Detection of thyroid remnant/metastasis without stunning: An ongoing dilemma

被引:89
作者
Park, HM
Park, YH
Zhou, XH
机构
[1] INDIANA UNIV HOSP,DEPT RADIOL,INDIANAPOLIS,IN 46202
[2] INDIANA UNIV HOSP,SCH MED,DEPT BIOSTAT,INDIANAPOLIS,IN 46202
关键词
D O I
10.1089/thy.1997.7.277
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of I-131 in doses of several mCi for scans can stun the thyrocytes and thyroid cancer cells, whereas the usual dose (300 mu Ci) of I-123 does not. We compared the diagnostic accuracy of the I-123 (300 mu Ci) scans and that of I-131 (3-10 mCi) scans in 155 patients. The diagnostic accuracy of a I-123 scan in detecting functioning thyroid remnant/metastasis was 89.5% (77/86 scans) and that of a I-131 scan was 92.9% (39/42) in 6 week-postoperative patients (p = 0.750). For radioablation therapy follow-up patients, the diagnostic accuracy of I-123 in determining presence or absence of functioning remnant or metastasis was 69.4% (25/36) and that of I-131 was 92.5% (49/53) with a p value of 0.079. The success rates for complete ablation of functioning tissue after radioiodine therapy administered after diagnostic I-123 and after I-131 were 72% (34/47) and 56% (24/43), respectively, with a p value of 0.125. Our study indicates the following: 1) for the first postoperative evaluation, the diagnostic accuracy of the I-123 scan was essentially equal to that of the I-131 scan, and the success rate of radioablation therapy appears to be better after an I-123 scan; and 2) for postablation follow-up surveys, the I-131 scan appears to be better but carries the risk of stunning the functioning cells.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 13 条
  • [1] Becker D, 1996, J NUCL MED, V37, P1264
  • [2] COAKLEY AJ, 1980, J NUCL MED, V21, P803
  • [3] INFLUENCE OF INITIAL LARGE DOSE ON SUBSEQUENT UPTAKE OF THERAPEUTIC RADIOIODINE IN THYROID-CANCER PATIENTS
    JEEVANRAM, RK
    SHAH, DH
    SHARMA, SM
    GANATRA, RD
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 1986, 13 (03): : 277 - 279
  • [4] KIM CK, 1994, J NUCL MED, V35, pP14
  • [5] MAXON HR, 1993, J NUCL MED, V34, pP42
  • [6] NEMEC J, 1979, J NUCL MED, V20, P92
  • [7] RADIONUCLIDES AND THERAPY OF THYROID-CANCER
    ODOHERTY, MJ
    NUNAN, TO
    CROFT, DN
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1993, 14 (09) : 736 - 755
  • [8] STUNNED THYROID AFTER HIGH-DOSE I-131 IMAGING
    PARK, HM
    [J]. CLINICAL NUCLEAR MEDICINE, 1992, 17 (06) : 501 - 502
  • [9] INFLUENCE OF DIAGNOSTIC RADIOIODINES ON THE UPTAKE OF ABLATIVE DOSE OF I-131
    PARK, HM
    PERKINS, OW
    EDMONDSON, JW
    SCHNUTE, RB
    MANATUNGA, A
    [J]. THYROID, 1994, 4 (01) : 49 - 54
  • [10] PARK HM, 1992, RADIOL DIAGN, V33, P168