A Comparison of Dual Gradient-Echo and Spin-Echo fMRI of the Inferior Temporal Lobe

被引:89
|
作者
Halai, Ajay D. [1 ]
RWelbourne, Stephen [1 ]
Embleton, Karl [2 ]
Parkes, Laura M. [3 ]
机构
[1] Univ Manchester, Sch Psychol Sci, Neurosci & Aphasia Res Unit, Manchester M13 9PL, Lancs, England
[2] Univ Manchester, Sch Psychol Sci, Cognit & Cognit Neurosci Grp, Manchester M13 9PL, Lancs, England
[3] Univ Manchester, Inst Populat Hlth, Ctr Imaging Sci, Manchester M13 9PL, Lancs, England
关键词
dual echo; spin echo; EPI; magnetic susceptibility; inferior temporal lobe; BOLD-CONTRAST SENSITIVITY; INDUCED SIGNAL LOSSES; SEMANTIC DEMENTIA; OPTIMIZED EPI; PLANAR FMRI; SUSCEPTIBILITY; REDUCTION; COMPENSATION; CORTEX; REPRESENTATION;
D O I
10.1002/hbm.22463
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Magnetic susceptibility differences at tissue interfaces lead to signal loss in conventional gradient-echo (GE) EPI. This poses a problem for fMRI in language and memory paradigms, which activate the most affected regions. Two methods proposed to overcome this are spin-echo EPI and dual GE EPI, where two EPI read-outs are serially collected at a short and longer echo time. The spinecho method applies a refocusing pulse to recover dephased MR signal due to static field inhomogeneities, but is known to have a relatively low blood oxygenation level dependant (BOLD) sensitivity. In comparison, GE has superior BOLD sensitivity, and by employing an additional shorter echo, in a dual GE sequence, it can reduce signal loss due to spin dephasing. We directly compared dual GE and spin-echo fMRI during a semantic categorization task, which has been shown to activate the inferior temporal region-a region known to be affected by magnetic susceptibility. A whole brain analysis showed that the dual GE resulted in significantly higher activation within the left inferior temporal fusiform (ITF) cortex, compared to spin-echo. The inferior frontal gyrus (IFG) was activated for dual GE, but not spin-echo. Regions of interest analysis was carried out on the anterior and posterior ITF, left and right IFG, and part of the cerebellum. Dual GE outperformed spin-echo in the anterior and posterior ITF and bilateral IFG regions, whilst being equal in the cerebellum. Hence, dual GE should be the method of choice for fMRI studies of inferior temporal regions. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:4118 / 4128
页数:11
相关论文
共 50 条
  • [21] INTRACRANIAL GRADIENT-ECHO AND SPIN-ECHO FUNCTIONAL MR-ANGIOGRAPHY IN HUMANS
    BELLE, V
    DELONMARTIN, C
    MASSARELLI, R
    DECETY, J
    LEBAS, JF
    BENABID, AL
    SEGEBARTH, C
    RADIOLOGY, 1995, 195 (03) : 739 - 746
  • [22] Focal nodular hyperplasia of the liver on ferumoxides-enhanced MR imaging: Comparison of conventional spin-echo, fast spin-echo and gradient-echo images
    Precetti, S
    Bellin, M
    Ghebontni, L
    Zaim, S
    Cluzel, P
    Grenier, PA
    RADIOLOGY, 1997, 205 : 1330 - 1330
  • [23] Anomalies of pulmonary veins: Usefulness of spin-echo and gradient-echo MR images
    White, CS
    Baffa, JM
    Haney, PJ
    Campbell, AB
    NessAiver, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) : 1365 - 1368
  • [24] CARDIAC MASSES - SIGNAL INTENSITY FEATURES ON SPIN-ECHO, GRADIENT-ECHO, GADOLINIUM-ENHANCED SPIN-ECHO, AND TURBOFLASH IMAGES
    SEMELKA, RC
    SHOENUT, JP
    WILSON, ME
    PELLECH, AE
    PATTON, JN
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04): : 415 - 420
  • [25] Spin-echo and 3D gradient-echo imaging of the knee joint: A clinical and histopathological comparison
    Guckel, C
    Jundt, G
    Schnabel, K
    Gachter, A
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 21 (01) : 25 - 33
  • [26] MR imaging of hemorrhagic brain lesions: A comparison of dual-echo gradient- and spin-echo and fast spin-echo techniques
    Melhem, ER
    Patel, RT
    Whitehead, RE
    Bhatia, RG
    Rockwell, DT
    Jara, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) : 797 - 802
  • [27] A COMPARISON OF FAST SPIN-ECHO AND GRADIENT FIELD ECHO SEQUENCES
    TKACH, JA
    HAACKE, EM
    MAGNETIC RESONANCE IMAGING, 1988, 6 (04) : 373 - 389
  • [28] Liver Iron Content Determined by MRI: Spin-Echo vs. Gradient-Echo
    Juchems, M. S.
    Cario, H.
    Schmid, M.
    Wunderlich, A. P.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (05): : 427 - 431
  • [30] POSTSTENOTIC FLOW IN MRI - INVITRO INVESTIGATION USING SPIN-ECHO AND GRADIENT-ECHO SEQUENCES
    SPIELMANN, RP
    THIELE, F
    HELLER, M
    BUCHELER, E
    DIGITALE BILDDIAGNOSTIK, 1989, 9 (02): : 55 - 58