A high-throughput liquid chromatography tandem mass spectrometry method for the comparative determination of fluticasone propionate by reversed-phase liquid chromatography and capillary electrophoresis methods in pharmaceutical nasal sprays

被引:8
|
作者
Sangoi, Maximiliano da Silva [1 ]
Wrasse, Micheli [2 ]
D'Avila, Felipe Bianchini [2 ]
Bernardi, Raquel Martini [1 ]
de Oliveira, Paulo Renato [3 ]
Dalmora, Sergio Luiz [2 ]
Bueno Rolim, Clarice Madalena [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Fac Pharm, BR-90610000 Porto Alegre, RS, Brazil
[2] Univ Fed Santa Maria, Dept Ind Pharm, BR-97105900 Santa Maria, RS, Brazil
[3] Univ Fed Santa Catarina, Dept Pharmaceut Sci, BR-88040900 Florianopolis, SC, Brazil
关键词
fluticasone propionate; tandem mass spectrometry; liquid chromatography; capillary electrophoresis; validation; ANALYTICAL METHOD VALIDATION; LC-MS/MS METHOD; HUMAN PLASMA; ALLERGIC RHINITIS; CORTICOSTEROIDS; QUANTIFICATION; FORMULATIONS; INTRANASAL; EXTRACTION; ASTHMA;
D O I
10.1255/ejms.1044
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A simple, specific, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of fluticasone propionate (FP) in pharmaceutical formulations was developed and validated using deflazacort as internal standard (IS). The LC-MS/MS method was carried out on a C(8) column (50 mm) with a mobile phase consisted of methanol:water (95:5, v/v)-100 mM formic acid-50 mM ammonium acetate (90:5:5,v/v/v). The mass spectrometry method was performed employing positive atmospheric pressure chemical ionization technique, operating in multiple reaction monitoring mode. The chromatographic separation was obtained within 1.5 min and it was linear in the concentration range of 10-1000 ng mL(-1). Moreover, method validation demonstrates acceptable results for the specificity, accuracy, precision and robustness. The proposed method was successfully applied for the quantitative analysis of FP nasal sprays and the results were compared to validated liquid chromatography and capillary electrophoresis methods with photodiode array detectors showing non-significant difference (P > 0.05).
引用
收藏
页码:723 / 730
页数:8
相关论文
共 50 条
  • [31] Minimization of carryover for high-throughput liquid chromatography with tandem mass spectrometry analysis of 14 mycotoxins in corn grits
    Tamura, Masayoshi
    Matsumoto, Keiko
    Watanabe, Jun
    Iida, Junko
    Nagatomi, Yasushi
    Mochizuki, Naoki
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (13) : 1552 - 1560
  • [32] Simultaneous determination of 15 top-prescribed pharmaceuticals and their metabolites in influent wastewater by reversed-phase liquid chromatography coupled to tandem mass spectrometry
    Tarcomnicu, Isabela
    van Nuijs, Alexander L. N.
    Simons, Ward
    Bervoets, Lieven
    Blust, Ronny
    Jorens, Philippe G.
    Neels, Hugo
    Covaci, Adrian
    TALANTA, 2011, 83 (03) : 795 - 803
  • [33] Determination of ochratoxin A in wine by liquid chromatography tandem mass spectrometry after combined anion-exchange/reversed-phase clean-up
    M. Reinsch
    A. Töpfer
    A. Lehmann
    I. Nehls
    Analytical and Bioanalytical Chemistry, 2005, 381 : 1592 - 1595
  • [34] DETERMINATION OF SULFUR IN PHARMACEUTICAL PREPARATIONS USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KUROSAKA, K
    KUCHIKI, A
    NAKAGAWA, H
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1991, 39 (08) : 2138 - 2139
  • [35] A liquid chromatography - Tandem mass spectrometry method for determination of ocrelizumab in serum of patients with multiple sclerosis
    Matlak, Patrik
    Brozmanova, Hana
    Sistik, Pavel
    Moskorova, Denisa
    Kacirova, Ivana
    Hradilek, Pavel
    Grundmann, Milan
    TALANTA, 2025, 283
  • [36] Analysis of Sulfonamides by Liquid Chromatography Mass Spectrometry and Capillary Electrophoresis Combing with Voltage-Assisted Liquid-Phase Microextraction
    Wang, Mi-Hung
    Chang, Heng-Wei
    Wang, Shu-Ping
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (12) : 1479 - 1483
  • [37] Greening Reversed-Phase Liquid Chromatography Methods Using Alternative Solvents for Pharmaceutical Analysis
    Yabre, Moussa
    Ferey, Ludivine
    Some, Issa Touridomon
    Gaudin, Karen
    MOLECULES, 2018, 23 (05):
  • [38] High-throughput determination of urinary hexosamines for diagnosis of mucopolysaccharidoses by capillary electrophoresis and high-performance liquid chromatography
    Coppa, Giovanni V.
    Galeotti, Fabio
    Zampini, Lucia
    Maccari, Francesca
    Galeazzi, Tiziana
    Padelia, Lucia
    Santoro, Lucia
    Gabrielli, Orazio
    Volpi, Nicola
    ANALYTICAL BIOCHEMISTRY, 2011, 411 (01) : 32 - 42
  • [39] A liquid chromatography and tandem mass spectrometry method for the determination of potential biomarkers of cardiovascular disease
    Magiera, Sylwia
    Baranowska, Irena
    Kusa, Jacek
    Baranowski, Jacek
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 919 : 20 - 29
  • [40] Nanoscale reversed-phase liquid chromatography–mass spectrometry of permethylated N-glycans
    Ilja Ritamo
    Jarkko Räbinä
    Suvi Natunen
    Leena Valmu
    Analytical and Bioanalytical Chemistry, 2013, 405 : 2469 - 2480