共 2 条
Hydraulic behavior of fault zones in pump tests of geothermal wells: a parametric analysis using numerical simulations for the Upper Jurassic aquifer of the North Alpine Foreland Basin
被引:15
|作者:
Konrad, Florian
[1
]
Savvatis, Alexandros
[2
]
Wellmann, Florian
[3
]
Zosseder, Kai
[1
]
机构:
[1] Tech Univ Munich, Arcisstr 21, D-80333 Munich, Germany
[2] Erdwerk GmbH, Bonner Pl 1, D-80803 Munich, Germany
[3] Rhein Westfal TH Aachen, Schinkelstr 2, D-52062 Aachen, Germany
关键词:
Numerical simulation;
Geothermal energy;
Well test analysis;
Parametric study;
Fault zone;
Malm;
Molasse Basin;
MOLASSE BASIN;
EVOLUTION;
PERMEABILITY;
ARCHITECTURE;
RESERVOIR;
GERMANY;
D O I:
10.1186/s40517-019-0137-4
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
Fault zones in the Upper Jurassic aquifer of the North Alpine Foreland Basin are generally regions with possibly increased hydraulic properties. They are consequently often part of the geothermal exploration concepts in this area and a primary target for the drilling operation. Data from this aquifer, gathered in pump tests, however, show that only four out of 41 successful wells exhibit hydraulic proof for the presence of such a fault zone in terms of a bi-/linear flow regime. Besides technical effects, also the contrast in hydraulic properties itself, between fault zone and surrounding host rock, can prevent the detection of a fault zone in pump test data. This means a certain threshold has to be surpassed until its effects become clearly visible. A simplified realistic numerical model was constructed and calibrated with pressure data from an exploration site in the south of Munich. This model was then used to observe the presence of linear and bilinear flows in dependence on the Malm aquifers parameter space. Sampling the possible hydraulic property combinations with the help of an HPC (high-performance computing) cluster and automating the detection of the corresponding main flow type allowed to quantify the areas in parameter space where the fault zone-related flow regimes of interest are present. Through the investigation of more than 30,000 combinations between fault zone permeability, matrix permeability, fault zone storage, matrix storage and fault zone thickness, it was found that, in the parameter space of the Malm aquifer, a bilinear flow can be observed for the first time only if the matrix permeability is lower than 2.0 x 10(-13) m(2), and a linear flow for matrix permeability values below 6.0 x 10(-14) m(2). Additionally, it was shown that fault zones, which have better hydraulic properties than the surrounding matrix, can indeed be hidden in pumping tests due to the parameter setting.