber. The proposed optical amplifier has an optical isolator in each two-way channel divided by wavelength filters to suppress the optical reflection that causes amplification instability. The additional insertion optical loss due to this method is about 1.5 dB. The optical gain greater than 30 dB is obtained for both signals with good optical isolation of 65 dB. A radio-frequency reference signal can directly be sent by simple intensity modulation and direct detection (IM-DD) devices in the 1550-nm region widely used in telecommunication networks. Phase comparisons of the received signals and the frequency standards at each terminal are used for frequency comparisons. The amplifier is tested in the field using two hydrogen masers. A 120-km fiber with loss of 52.5 dB is used to connect the National Metrology Institute of Japan (NMIJ) to the University of Tokyo. Because of this loss, an amplifier is needed to realize sufficient receiving power. The frequency stability of the system with a 10-MHz direct transmission is evaluated by returning the optical signal from a halfway point [55 km from the NMIJ] where the amplifier is installed. The result is 2.6 x 10(-16) (Allan deviation) with the averaging time of 7 x 10(4) s. The laboratory result is 8.7 x 10(-17) (tau = 4 x 10(4) s). The amplifier's long-term stability is promising for stable frequency dissemination in addition to precise frequency comparisons.
引用
收藏
页码:631 / 640
页数:10
相关论文
共 28 条
[1]  
AMEMIYA M, 2006, IEEJ T FUNDAM MAT, V126, P458
[2]   Simple time and frequency dissemination method using optical fiber network [J].
Amemiya, Masaki ;
Imae, Michito ;
Fujii, Yasuhisa ;
Suzuyama, Tomonari ;
Ohshima, Shin-ichi .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (05) :878-883
[3]   CHARACTERIZATION OF FREQUENCY STABILITY [J].
BARNES, JA ;
CHI, AR ;
CUTLER, LS ;
HEALEY, DJ ;
LEESON, DB ;
MCGUNIGAL, TE ;
MULLEN, JA ;
SMITH, WL ;
SYDNOR, RL ;
VESSOT, RFC ;
WINKLER, GMR .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1971, IM20 (02) :105-+
[4]   Comparison between frequency standards in Europe and the USA at the 10-15 uncertainty level [J].
Bauch, A ;
Achkar, J ;
Bize, S ;
Calonico, D ;
Dach, R ;
Hlavac, R ;
Lorini, L ;
Parker, T ;
Petit, G ;
Piester, D ;
Szymaniec, K ;
Uhrich, P .
METROLOGIA, 2006, 43 (01) :109-120
[5]   Long-distance frequency dissemination with a resolution of 10-17 -: art. no. 203904 [J].
Daussy, C ;
Lopez, O ;
Amy-Klein, A ;
Goncharov, A ;
Guinet, M ;
Chardonnet, C ;
Narbonneau, F ;
Lours, M ;
Chambon, D ;
Bize, S ;
Clairon, A ;
Santarelli, G ;
Tobar, ME ;
Luiten, AN .
PHYSICAL REVIEW LETTERS, 2005, 94 (20)
[6]   Coherent optical phase transfer over a 32-km fiber with 1 s instability at 10-17 [J].
Foreman, Seth M. ;
Ludlow, Andrew D. ;
de Miranda, Marcio H. G. ;
Stalnaker, Jason E. ;
Diddams, Scott A. ;
Ye, Jun .
PHYSICAL REVIEW LETTERS, 2007, 99 (15)
[7]   Ultra-stable frequency dissemination via optical fiber at NICT [J].
Fujieda, M. ;
Kumagai, M. ;
Gotoh, T. ;
Hosokawa, M. .
2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, :320-321
[8]  
FUJII Y, 1924, P 24 ATF JAK IND OCT
[9]   NIST-F1: recent improvements and accuracy evaluations [J].
Heavner, TP ;
Jefferts, SR ;
Donley, EA ;
Shirley, JH ;
Parker, TE .
METROLOGIA, 2005, 42 (05) :411-422
[10]   Measuring the frequency of a Sr optical lattice clock using a 120 km coherent optical transfer [J].
Hong, F. -L. ;
Musha, M. ;
Takamoto, M. ;
Inaba, H. ;
Yanagimachi, S. ;
Takamizawa, A. ;
Watabe, K. ;
Ikegami, T. ;
Imae, M. ;
Fujii, Y. ;
Amemiya, M. ;
Nakagawa, K. ;
Ueda, K. ;
Katori, H. .
OPTICS LETTERS, 2009, 34 (05) :692-694