A high-throughput liquid chromatography tandem mass spectrometry method for the comparative determination of fluticasone propionate by reversed-phase liquid chromatography and capillary electrophoresis methods in pharmaceutical nasal sprays

被引:8
|
作者
Sangoi, Maximiliano da Silva [1 ]
Wrasse, Micheli [2 ]
D'Avila, Felipe Bianchini [2 ]
Bernardi, Raquel Martini [1 ]
de Oliveira, Paulo Renato [3 ]
Dalmora, Sergio Luiz [2 ]
Bueno Rolim, Clarice Madalena [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Fac Pharm, BR-90610000 Porto Alegre, RS, Brazil
[2] Univ Fed Santa Maria, Dept Ind Pharm, BR-97105900 Santa Maria, RS, Brazil
[3] Univ Fed Santa Catarina, Dept Pharmaceut Sci, BR-88040900 Florianopolis, SC, Brazil
关键词
fluticasone propionate; tandem mass spectrometry; liquid chromatography; capillary electrophoresis; validation; ANALYTICAL METHOD VALIDATION; LC-MS/MS METHOD; HUMAN PLASMA; ALLERGIC RHINITIS; CORTICOSTEROIDS; QUANTIFICATION; FORMULATIONS; INTRANASAL; EXTRACTION; ASTHMA;
D O I
10.1255/ejms.1044
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A simple, specific, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of fluticasone propionate (FP) in pharmaceutical formulations was developed and validated using deflazacort as internal standard (IS). The LC-MS/MS method was carried out on a C(8) column (50 mm) with a mobile phase consisted of methanol:water (95:5, v/v)-100 mM formic acid-50 mM ammonium acetate (90:5:5,v/v/v). The mass spectrometry method was performed employing positive atmospheric pressure chemical ionization technique, operating in multiple reaction monitoring mode. The chromatographic separation was obtained within 1.5 min and it was linear in the concentration range of 10-1000 ng mL(-1). Moreover, method validation demonstrates acceptable results for the specificity, accuracy, precision and robustness. The proposed method was successfully applied for the quantitative analysis of FP nasal sprays and the results were compared to validated liquid chromatography and capillary electrophoresis methods with photodiode array detectors showing non-significant difference (P > 0.05).
引用
收藏
页码:723 / 730
页数:8
相关论文
共 50 条
  • [31] High-throughput method for the determination of nitroimidazoles in muscle samples by liquid chromatography coupled to mass spectrometry
    Rubies, A.
    Sans, G.
    Kumar, P.
    Granados, M.
    Companyo, R.
    Centrich, F.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (15) : 4411 - 4421
  • [32] Development of a high-throughput method for the determination of ethosuximide in human plasma by liquid chromatography mass spectrometry
    Bhatt, Mitesh
    Shah, Sanjay
    Shivprakash
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1605 - 1610
  • [33] High-throughput plasma docetaxel quantification by liquid chromatography-tandem mass spectrometry
    Corona, Giuseppe
    Elia, Caterina
    Casetta, Bruno
    Frustaci, Sergio
    Toffoli, Giuseppe
    CLINICA CHIMICA ACTA, 2011, 412 (3-4) : 358 - 364
  • [34] Validation of a high-throughput liquid chromatography-tandem mass spectrometry method for urinary cortisol and cortisone
    Taylor, RL
    Machacek, D
    Singh, RJ
    CLINICAL CHEMISTRY, 2002, 48 (09) : 1511 - 1519
  • [35] A fully automated high-throughput liquid chromatography tandem mass spectrometry method for measuring creatinine in urine
    Zahoor, Neelam
    Danilenko, Uliana
    Vesper, Hubert W.
    CLINICAL MASS SPECTROMETRY, 2019, 11 : 1 - 7
  • [36] High-throughput multiclass method for antibiotic residue analysis by liquid chromatography-tandem mass spectrometry
    Chico, J.
    Rubies, A.
    Centrich, F.
    Companyo, R.
    Prat, M. D.
    Granados, M.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) : 189 - 199
  • [37] Assessment of antibody fragmentation by reversed-phase liquid chromatography and mass spectrometry
    Liu, Hongcheng
    Gaza-Bulseco, Georgeen
    Lundell, Edwin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (01): : 13 - 23
  • [38] Robust Capillary- and Micro-Flow Liquid Chromatography-Tandem Mass Spectrometry Methods for High-Throughput Proteome Profiling
    Sui, Xintong
    Wu, Qiong
    Cui, Xiaozhen
    Wang, Xi
    Zhang, Luobin
    Deng, Nan
    Bian, Yangyang
    Xu, Ruilian
    Tian, Ruijun
    JOURNAL OF PROTEOME RESEARCH, 2022, : 2472 - 2480
  • [39] Reversed-Phase Liquid Chromatography-Quadrupole-Time-of-Flight Mass Spectrometry for High-Throughput Molecular Profiling of Sea Cucumber Cerebrosides
    Jia, Zicai
    Cong, Peixu
    Zhang, Hongwei
    Song, Yu
    Li, Zhaojie
    Xu, Jie
    Xue, Changhu
    LIPIDS, 2015, 50 (07) : 667 - 679
  • [40] Determination of ten hexabromocyclododecane diastereoisomers using two coupled reversed-phase columns and liquid chromatography/tandem mass spectrometry
    Han, Qian
    Song, Han
    Gao, Shutao
    Zeng, Xiangying
    Yu, Zhiqiang
    Yu, Yunjiang
    Sheng, Guoying
    Fu, Jiamo
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (13) : 1473 - 1478