A high-throughput liquid chromatography tandem mass spectrometry method for the comparative determination of fluticasone propionate by reversed-phase liquid chromatography and capillary electrophoresis methods in pharmaceutical nasal sprays

被引:8
|
作者
Sangoi, Maximiliano da Silva [1 ]
Wrasse, Micheli [2 ]
D'Avila, Felipe Bianchini [2 ]
Bernardi, Raquel Martini [1 ]
de Oliveira, Paulo Renato [3 ]
Dalmora, Sergio Luiz [2 ]
Bueno Rolim, Clarice Madalena [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Fac Pharm, BR-90610000 Porto Alegre, RS, Brazil
[2] Univ Fed Santa Maria, Dept Ind Pharm, BR-97105900 Santa Maria, RS, Brazil
[3] Univ Fed Santa Catarina, Dept Pharmaceut Sci, BR-88040900 Florianopolis, SC, Brazil
关键词
fluticasone propionate; tandem mass spectrometry; liquid chromatography; capillary electrophoresis; validation; ANALYTICAL METHOD VALIDATION; LC-MS/MS METHOD; HUMAN PLASMA; ALLERGIC RHINITIS; CORTICOSTEROIDS; QUANTIFICATION; FORMULATIONS; INTRANASAL; EXTRACTION; ASTHMA;
D O I
10.1255/ejms.1044
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A simple, specific, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of fluticasone propionate (FP) in pharmaceutical formulations was developed and validated using deflazacort as internal standard (IS). The LC-MS/MS method was carried out on a C(8) column (50 mm) with a mobile phase consisted of methanol:water (95:5, v/v)-100 mM formic acid-50 mM ammonium acetate (90:5:5,v/v/v). The mass spectrometry method was performed employing positive atmospheric pressure chemical ionization technique, operating in multiple reaction monitoring mode. The chromatographic separation was obtained within 1.5 min and it was linear in the concentration range of 10-1000 ng mL(-1). Moreover, method validation demonstrates acceptable results for the specificity, accuracy, precision and robustness. The proposed method was successfully applied for the quantitative analysis of FP nasal sprays and the results were compared to validated liquid chromatography and capillary electrophoresis methods with photodiode array detectors showing non-significant difference (P > 0.05).
引用
收藏
页码:723 / 730
页数:8
相关论文
共 50 条
  • [41] Determination of eight artificial sweeteners and common Stevia rebaudiana glycosides in non-alcoholic and alcoholic beverages by reversed-phase liquid chromatography coupled with tandem mass spectrometry
    Kubica, Pawel
    Namiesnik, Jacek
    Wasik, Andrzej
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (05) : 1505 - 1512
  • [42] A high-throughput method for liquid chromatography-tandem mass spectrometry determination of plasma alkylresorcinols, biomarkers of whole grain wheat and rye intake
    Ross, Alastair B.
    Svelander, Cecilia
    Savolainen, Otto I.
    Lind, Mads Vendelbo
    Kirwan, John P.
    Breton, Isabelle
    Godin, Jean-Philippe
    Sandberg, Ann-Sofie
    ANALYTICAL BIOCHEMISTRY, 2016, 499 : 1 - 7
  • [43] Determination of creatinine-related molecules in saliva by reversed-phase liquid chromatography with tandem mass spectrometry and the evaluation of hemodialysis in chronic kidney disease patients
    Suzuki, Mayu
    Furuhashi, Mitsuyoshi
    Sesoko, Shogo
    Kosuge, Kazuhiro
    Maeda, Toshio
    Todoroki, Kenichiro
    Inoue, Koichi
    Min, Jun Zhe
    Toyo'oka, Toshimasa
    ANALYTICA CHIMICA ACTA, 2016, 911 : 92 - 99
  • [44] Determination of aflatoxins in hazelnuts by various sample preparation methods and liquid chromatography-tandem mass spectrometry
    Bacaloni, Alessandro
    Cavaliere, Chiara
    Cucci, Francesca
    Foglia, Patrizia
    Samperi, Roberto
    Lagana, Aldo
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1179 (02) : 182 - 189
  • [45] Development of a high-throughput liquid chromatography-tandem mass spectrometry platform for the determination of intact natriuretic peptides in human plasma
    Lenzi, Alessio
    De Cristofaro, Mariano
    Biagini, Denise
    Ghimenti, Silvia
    Armenia, Silvia
    Pugliese, Nicola R.
    Masi, Stefano
    Di Francesco, Fabio
    Lomonaco, Tommaso
    TALANTA, 2024, 275
  • [46] High-throughput determination of pesticide residues in food commodities by use of ultra-performance liquid chromatography–tandem mass spectrometry
    A. Garrido Frenich
    J. L. Martínez Vidal
    E. Pastor-Montoro
    R. Romero-González
    Analytical and Bioanalytical Chemistry, 2008, 390 : 947 - 959
  • [47] Determination of N-nitrosamines in cosmetic products by vortex-assisted reversed-phase dispersive liquid-liquid microextraction and liquid chromatography with mass spectrometry
    Miralles, Pablo
    Chisvert, Alberto
    Salvador, Amparo
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (15) : 3143 - 3151
  • [48] High-pH mobile phase in reversed-phase liquid chromatography-tandem mass spectrometry to improve the separation efficiency of aminoglycoside isomers
    Nakano, Yuta
    Sakamaki, Hiroshi
    Tasaki-Handa, Yuiko
    Saito, Shingo
    ANALYTICAL SCIENCES, 2024, 40 (03) : 375 - 384
  • [49] Quantification of corticosteroids in bovine urine using selective solid phase extraction and reversed-phase liquid chromatography/tandem mass spectrometry
    Tolgyesi, Adam
    Sharma, Virender K.
    Kovacsics, Lorena
    Fekete, Jeno
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1471 - 1479
  • [50] Determination of diallyl disulfide in garlic by reversed-phase high performance liquid chromatography
    Wan, Xiaolong
    Polyakova, Yulia
    Row, Kyung Ho
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2007, 20 (05) : 442 - 447