A high-throughput liquid chromatography tandem mass spectrometry method for the comparative determination of fluticasone propionate by reversed-phase liquid chromatography and capillary electrophoresis methods in pharmaceutical nasal sprays

被引:8
|
作者
Sangoi, Maximiliano da Silva [1 ]
Wrasse, Micheli [2 ]
D'Avila, Felipe Bianchini [2 ]
Bernardi, Raquel Martini [1 ]
de Oliveira, Paulo Renato [3 ]
Dalmora, Sergio Luiz [2 ]
Bueno Rolim, Clarice Madalena [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Fac Pharm, BR-90610000 Porto Alegre, RS, Brazil
[2] Univ Fed Santa Maria, Dept Ind Pharm, BR-97105900 Santa Maria, RS, Brazil
[3] Univ Fed Santa Catarina, Dept Pharmaceut Sci, BR-88040900 Florianopolis, SC, Brazil
关键词
fluticasone propionate; tandem mass spectrometry; liquid chromatography; capillary electrophoresis; validation; ANALYTICAL METHOD VALIDATION; LC-MS/MS METHOD; HUMAN PLASMA; ALLERGIC RHINITIS; CORTICOSTEROIDS; QUANTIFICATION; FORMULATIONS; INTRANASAL; EXTRACTION; ASTHMA;
D O I
10.1255/ejms.1044
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A simple, specific, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of fluticasone propionate (FP) in pharmaceutical formulations was developed and validated using deflazacort as internal standard (IS). The LC-MS/MS method was carried out on a C(8) column (50 mm) with a mobile phase consisted of methanol:water (95:5, v/v)-100 mM formic acid-50 mM ammonium acetate (90:5:5,v/v/v). The mass spectrometry method was performed employing positive atmospheric pressure chemical ionization technique, operating in multiple reaction monitoring mode. The chromatographic separation was obtained within 1.5 min and it was linear in the concentration range of 10-1000 ng mL(-1). Moreover, method validation demonstrates acceptable results for the specificity, accuracy, precision and robustness. The proposed method was successfully applied for the quantitative analysis of FP nasal sprays and the results were compared to validated liquid chromatography and capillary electrophoresis methods with photodiode array detectors showing non-significant difference (P > 0.05).
引用
收藏
页码:723 / 730
页数:8
相关论文
共 50 条
  • [41] Simultaneous determination of clenbuterol, salbutamol and ractopamine in milk by reversed-phase liquid chromatography tandem mass spectrometry with isotope dilution
    Li, Cun
    Wu, Yin-Liang
    Yang, Ting
    Zhang, Yan
    Huang-Fu, Wei-Guo
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (50) : 7873 - 7877
  • [42] Determination of neomycin and related substances in pharmaceutical preparations by reversed-phase high performance liquid chromatography with mass spectrometry and charged aerosol detection
    Stypulkowska, K.
    Blazewicz, A.
    Fijalek, Z.
    Warowna-Grzeskiewicz, M.
    Srebrzynska, K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 76 : 207 - 214
  • [43] Fully automatable two-dimensional reversed-phase capillary liquid chromatography with online tandem mass spectrometry for shotgun proteomics
    Siu, S. O.
    Lam, Maggie P. Y.
    Lau, Edward
    Kong, Ricky P. W.
    Lee, Simon M. Y.
    Chu, Ivan K.
    PROTEOMICS, 2011, 11 (11) : 2308 - 2319
  • [44] Characterization of recombinant cytokine fragments using isotachophoresis-capillary zone electrophoresis, reversed-phase high performance liquid chromatography, and mass spectrometry
    Gysler, J
    Helk, B
    Dambacher, S
    Tjaden, UR
    van der Greef, J
    PHARMACEUTICAL RESEARCH, 1999, 16 (05) : 695 - 701
  • [45] A high-throughput liquid chromatography-tandem mass spectrometry method for simultaneous determination of direct oral anticoagulants in human plasma
    Zidekova, Nela
    Prso, Kristian
    Brisudova, Kristina
    Babalova, Lucia
    Bolek, Tomas
    Sivak, Stefan
    Kurca, Egon
    Mokry, Juraj
    Samos, Matej
    Nosal, Vladimir
    Kertys, Martin
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (13)
  • [46] Characterization of Recombinant Cytokine Fragments Using Isotachophoresis-Capillary Zone Electrophoresis, Reversed-Phase High Performance Liquid Chromatography, and Mass Spectrometry
    J. Gysler
    B. Helk
    S. Dambacher
    U. R. Tjaden
    J. van der Greef
    Pharmaceutical Research, 1999, 16 : 695 - 701
  • [47] High-throughput determination of neonicotinoid insecticides in pollen and nectar using liquid chromatography with tandem mass spectrometry detection
    Warnick, Joe
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [48] High-throughput quantification for a drug mixture in rat plasma -: a comparison of Ultra PerformanceTM liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry
    Yu, K
    Little, D
    Plumb, R
    Smith, B
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (04) : 544 - 552
  • [49] Microchip-based reversed-phase liquid chromatography tandem mass spectrometry platform for protein analysis
    Liang Yu
    Wu Ci
    Dai Zhongpeng
    Liang Zuocheng
    Liang Zhen
    Zhang Lihua
    Zhang Yukui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (06) : 469 - 474
  • [50] Chiral analysis by online coupling of reversed-phase liquid chromatography to gas chromatography and mass spectrometry
    Barba, Carmen
    Martinez, Rosa M.
    Calvo, Marta M.
    Santa-Maria, Guillermo
    Herraiz, Marta
    CHIRALITY, 2012, 24 (05) : 420 - 426