摘要
In this study, a fast, simple and efficient ultrasound-assisted emulsification microextraction (USAEME) method was successfully developed based on applying low density organic solvents. Fourteen microliters of toluene was injected slowly into a 12 mL home-designed centrifuge glass vial containing an aqueous sample that was located inside the ultrasonic water bath. The formed emulsion was centrifuged and 2 mu L of separated toluene (about 4 mu L) was injected into a gas chromatographic system equipped with a flame ionization detector (CC-FID) for analysis. Some polycyclic aromatic hydrocarbons (PAHs) were selected as model compounds for developing the method and evaluating its performance and to compare the efficiency of the proposed method with previously reported techniques. Several factors influencing the emulsification, extraction and collection efficiency such as the nature and Volume of organic solvent, emulsification-extraction temperature, ionic strength and equilibrium and centrifugation times were investigated and optimized. Under the Optimum conditions, preconcentration factors (PFs) in a range of 1776-2714 were obtained. The performance of the proposed method was studied in terms of linear dynamic range (LDRs from 0.05 to 100 mu g L-1), linearity (R-2 >= 0.994), precision (repeatability: RSD% <= 7.9, reproducibility: RSD% <= 14.6) and extraction percents (59.2-90.5%). Limits of detection (LODs) in the range of 0.02-0.05 mu g L-1 were obtained for different PAHs. The applicability of the proposed method was evaluated by the extraction and determination of PAHs from several natural water samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:6673 / 6679
页数:7
相关论文
共 34 条
  • [1] [Anonymous], TRENDS ANAL CHEM
  • [2] MICROEXTRACTION BY DEMIXING FOR THE DETERMINATION OF VOLATILE COMPOUNDS IN AQUEOUS-SOLUTIONS
    CACHO, J
    FERREIRA, V
    FERNANDEZ, P
    [J]. ANALYTICA CHIMICA ACTA, 1992, 264 (02) : 311 - 317
  • [3] Surfactant cloud point extraction and preconcentration of organic compounds prior to chromatography and capillary electrophoresis
    Carabias-Martínez, R
    Rodríguez-Gonzalo, E
    Moreno-Cordero, B
    Pérez-Pavón, JL
    García-Pinto, C
    Laespada, EF
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) : 251 - 265
  • [4] Analysis of polycyclic aromatic hydrocarbons in wastewater treatment plant effluents using hollow fibre liquid-phase microextraction
    Charalabaki, M
    Psillakis, E
    Mantzavinos, D
    Kalogerakis, N
    [J]. CHEMOSPHERE, 2005, 60 (05) : 690 - 698
  • [5] Ultrasound-assisted preparation of liquid samples
    de Castro, M. D. Luque
    Priego-Capote, F.
    [J]. TALANTA, 2007, 72 (02) : 321 - 334
  • [6] Dean J.A., 2001, Lange's Handbook of Chemistry, V15
  • [7] DETERMINATION OF PESTICIDES IN AQUEOUS SAMPLES BY SOLID-PHASE MICROEXTRACTION IN-LINE COUPLED TO GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    EISERT, R
    LEVSEN, K
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (11) : 1119 - 1130
  • [8] Use of cloud point extraction methodology for the determination of PAHs priority pollutants in water samples by high-performance liquid chromatography with fluorescence detection and wavelength programming
    Ferrer, R
    Beltran, JL
    Guiteras, J
    [J]. ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) : 199 - 206
  • [9] Simple approach based on ultrasound-assisted emulsification-microextraction for determination of polibrominated flame retardants in water samples by gas chromatography-mass spectrometry
    Fontana, Ariel R.
    Wuilloud, RodolfoG.
    Martinez, Luis D.
    Altamirano, Jorgelina C.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (01) : 147 - 153
  • [10] Guidotti M, 1996, HRC-J HIGH RES CHROM, V19, P469, DOI 10.1002/jhrc.1240190812