Clutter filters adapted to tissue motion in ultrasound color flow imaging

被引:110
作者
Bjærum, S [1 ]
Torp, H
Kristoffersen, K
机构
[1] GE Co, Vingmed Ultrasound, Horten, Norway
[2] Norwegian Univ Sci & Technol, Dept Physiol & Biomed Engn, N-7034 Trondheim, Norway
关键词
D O I
10.1109/TUFFC.2002.1009328
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The quality of ultrasound color flow images is highly dependent on sufficient attenuation of the clutter signals originating from stationary and slowly moving tissue. Without sufficient clutter rejection, the detection of low velocity blood flow will be poor, and the velocity estimates will have a large bias. In some situations, e.g., when imaging the coronary arteries or when the operator moves the probe in search for small vessels, there is considerable movement of tissue. It has been suggested that clutter rejection can be improved by mixing down the signal with an estimate of the mean frequency prior to high pass filtering. In this paper, we compare this algorithm with several other adaptive clutter filtering algorithms using both experimental data and simulations. We found that realistic accelerations of the tissue have a large effect on the clutter rejection. The best results were obtained by mixing down the signal with non-constant phase increments estimated from the signal. This adapted the filter to a possibly accelerated tissue motion and produced a significant improvement in clutter rejection.
引用
收藏
页码:693 / 704
页数:12
相关论文
共 12 条
  • [1] [Anonymous], 1998, FUNDEMENTALS STAT SI
  • [2] [Anonymous], 1992, DISCRETE RANDOM SIGN
  • [3] BJAERUM S, 1997, P IEEE ULTR S, V2, P1223
  • [4] AN EFFICIENT ALGORITHM TO REMOVE LOW-FREQUENCY DOPPLER SIGNALS IN DIGITAL DOPPLER SYSTEMS
    HOEKS, APG
    VANDEVORST, JJW
    DABEKAUSSEN, A
    BRANDS, PJ
    RENEMAN, RS
    [J]. ULTRASONIC IMAGING, 1991, 13 (02) : 135 - 144
  • [5] Jensen J. A., 1996, Estimation of Blood Velocities using Ultrasound-A Signal Processing Approach
  • [6] JENSEN JA, FIELD 2 PROGRAM SIMU
  • [7] ON THE PERFORMANCE OF REGRESSION AND STEP-INITIALIZED IIR CLUTTER FILTERS FOR COLOR DOPPLER SYSTEMS IN DIAGNOSTIC MEDICAL ULTRASOUND
    KADI, AP
    LOUPAS, T
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (05) : 927 - 937
  • [8] REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE
    KASAI, C
    NAMEKAWA, K
    KOYANO, A
    OMOTO, R
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03): : 458 - 464
  • [9] Ledoux LAF, 1997, ULTRASONIC IMAGING, V19, P1
  • [10] Papoulis A., 1991, PROBABILITY RANDOM V