Reduced graphene oxide-chitosan-aptamer interface as new platform for ultrasensitive detection of human epidermal growth factor receptor 2

被引:106
作者
Tabasi, Arezoo [1 ]
Noorbakhsh, Abdollah [1 ]
Sharifi, Ensiyeh [1 ]
机构
[1] Univ Isfahan, Dept Nanotechnol Engn, Fac Adv Sci & Technol, Esfahan 8174673441, Iran
关键词
Tumor marker; Human epidermal growth factor receptor 2; Aptamer; Reduced graphene oxide-chitosan; Biosensor; Modified electrode; CANCER BIOMARKER; HER2; NANOCOMPOSITE; APTASENSOR; DNA; IMMUNOSENSOR; FABRICATION; BIOSENSORS; DIAGNOSIS;
D O I
10.1016/j.bios.2017.04.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The present work describes an ultrasensitive electrochemical aptamer-based assay for detection of human epidermal growth factor receptor 2 protein (HER2) cancer biomarker as a model analyte. Results show that the reduced graphene oxide-chitosan (rGO-Chit) film as a suitable electrode material possesses great favorable properties including high homogeneity, good stability, large surface area and high fraction of amine groups as aptamer binding sites. Various steps of aptasensor fabrication were characterized using microscopic, energy dispersive X-ray spectroscopy (EDAX), Fourier transform infrared (FTIR) spectroscopy and electrochemical techniques. Using methylene blue (MB) as an electrochemical probe and differential pulse voltammetry (DPV) technique, two linear concentration ranges of 0.5-2 ng ml(-1) and 2-75 ng ml(-1) were obtained with a high sensitivity of 0.14 mu A ng(-1) ml and a very low detection limit of 0.21 ng ml(-1) (very lower than the clinical cutoff). The fabricated aptasensor showed excellent selectivity for detection of HER2 in complex matrix of human serum samples. The sensitive detection of HER2 can be attributed to the multiple signal amplification of MB during its accumulation to the modified electrode surface via both affinity interaction to aptamer molecules and electrostatic adsorption to the HER2 analyte as well as high charge transfer kinetic properties of the applied rGO-Chit film. The rapid and simple preparation of the proposed aptasensor as well as its high selectivity, stability and reproducibility provided a promising protocol for non-invasive diagnosis for various points of care application. The proposed aptasensor showed excellent analytical performance in comparison with current HER2 biosensors.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 33 条
  • [11] Biosensors for breast cancer diagnosis: A review of bioreceptors, biotransducers and signal amplification strategies
    Mittal, Sunil
    Kaur, Hardeep
    Gautam, Nandini
    Mantha, Anil K.
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 88 : 217 - 231
  • [12] Nanoelectrode ensembles as recognition platform for electrochemical immunosensors
    Mucelli, S. Pozzi
    Zamuner, M.
    Tormen, M.
    Stanta, G.
    Ugo, P.
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (12) : 1900 - 1903
  • [13] Planar optical waveguide-based biosensor for the quantitative detection of tumor markers
    Mukundan, Harshini
    Kubicek, Jessica Z.
    Holt, Alicia
    Shively, John E.
    Martinez, Jennifer S.
    Grace, Karen
    Grace, W. Kevin
    Swanson, Basil I.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (02): : 453 - 460
  • [14] Antifouling properties of reduced graphene oxide nanosheets for highly sensitive determination of insulin
    Noorbakhsh, Abdollah
    Alnajar, Ahmed Ismael Khaleel
    [J]. MICROCHEMICAL JOURNAL, 2016, 129 : 310 - 317
  • [15] DNA and PNA sensing on mercury and carbon electrodes by using methylene blue as an electrochemical label
    Ozkan, D
    Kara, P
    Kerman, K
    Meric, B
    Erdem, A
    Jelen, F
    Nielsen, PE
    Ozsoz, M
    [J]. BIOELECTROCHEMISTRY, 2002, 58 (01) : 119 - 126
  • [16] Nanoimmunoassay onto a screen printed electrode for HER2 breast cancer biomarker determination
    Patris, Stephanie
    De Pauw, Pieter
    Vandeput, Marie
    Huet, Joelle
    Van Antwerpen, Pierre
    Muyldermans, Serge
    Kauffmann, Jean-Michel
    [J]. TALANTA, 2014, 130 : 164 - 170
  • [17] Label-free capacitance based aptasensor platform for the detection of HER2/ErbB2 cancer biomarker in serum
    Qureshi, Anjum
    Gurbuz, Yasar
    Niazi, Javed H.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 1145 - 1151
  • [18] A label-free electrochemical affisensor for cancer marker detection: The case of HER2
    Ravalli, Andrea
    da Rocha, Carolina Gomes
    Yamanaka, Hideko
    Marrazza, Giovanna
    [J]. BIOELECTROCHEMISTRY, 2015, 106 : 268 - 275
  • [19] A Nanostructured Bifunctional platform for Sensing of Glucose Biomarker in Artificial Saliva: Synergy in hybrid Pt/Au surfaces
    Raymundo-Pereira, Paulo A.
    Shimizu, Flavio M.
    Coelho, Dyovani
    Piazzeta, Maria H. O.
    Gobbi, Angelo L.
    Machado, Sergio A. S.
    Oliveira, Osvaldo N., Jr.
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 86 : 369 - 376
  • [20] Cardiotoxic effects, or lack thereof, of anti-ErbB2 immunoagents
    Riccio, Gennaro
    Esposito, Giovanni
    Leoncini, Emanuela
    Contu, Riccardo
    Condorelli, Gianluigi
    Chiariello, Massimo
    Laccetti, Paolo
    Hrelia, Silvana
    D'Alessio, Giuseppe
    De Lorenzo, Claudia
    [J]. FASEB JOURNAL, 2009, 23 (09) : 3171 - 3178