Extended depth of focus lens implantation after radial keratotomy

被引:13
作者
Baartman, Brandon J. [1 ]
Karpuk, Kayla [1 ]
Eichhorn, Bradley [2 ]
Ferguson, Tanner J. [2 ]
Sudhagoni, Ramu G. [3 ]
Berdahl, John P. [1 ]
Thompson, Vance M. [1 ]
机构
[1] Vance Thompson Vis, 3101 W 57th St, Sioux Falls, SD 57108 USA
[2] Univ South Dakota, Sch Med, Vermillion, SD USA
[3] Univ South Dakota, Publ Hlth Dept, Sch Hlth Sci, Vermillion, SD USA
来源
CLINICAL OPHTHALMOLOGY | 2019年 / 13卷
关键词
radial keratotomy; cataract; intraocular lens; INTRAOCULAR-LENS; CONTRAST SENSITIVITY; CORNEAL ABERRATIONS; REFRACTIVE SURGERY; POWER CALCULATION; CATARACT-SURGERY; VISION; DEHISCENCE; OUTCOMES; RANGE;
D O I
10.2147/OPTH.S208550
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To identify the visual performance of radial keratotomy (RK) patients that have undergone cataract surgery with implantation of an extended depth of focus (EDOF) intraocular lens (IOL). Design: Retrospective chart review with questionnaire. Methods: Medical charts of patients with a history of RK that had undergone phacoemulsification with implantation of the Tecnis Symfony IOL (J&J Vision) were reviewed. Data collected included preoperative demographics, number of RK incisions, pupil size, and preoperative visual acuity and manifest refraction. Primary outcome measures of the study included postoperative uncorrected distance visual acuity (UCVA) and manifest refraction spherical equivalent (SE) at each follow-up visit. Secondary outcomes included results from a telephone questionnaire assessing visual performance and satisfaction. Results: Twenty-four eyes of 12 patients were included. UCVA improved from an average Snellen equivalent 20/73 preoperatively to 20/33 at an average final follow-up of 6 months (P=0.0011), while average manifest SE improved from +1.68 D to -0.18 D (P<0.0001). At final follow-up, 15 of 24 eyes (62.5%) were at or within 0.5 D of target refraction, while 20 of 24 eyes (83.3%) were at or within 1.0 D. In total, 79% of eyes (19 of 24) had UCVA of 20/40 or better at distance. In the survey, 78% of patients reported satisfaction with their vision after surgery and 44% of patients reported being spectacle free for all tasks. Conclusions: An EDOF lens implant can produce good visual outcomes and satisfaction in patients with a history of RK.
引用
收藏
页码:1401 / 1408
页数:8
相关论文
共 24 条
[1]   Higher-Order Aberrations After Cyclopentolate, Tropicamide, and Artificial Tear Drops Application in Normal Eyes [J].
Amirshekarizadeh, Negin ;
Hashemi, Hassan ;
Jafarzadehpur, Ebrahim ;
Mirzajani, Ali ;
Yekta, Abbasali ;
Khabazkhoob, Mehdi .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 (02) :109-112
[2]   Corneal aberrations increase with the magnitude of radial keratotomy refractive correction [J].
Applegate, RA ;
Hilmantel, G ;
Howland, HC .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (09) :585-589
[3]   Corneal aberrations and visual performance after radial keratotomy [J].
Applegate, RA ;
Howland, HC ;
Sharp, RP ;
Cottingham, AJ ;
Yee, RW .
JOURNAL OF REFRACTIVE SURGERY, 1998, 14 (04) :397-407
[4]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[5]   Analysis of intraocular lens power calculation in post-radial keratotomy eyes [J].
Chen, L ;
Mannis, MJ ;
Salz, JJ ;
Garcia-Ferrer, FJ ;
Ge, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01) :65-70
[6]   Delayed radial keratotomy dehiscence following uneventful phacoemulsification cataract surgery [J].
Day, A. ;
Seward, H. .
EYE, 2007, 21 (06) :886-887
[7]   Evaluation of the American Society of Cataract and Refractive Surgery intraocular lens calculator for eyes with prior radial keratotomy [J].
DeMill, David L. ;
Hsu, Maylon ;
Moshirfar, Majid .
CLINICAL OPHTHALMOLOGY, 2011, 5 :1243-1247
[8]   Dehiscence of radial keratotomy incision during phacoemulsification [J].
Freeman, M ;
Kumar, V ;
Ramanathan, US ;
O'Neill, E .
EYE, 2004, 18 (01) :101-103
[9]   Intraocular Lens Power Selection after Radial Keratotomy [J].
Geggel, Harry S. .
OPHTHALMOLOGY, 2015, 122 (05) :897-902
[10]   Comparison of far and near contrast sensitivity in patients symmetrically implanted with multifocal and monofocal IOLs [J].
Gil, Miguel A. ;
Varon, Consuelo ;
Cardona, Genis ;
Vega, Fidel ;
Buil, Jose A. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (01) :44-52