Non-invasive platform to estimate fasting blood glucose levels from salivary electrochemical parameters

被引:10
作者
Malik, Sarul [1 ]
Parikh, Harsh [2 ]
Shah, Neil [2 ]
Anand, Sneh [1 ,3 ]
Gupta, Shalini [4 ]
机构
[1] Indian Inst Technol Delhi, Ctr Biomed Engn, Delhi, India
[2] Indian Inst Technol Delhi, Dept Comp Sci, Delhi, India
[3] All India Inst Med Sci, Dept Biomed Engn, New Delhi 110016, India
[4] Indian Inst Technol Delhi, Dept Chem Engn, Delhi 110016, India
关键词
electrochemical sensors; graphical user interfaces; blood; diseases; sugar; calcium; patient diagnosis; potassium; sodium; pH measurement; medical computing; electrochemical properties; FBGL determination process; painless FBGL estimation; noninvasive platform; fasting blood glucose levels; salivary electrochemical parameters; metabolic disorder; proxy biofluid; portable sensors; ionic concentrations; diabetes; K+; Na+; Ca2+; DIABETES-MELLITUS; GLYCEMIC CONTROL; SENSORS; INFORMATICS; PROJECTIONS; POTASSIUM; CALCIUM; HEALTH;
D O I
10.1049/htl.2018.5081
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diabetes is a metabolic disorder that affects more than 400 million people worldwide. Most existing approaches for measuring fasting blood glucose levels (FBGLs) are invasive. This work presents a proof-of-concept study in which saliva is used as a proxy biofluid to estimate FBGL. Saliva collected from 175 volunteers was analysed using portable, handheld sensors to measure its electrochemical properties such as conductivity, redox potential, pH and K+, Na+ and Ca2+ ionic concentrations. These data, along with the person's gender and age, were trained and tested after casewise annotation with their true FBGL values using a set of mathematical algorithms. An accuracy of 87.4 +/- 1.7% and a mean relative deviation of 14.1% (R-2 = 0.76) was achieved using a mathematical algorithm. All parameters except the gender were found to play a key role in the FBGL determination process. Finally, the individual electrochemical sensors were integrated into a single platform and interfaced with the authors' algorithm through a simple graphical user interface. The system was revalidated on 60 new saliva samples and gave an accuracy of 81.67 +/- 2.53% (R-2 = 0.71). This study paves the way for rapid, efficient and painless FBGL estimation from saliva.
引用
收藏
页码:87 / 91
页数:5
相关论文
共 36 条
[1]   Evaluation of the state-of-the-art in informatics in glucometers [J].
Ajai, Oluseun ;
Tiwari, Ashutosh ;
Alcock, Jeffrey R. .
INFORMATICS FOR HEALTH & SOCIAL CARE, 2009, 34 (03) :171-179
[2]  
Amer Diabet Assoc, 2011, DIABETES CARE, V34, pS11, DOI [10.2337/dc11-S011, 10.2337/dc13-S067, 10.2337/dc10-S011, 10.2337/dc13-S011, 10.2337/dc11-S062, 10.2337/dc14-S081, 10.2337/dc12-s011, 10.2337/dc10-S062, 10.2337/dc12-s064]
[3]  
Amer S, 2001, Pak J Pharm Sci, V14, P33
[4]  
Amos AF, 1997, DIABETIC MED, V14, pS7, DOI 10.1002/(SICI)1096-9136(199712)14:5+<S7::AID-DIA522>3.3.CO
[5]  
2-I
[6]  
[Anonymous], STOMATOLOSKI GLASNIK
[7]   Noninvasive glucose sensing [J].
Arnold, MA ;
Small, GW .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5429-5439
[8]   A generalized feedforward neural network architecture for classification and regression [J].
Arulampalam, G ;
Bouzerdoum, A .
NEURAL NETWORKS, 2003, 16 (5-6) :561-568
[9]   Salivary alpha-amylase as a measure of endogenous adrenergic activity [J].
Chatterton, RT ;
Vogelsong, KM ;
Lu, YC ;
Ellman, AB ;
Hudgens, GA .
CLINICAL PHYSIOLOGY, 1996, 16 (04) :433-448
[10]   Health benefits of saliva: a review [J].
Dodds, MWJ ;
Johnson, DA ;
Yeh, CK .
JOURNAL OF DENTISTRY, 2005, 33 (03) :223-233