High Signal Intensity in Globus Pallidus and Dentate Nucleus on Unenhanced T1-weighted MR Images: Evaluation of Two Linear Gadolinium-based Contrast Agents

被引:193
作者
Ramalho, Joana [1 ]
Castillo, Mauricio [1 ]
AlObaidy, Mamdoh [1 ,2 ]
Nunes, Renato H. [1 ]
Ramalho, Miguel [1 ]
Dale, Brian M. [3 ]
Semelka, Richard C. [1 ]
机构
[1] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[2] King Faisal Specialist Hosp & Res Ctr, Dept Radiol, Riyadh 11211, Saudi Arabia
[3] Siemens Healthcare, Cary, NC USA
关键词
NEPHROGENIC SYSTEMIC FIBROSIS; BIODISTRIBUTION; GADOTERIDOL; GADODIAMIDE;
D O I
10.1148/radiol.2015150872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine if a correlation exists between the number of previous enhanced magnetic resonance (MR) imaging examinations and high signal intensity in the globus pallidus (GP) and dentate nucleus (DN) in patients who received gadodiamide (Omniscan), a linear nonionic gadolinium-based contrast agent, and in those who received gadobenate dimeglumine (MultiHance), a linear ionic contrast agent. Materials and Methods: Institutional review board approval was obtained for this single-center retrospective study, with waiver of informed consent. The study population included 69 patients divided into two groups: Group 1 included patients who underwent gadodiamide-enhanced MR imaging, and group 2 included patients who underwent gadobenate dimeglumine-enhanced MR imaging. Two radiologists conducted a quantitative analysis of unenhanced T1-weighted images by using region of interest measurements. The GP-to-thalamus (TH) signal intensity ratio, DN-to-middle cerebellar peduncle (MCP) signal intensity ratio and relative percentage change (R change) between the first and last examinations for each patient were calculated. Relation between the signal intensity ratios and R change and the number of enhanced MR imaging examinations was analyzed by using a generalized additive model. Inter-and intraobserver agreement was evaluated with the Lin concordance correlation coefficient test. Results: Group 1 included 23 patients (19 female), with a mean of 5.0 doses 6 2.4 (standard deviation) (range, 3-11 doses) administered. Group 2 included 46 patients (24 female) with a mean of 4.6 doses 6 2.2 (range, 3-11 doses) administered. The interval between the first and last examination was 1500.1 days +/- 780.2 (range, 98-3097 days) for group 1 and 1086.2 days +/- 582.9 (range, 942633) for group 2. All patients had normal liver and renal function. Gadodiamide showed a significant increase in DN: MCP and GP: TH (P < .001 for both) and in R-change (P = .001 for GP: TH, P < .001 for DN: MCP). In group 2, there was no significant increase in DN: MCP or GP: TH over time or in R-change for GP: TH, but there was a significant trend toward an increase in R-change for DN: MCP (P = .013). Interobserver agreement was almost perfect (0.99; 95% confidence interval: 0.99, 0.99) for all evaluated structures. Intraobserver agreement was substantial to almost perfect for both readers. Conclusion: A significant increase in GP: TH and DN: MCP is associated with multiple gadodiamide-enhanced studies but not with gadobenate dimeglumine-enhanced studies, likely reflecting differences in stability and elimination of both contrast agents. Rate-of-change data indirectly suggest gadolinium deposition in the DN with gadobenate dimeglumine use, although it is considerably less than that with gadodiamide use. (C) RSNA, 2015
引用
收藏
页码:836 / 844
页数:9
相关论文
共 26 条
  • [1] Nephrogenic Systemic Fibrosis and Management of High-risk Patients
    Altun, Ersan
    Semelka, Richard C.
    Cakit, Ceylan
    [J]. ACADEMIC RADIOLOGY, 2009, 16 (07) : 897 - 905
  • [2] [Anonymous], INVEST RADIOL
  • [3] [Anonymous], ACAD RADIOL S1
  • [4] Diagnosis of Nephrogenic Systemic Fibrosis by means of Elemental Bioimaging and Speciation Analysis
    Birka, Marvin
    Wentker, Kristina S.
    Lusmoeller, Elke
    Arheilger, Brigit
    Wehe, Christoph A.
    Sperling, Michael
    Stadler, Rudolf
    Karst, Uwe
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (06) : 3321 - 3328
  • [5] de Campos ROP, 2010, CHEM ENG METHOD TECH, P217
  • [6] Progressive Increase of T1 Signal Intensity of the Dentate Nucleus on Unenhanced Magnetic Resonance Images Is Associated With Cumulative Doses of Intravenously Administered Gadodiamide in Patients With Normal Renal Function, Suggesting Dechelation
    Errante, Yuri
    Cirimele, Vincenzo
    Mallio, Carlo Augusto
    Di Lazzaro, Vincenzo
    Zobel, Bruno Beomonte
    Quattrocchi, Carlo Cosimo
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 685 - 690
  • [7] Biochemical safety profiles of gadolinium-based extracellular contrast agents and nephrogenic systemic fibrosis
    Ersoy, Hale
    Rybicki, Frank J.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) : 1190 - 1197
  • [8] Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C
    Frenzel, Thomas
    Lengsfeld, Philipp
    Schirmer, Heiko
    Huetter, Joachim
    Weinmann, Hanns-Joachim
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (12) : 817 - 828
  • [9] Hastie T., 1990, Generalized Additive Models, DOI [10.1201/9780203753781, DOI 10.1002/9781118445112.STAT03141]
  • [10] MR Imaging in Patients at Risk for Developing Nephrogenic Systemic Fibrosis: Protocols, Practices, and Imaging Techniques to Maximize Patient Safety
    Juluru, Krishna
    Vogel-Claussen, Jens
    Macura, Katarzyna J.
    Kamel, Ihab R.
    Steever, Alexander
    Bluemke, David A.
    [J]. RADIOGRAPHICS, 2009, 29 (01) : 9 - 22