Reduced graphene oxide-chitosan-aptamer interface as new platform for ultrasensitive detection of human epidermal growth factor receptor 2

被引:106
作者
Tabasi, Arezoo [1 ]
Noorbakhsh, Abdollah [1 ]
Sharifi, Ensiyeh [1 ]
机构
[1] Univ Isfahan, Dept Nanotechnol Engn, Fac Adv Sci & Technol, Esfahan 8174673441, Iran
关键词
Tumor marker; Human epidermal growth factor receptor 2; Aptamer; Reduced graphene oxide-chitosan; Biosensor; Modified electrode; CANCER BIOMARKER; HER2; NANOCOMPOSITE; APTASENSOR; DNA; IMMUNOSENSOR; FABRICATION; BIOSENSORS; DIAGNOSIS;
D O I
10.1016/j.bios.2017.04.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The present work describes an ultrasensitive electrochemical aptamer-based assay for detection of human epidermal growth factor receptor 2 protein (HER2) cancer biomarker as a model analyte. Results show that the reduced graphene oxide-chitosan (rGO-Chit) film as a suitable electrode material possesses great favorable properties including high homogeneity, good stability, large surface area and high fraction of amine groups as aptamer binding sites. Various steps of aptasensor fabrication were characterized using microscopic, energy dispersive X-ray spectroscopy (EDAX), Fourier transform infrared (FTIR) spectroscopy and electrochemical techniques. Using methylene blue (MB) as an electrochemical probe and differential pulse voltammetry (DPV) technique, two linear concentration ranges of 0.5-2 ng ml(-1) and 2-75 ng ml(-1) were obtained with a high sensitivity of 0.14 mu A ng(-1) ml and a very low detection limit of 0.21 ng ml(-1) (very lower than the clinical cutoff). The fabricated aptasensor showed excellent selectivity for detection of HER2 in complex matrix of human serum samples. The sensitive detection of HER2 can be attributed to the multiple signal amplification of MB during its accumulation to the modified electrode surface via both affinity interaction to aptamer molecules and electrostatic adsorption to the HER2 analyte as well as high charge transfer kinetic properties of the applied rGO-Chit film. The rapid and simple preparation of the proposed aptasensor as well as its high selectivity, stability and reproducibility provided a promising protocol for non-invasive diagnosis for various points of care application. The proposed aptasensor showed excellent analytical performance in comparison with current HER2 biosensors.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 33 条
  • [1] An Electrochemical Immunoassay for HER2 Detection
    Al-Khafaji, Q. A. M.
    Harris, M.
    Tombelli, S.
    Laschi, S.
    Turner, A. P. F.
    Mascini, M.
    Marrazza, G.
    [J]. ELECTROANALYSIS, 2012, 24 (04) : 735 - 742
  • [2] A novel antibody-antigen based impedimetric immunosensor for low level detection of HER2 in serum samples of breast cancer patients via modification of a gold nanoparticles decorated multiwall carbon nanotube-ionic liquid electrode
    Arkan, Elham
    Saber, Reza
    Karimi, Ziba
    Shamsipur, Mojtaba
    [J]. ANALYTICA CHIMICA ACTA, 2015, 874 : 66 - 74
  • [3] Electrochemical detection of HER2 using single stranded DNA aptamer modified gold nanoparticles electrode
    Chun, Limin
    Kim, Sung-Eun
    Cho, Misuk
    Choe, Woo-seok
    Nam, Jaedo
    Lee, Daniel W.
    Lee, Youngkwan
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 : 446 - 450
  • [4] Chitosan-graphene oxide based aptasensor for the impedimetric detection of lysozyme
    Erdem, Arzurn
    Eksin, Ece
    Muti, Mihrican
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 115 : 205 - 211
  • [5] Clinical utility of serum HER2/neu in monitoring and prediction of progression-free survival in metastatic breast cancer patients treated with trastuzumab-based therapies
    Esteva, FJ
    Cheli, CD
    Fritsche, H
    Fornier, M
    Slamon, D
    Thiel, RP
    Luftner, D
    Ghani, F
    [J]. BREAST CANCER RESEARCH, 2005, 7 (04) : R436 - R443
  • [6] In Vitro Selection of RNA Aptamer and Specific Targeting of ErbB2 in Breast Cancer Cells
    Kim, Mee Young
    Jeong, Sunjoo
    [J]. NUCLEIC ACID THERAPEUTICS, 2011, 21 (03) : 173 - 178
  • [7] Aptamer-based nanobiosensors
    Kim, Yeon Seok
    Raston, Nurul Hanun Ahmad
    Gu, Man Bock
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 76 : 2 - 19
  • [8] Recent advances in graphene-based biosensors
    Kuila, Tapas
    Bose, Saswata
    Khanra, Partha
    Mishra, Ananta Kumar
    Kim, Nam Hoon
    Lee, Joong Hee
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (12) : 4637 - 4648
  • [9] Lakshmi P. T. V., 2010, BIOINFORM SEQ ANAL, V2, P75
  • [10] Electrochemical immunosensor for the analysis of the breast cancer biomarker HER2 ECD
    Marques, Raquel C. B.
    Viswanathan, Subramanian
    Nouws, Henri P. A.
    Delerue-Matos, Cristina
    Begona Gonzalez-Garcia, M.
    [J]. TALANTA, 2014, 129 : 594 - 599