Copper corrosion in mildly alkaline water with the disinfectant monochloramine

被引:110
作者
Zhang, XH
Pehkonen, SO
Kocherginsky, N
Ellis, GA
机构
[1] Natl Univ Singapore, Dept Environm Chem & Engn, Singapore 119260, Singapore
[2] Natl Univ Singapore, Dept Elect & Comp Engn, Singapore 119260, Singapore
关键词
copper; corrosion; monochloramine; electrochemical impedance spectroscopy (EIS); polarization resistance (R-p);
D O I
10.1016/S0010-938X(02)00021-5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The corrosion of pure copper for a period of 2-30 days was investigated in simulated tap water containing monochloramine (normally at 4.0 mg/l) in the pH range of 7.6-8.4, using electrochemical impedance spectroscopy, potentiodynamic scan, X-ray photoelectron spectroscopy (XPS), inductively coupled plasma and scanning electronic microscopy (SEM). The XPS spectra and SEM indicated that after 8 days of immersion, the copper surface was covered by both cupric and cuprous oxides. Diffusion in the oxide film was found having a significant effect on the corrosion process. The results showed that at pH 8.0 the polarization resistance (R-P) increased with time during the first 6 days and reached relative stability after 8 days. An equivalent circuit model was proposed to fit the corrosion process, and the elements extracted from the model predicted a corrosion rate in the order of 0.1 mum/yr at pH of 8.0. The values of R-P increased with higher pH for all 2, 4, 6, and 8-day immersions, but decreased at a higher monochloramine concentration of 20 mg/l. In the control experiment, R-P had the largest value after a 30-day immersion time. Dissolved inorganic carbon (DIC) enhancess the dissolution of copper by a factor of 2, when the concentration of DIC increased from 0.59 to 4.0 mM. Increasing ionic strength from 0.005 to 0.02 M reduced R-P, but the increase of R-P with immersion time was faster at higher ionic strengths. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2507 / 2528
页数:22
相关论文
共 38 条
[1]  
BARRETT SG, 1952, J I WATER ENG, V6, P145
[2]   A NONLINEAR LEAST-SQUARES FIT PROCEDURE FOR ANALYSIS OF IMMITTANCE DATA OF ELECTROCHEMICAL SYSTEMS [J].
BOUKAMP, BA .
SOLID STATE IONICS, 1986, 20 (01) :31-44
[3]   A PACKAGE FOR IMPEDANCE ADMITTANCE DATA-ANALYSIS [J].
BOUKAMP, BA .
SOLID STATE IONICS, 1986, 18-9 (pt 1) :136-140
[4]   Role of temperature, chlorine, and organic matter in copper corrosion by-product release in soft water [J].
Boulay, N ;
Edwards, M .
WATER RESEARCH, 2001, 35 (03) :683-690
[5]   Copper corrosion in drinking water distribution systems - The influence of water quality [J].
Broo, AE ;
Berghult, B ;
Hedberg, T .
CORROSION SCIENCE, 1997, 39 (06) :1119-1132
[6]   An XPS and BAW sensor study of the structure and real-time growth behaviour of a complex surface film on copper in sodium chloride solutions (pH=9), containing a low concentration of benzotriazole [J].
Chen, JH ;
Lin, ZC ;
Chen, S ;
Nie, LH ;
Yao, SZ .
ELECTROCHIMICA ACTA, 1998, 43 (3-4) :265-274
[7]  
COTTON FA, 1988, ADV INORG CHEM RAD, P758
[8]  
DAISTRICK ID, 1987, IMPEDANCE SPECTROSCO, P27
[9]  
EDWARDS M, 1994, J AM WATER WORKS ASS, V86, P73
[10]  
Edwards M, 1996, J AM WATER WORKS ASS, V88, P81