Automated detection of breast cancer in false-negative screening MRI studies from women at increased risk

被引:22
作者
Gubern-Merida, Albert [1 ,2 ]
Vreemann, Suzan [1 ]
Marti, Robert [2 ]
Melendez, Jaime [1 ]
Lardenoije, Susanne [1 ]
Mann, Ritse M. [1 ]
Karssemeijer, Nico [1 ]
Platel, Bram [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Radiol & Nucl Med, NL-6525 GA Nijmegen, Netherlands
[2] Univ Girona, Dept Comp Architecture & Technol, Girona 17071, Spain
关键词
Breast cancer; Magnetic resonance imaging; Screening; Computer aided detection; COMPUTER-AIDED DETECTION; MUTATION CARRIERS; MAMMOGRAPHY; MASSES; GUIDELINES; CARCINOMA; BRCA1;
D O I
10.1016/j.ejrad.2015.11.031
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of an automated computer-aided detection (CAD) system to detect breast cancers that were overlooked or misinterpreted in a breast MRI screening program for women at increased risk. Methods: We identified 40 patients that were diagnosed with breast cancer in MRI and had a prior MRI examination reported as negative available. In these prior examinations, 24 lesions could retrospectively be identified by two breast radiologists in consensus: 11 were scored as visible and 13 as minimally visible. Additionally, 120 normal scans were collected from 120 women without history of breast cancer or breast surgery participating in the same MRI screening program. A fully automated CAD system was applied to this dataset to detect malignant lesions. Results: At 4 false-positives per normal case, the sensitivity for the detection of cancer lesions that were visible or minimally visible in retrospect in prior-negative examinations was 0.71 (95% CI = 0.38-1.00) and 0.31 (0.07-0.59), respectively. Conclusions: A substantial proportion of cancers that were misinterpreted or overlooked in an MRI screening program was detected by a CAD system in prior-negative examinations. It has to be clarified with further studies if such a CAD system has an influence on the number of misinterpreted and overlooked cancers in clinical practice when results are given to a radiologist. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:472 / 479
页数:8
相关论文
共 27 条
[1]   A comparison of cancer detection rates achieved by breast cancer screening programmes by number of readers, for one and two view mammography: results from the UK National Health Service breast screening programme [J].
Blanks, RG ;
Wallis, MG ;
Moss, SM .
JOURNAL OF MEDICAL SCREENING, 1998, 5 (04) :195-201
[2]  
Burhenne LJW, 2000, RADIOLOGY, V215, P554
[3]   Computerized breast lesions detection using kinetic and morphologic analysis for dynamic contrast-enhanced MRI [J].
Chang, Yeun-Chung ;
Huang, Yan-Hao ;
Huang, Chiun-Sheng ;
Chen, Jeon-Hor ;
Chang, Ruey-Feng .
MAGNETIC RESONANCE IMAGING, 2014, 32 (05) :514-522
[4]   1977 RIETZ LECTURE - BOOTSTRAP METHODS - ANOTHER LOOK AT THE JACKKNIFE [J].
EFRON, B .
ANNALS OF STATISTICS, 1979, 7 (01) :1-26
[5]   Automated localization of breast cancer in DCE-MRI [J].
Gubern-Merida, Albert ;
Marti, Robert ;
Melendez, Jaime ;
Hauth, Jakob L. ;
Mann, Ritse M. ;
Karssemeijer, Nico ;
Platel, Bram .
MEDICAL IMAGE ANALYSIS, 2015, 20 (01) :265-274
[6]   PREVIOUS MAMMOGRAMS IN PATIENTS WITH IMPALPABLE BREAST-CARCINOMA - RETROSPECTIVE VS BLINDED INTERPRETATION [J].
HARVEY, JA ;
FAJARDO, LL ;
INNIS, CA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (06) :1167-1172
[7]   Computer-aided Detection of Masses at Mammography: Interactive Decision Support versus Prompts [J].
Hupse, Rianne ;
Samulski, Maurice ;
Lobbes, Marc B. ;
Mann, Ritse M. ;
Mus, Roel ;
den Heeten, Gerard J. ;
Beijerinck, David ;
Pijnappel, Ruud M. ;
Boetes, Carla ;
Karssemeijer, Nico .
RADIOLOGY, 2013, 266 (01) :123-129
[8]   Automatic detection of subsolid pulmonary nodules in thoracic computed tomography images [J].
Jacobs, Colin ;
van Rikxoort, Eva M. ;
Twellmann, Thorsten ;
Scholten, Ernst Th. ;
de Jong, Pim A. ;
Kuhnigk, Jan-Martin ;
Oudkerk, Matthijs ;
de Koning, Harry J. ;
Prokop, Mathias ;
Schaefer-Prokop, Cornelia ;
van Ginneken, Bram .
MEDICAL IMAGE ANALYSIS, 2014, 18 (02) :374-384
[9]   Computer-aided detection versus independent double reading of masses on mammograms [J].
Karssemeijer, N ;
Otten, JDM ;
Verbeek, ALM ;
Groenewoud, JH ;
de Koning, HJ ;
Hendriks, JHCL ;
Holland, R .
RADIOLOGY, 2003, 227 (01) :192-200
[10]   Efficacy of MRI and mammography for breast-cancer screening in women with a familial or genetic predisposition [J].
Kriege, M ;
Brekelmans, CTM ;
Boetes, C ;
Besnard, PE ;
Zonderland, HM ;
Obdeijn, IM ;
Manoliu, RA ;
Kok, T ;
Peterse, H ;
Tilanus-Linthorst, MMA ;
Muller, SH ;
Meijer, S ;
Oosterwijk, JC ;
Beex, LVAM ;
Tollenaar, RAEM ;
de Koning, HJ ;
Rutgers, EJT ;
Klijn, JGM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (05) :427-437