A high-throughput liquid chromatography tandem mass spectrometry method for the comparative determination of fluticasone propionate by reversed-phase liquid chromatography and capillary electrophoresis methods in pharmaceutical nasal sprays

被引:8
|
作者
Sangoi, Maximiliano da Silva [1 ]
Wrasse, Micheli [2 ]
D'Avila, Felipe Bianchini [2 ]
Bernardi, Raquel Martini [1 ]
de Oliveira, Paulo Renato [3 ]
Dalmora, Sergio Luiz [2 ]
Bueno Rolim, Clarice Madalena [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Fac Pharm, BR-90610000 Porto Alegre, RS, Brazil
[2] Univ Fed Santa Maria, Dept Ind Pharm, BR-97105900 Santa Maria, RS, Brazil
[3] Univ Fed Santa Catarina, Dept Pharmaceut Sci, BR-88040900 Florianopolis, SC, Brazil
关键词
fluticasone propionate; tandem mass spectrometry; liquid chromatography; capillary electrophoresis; validation; ANALYTICAL METHOD VALIDATION; LC-MS/MS METHOD; HUMAN PLASMA; ALLERGIC RHINITIS; CORTICOSTEROIDS; QUANTIFICATION; FORMULATIONS; INTRANASAL; EXTRACTION; ASTHMA;
D O I
10.1255/ejms.1044
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A simple, specific, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of fluticasone propionate (FP) in pharmaceutical formulations was developed and validated using deflazacort as internal standard (IS). The LC-MS/MS method was carried out on a C(8) column (50 mm) with a mobile phase consisted of methanol:water (95:5, v/v)-100 mM formic acid-50 mM ammonium acetate (90:5:5,v/v/v). The mass spectrometry method was performed employing positive atmospheric pressure chemical ionization technique, operating in multiple reaction monitoring mode. The chromatographic separation was obtained within 1.5 min and it was linear in the concentration range of 10-1000 ng mL(-1). Moreover, method validation demonstrates acceptable results for the specificity, accuracy, precision and robustness. The proposed method was successfully applied for the quantitative analysis of FP nasal sprays and the results were compared to validated liquid chromatography and capillary electrophoresis methods with photodiode array detectors showing non-significant difference (P > 0.05).
引用
收藏
页码:723 / 730
页数:8
相关论文
共 50 条
  • [1] Comparison of capillary electrophoresis and reversed-phase liquid chromatography methodologies for determination of diazepam in pharmaceutical tablets
    Prado, MSA
    Steppe, M
    Tavares, MFM
    Kedor-Hackmann, ERM
    Santoro, MIRM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (02) : 273 - 279
  • [2] High-throughput chiral liquid chromatography/tandem mass spectrometry
    Bakhtiar, R
    Tse, FLS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (13) : 1128 - 1135
  • [3] Determination of Catecholamines by Capillary Electrophoresis and Reversed-Phase High-Performance Liquid Chromatography
    L. A. Kartsova
    A. A. Sidorova
    V. A. Kazakov
    E. A. Bessonova
    A. Ya. Yashin
    Journal of Analytical Chemistry, 2004, 59 : 737 - 741
  • [4] Determination of catecholamines by capillary electrophoresis and reversed-phase high-performance liquid chromatography
    Kartsova, LA
    Sidorova, AA
    Kazakov, VA
    Bessonova, EA
    Yashin, AY
    JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 59 (08) : 737 - 741
  • [5] Validation of liquid chromatography and liquid chromatography/tandem mass spectrometry methods for the determination of etoricoxib in pharmaceutical formulations
    Brum Jr., Liberato
    Fronza, Marcio
    Ceni, Danieli Catia
    Barth, Thiago
    Dalmora, Sergio Luiz
    Journal of AOAC International, 1600, 89 (05): : 1268 - 1275
  • [6] Validation of liquid chromatography and liquid chromatography/tandem mass determination of etoricoxib in spectrometry methods for the pharmaceutical formulations
    Brum, Liberato, Jr.
    Fronza, Marco
    Ceni, Danieli Catia
    Barth, Thiago
    Dalmora, Sergio Luiz
    JOURNAL OF AOAC INTERNATIONAL, 2006, 89 (05) : 1268 - 1275
  • [7] Determination of Diquat Residues in Potato Using Reversed-Phase Liquid Chromatography with Tandem Mass Spectrometry
    Attallah, Emad R.
    Soliman, Mostafa
    Abo-Aly, Mohamed M.
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (03) : 789 - 795
  • [8] Determination of urine catecholamines and metanephrines by reversed-phase liquid chromatography-tandem mass spectrometry
    CHEUK Man-Yung
    LO Yun-Chuen
    POON Wing-Tat
    色谱, 2017, (10) : 1042 - 1047
  • [9] Identification and relative quantification of peptides by capillary reversed-phase liquid chromatography-tandem mass spectrometry
    Li Xin
    Jiang Xinning
    Zou Hanfa
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (02) : 189 - 194
  • [10] Comparing nanoflow reversed-phase liquid chromatography-tandem mass spectrometry and capillary zone electrophoresis-tandem mass spectrometry for top-down proteomics
    McCool, Elijah N.
    Sun, Liangliang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (08) : 878 - 886