Evaluation of a commercial three-dimensional electron beam treatment planning system

被引:20
|
作者
Ding, GX
Cygler, JE
Zhang, GG
Yu, MK
机构
[1] British Columbia Canc Agcy, Fraser Valley Canc Ctr, Surrey, BC V3V 1Z2, Canada
[2] Ottawa Reg Canc Ctr, Dept Phys Med, Ottawa, ON K1Y 4K7, Canada
[3] Natl Res Council Canada, Ottawa, ON, Canada
关键词
electron beam; treatment planning; inhomogeneous phantom;
D O I
10.1118/1.598795
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We evaluated a commercial three-dimensional (3D) electron beam treatment planning system (CADPLAN V.2.7.9) using both experimentally measured and Monte Carlo calculated dose distributions to compare with those predicted by CADPLAN calculations. Tests were carried out at various field sizes and electron beam energies from 6 to 20 MeV. For a homogeneous water phantom the agreement between measured and CADPLAN calculated dose distributions is very good except at the phantom surface. CADPLAN is able to predict hot and cold spots caused by a simple 3D inhomogeneity but unable to predict dose distributions for a more complex geometry where CADPLAN underestimates dose changes caused by inhomogeneity. We discussed possible causes for the inaccuracy in the CADPLAN dose calculations. In addition, we have tested CADPLAN treatment monitor unit and electron cut-out factor calculations and found that CADPLAN predictions generally agree with manual calculations. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00412-5].
引用
收藏
页码:2571 / 2580
页数:10
相关论文
共 50 条
  • [41] Ion beam polishing for three-dimensional electron backscattered diffraction
    Saowadee, N.
    Agersted, K.
    Ubhi, H. S.
    Bowen, J. R.
    JOURNAL OF MICROSCOPY, 2013, 249 (01) : 36 - 40
  • [42] Solutions to Equations of a Three-Dimensional Electron Beam in Elementary Functions
    V. A. Syrovoi
    Journal of Communications Technology and Electronics, 2019, 64 : 1437 - 1444
  • [43] Three-Dimensional Thermal Calculation of Electron Beam Welding.
    Chastanet, B.
    Gascoin, J.Y.
    Rongier, P.
    Revue Generale de Thermique, 1979, 18 (208): : 205 - 213
  • [44] Three-Dimensional Control of the Doses by Scanning Method of Electron Beam
    Sugihara T.
    Kaneko A.
    IEEJ Transactions on Sensors and Micromachines, 2023, 143 (02) : 26 - 31
  • [45] Image quality of three-dimensional electron beam coronary angiography
    Lu, B
    Zhuang, N
    Mao, SS
    Bakhsheshi, H
    Liu, SCK
    Budoff, MJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (02) : 202 - 209
  • [46] Solutions to Equations of a Three-Dimensional Electron Beam in Elementary Functions
    Syrovoi, V. A.
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2019, 64 (12) : 1437 - 1444
  • [47] Model Three-Dimensional Relativistic Electron Beam in Crossed Fields
    Kovtun, D. G.
    Kravchina, P. D.
    Shamov, E. A.
    Shein, A. G.
    2014 TENTH INTERNATIONAL VACUUM ELECTRON SOURCES CONFERENCE (IVESC), 2014,
  • [48] Beam and MLC Commissioning and Assessment of Three Commercial Treatment Planning Systems
    Lim, S.
    LoSasso, T.
    MEDICAL PHYSICS, 2012, 39 (06) : 3828 - 3828
  • [49] Evaluation of the dry resist octavinylsilsesquioxan and its application to three-dimensional electron-beam lithography
    Koops, HWP
    Babin, S
    Weber, M
    Dahm, G
    Holopkin, A
    Lyakhov, M
    ADVANCES IN RESIST TECHNOLOGY AND PROCESSING XIII, 1996, 2724 : 578 - 587
  • [50] A retrospective study of external beam treatment for carcinoma of the breast combining CT scanning and three-dimensional treatment planning
    Dawes, PJDK
    Wilkinson, J
    Wilsdon, JB
    QUANTITATIVE IMAGING IN ONCOLOGY: 19TH L H GRAY CONFERENCE, 1996, : 94 - 95