CPAP Pressure for Prediction of Oral Appliance Treatment Response in Obstructive Sleep Apnea

被引:46
作者
Sutherland, Kate [1 ,2 ]
Phillips, Craig L. [1 ,2 ]
Davies, Amanda [1 ,2 ]
Srinivasan, Vasanth K. [3 ]
Dalci, Oyku [3 ]
Yee, Brendon J. [1 ,4 ]
Darendeliler, M. Ali [3 ]
Grunstein, Ronald R. [1 ,4 ]
Cistulli, Peter A. [1 ,2 ]
机构
[1] Univ Sydney, NHMRC Ctr Sleep Hlth CIRUS, Sydney, NSW 2006, Australia
[2] Royal N Shore Hosp, Dept Resp Med, Ctr Sleep Hlth & Res, Sydney, NSW, Australia
[3] Univ Sydney, Sydney Dent Hosp, Fac Dent, Discipline Orthodont, Sydney, NSW 2006, Australia
[4] Royal Prince Alfred Hosp, Dept Resp & Sleep Med, Sydney, NSW, Australia
来源
JOURNAL OF CLINICAL SLEEP MEDICINE | 2014年 / 10卷 / 09期
关键词
obstructive sleep apnea; oral appliance; continuous positive airway pressure; treatment response; POSITIVE AIRWAY PRESSURE; MANDIBULAR ADVANCEMENT DEVICES; COMPUTATIONAL FLUID-DYNAMICS; CRANIOFACIAL STRUCTURE; THERAPY; EFFICACY; CHINESE; OBESITY; MEN;
D O I
10.5664/jcsm.4020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Mandibular advancement splints (MAS) are often preferred to CPAP treatment for OSA but are not always equally efficacious. High therapeutic CPAP pressure has been associated with MAS treatment failure in a Japanese population. We sought to assess the relationship between CPAP pressure and MAS treatment response in an Australian population. Methods: Therapeutic CPAP pressure and MAS treatment response were obtained from a one-month crossover trial of both treatments. Predictive utility of CPAP pressure to identify MAS treatment response was assessed. Results: Seventy-eight OSA patients were included (age 49.3 +/- 11.1 years, BMI 29.1 +/- 5.8 kg/m(2)) with predominantly moderate-severe OSA (AHI 30.0 +/- 12.7/h). CPAP pressure was lower in MAS responders (MAS AHI < 10/h) 9.7 +/- 1.6 vs. 11.7 +/- 2.4 cm H2O, p < 0.01, with area under ROC curve of 0.74 (95% CI 0.63-0.86), p < 0.01. The best cutoff value of 10.5 cm H2O useful for discriminating MAS responders and non-responders in the previous Japanese population, was inadequate for prediction in the current population (0.47 negative predictive value [NPV]). However a cutoff of 13 cm H2O identified MAS non-responders (1.0 NPV). Multivariate regression identified CPAP pressure (odds ratio [95% confidence interval] 0.53 [0.33-0.87], age (0.93 [0.87-0.99]) and AHI (0.92 [0.86-0.97]) as predictors of MAS treatment response (model r(2) = 0.54, p < 0.001). Conclusions: In Australian patients, the majority of whom are Caucasian, a higher therapeutic CPAP pressure requirement in conjunction with age and OSA severity characteristics may be useful to indicate likelihood of success with MAS as an alternative therapy.
引用
收藏
页码:943 / 949
页数:7
相关论文
共 50 条
[21]   Efficacy of an Oral Appliance for the Treatment of Obstructive Sleep Apnea [J].
Giannasi, Lilian Chrystiane ;
Almeida, Fernanda Ribeiro ;
Nacif, Sergio Roberto ;
Franco de Oliveira, Luis Vicente .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (04) :334-339
[22]   Treatment of obstructive sleep apnea with the Karwetzky oral appliance [J].
Rose, E ;
Staats, R ;
Schulte-Mönting, J ;
Jonas, IE .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2002, 110 (02) :99-105
[23]   A feasibility evaluation of oral pressure therapy for the treatment of obstructive sleep apnea [J].
Farid-Moayer, Mehran ;
Siegel, Lawrence C. ;
Black, Jed .
THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2012, 7 (01) :3-12
[24]   Oral appliance therapy for the management of obstructive sleep apnea in adults: an umbrella review protocol [J].
Ghosh, Parvathy ;
Janakiram, Chandrashekar ;
Kovilakam, Sapna Varma Nilambur ;
Velath, Ajith Vallikat ;
Kadekuzhi, Sarika .
JBI EVIDENCE SYNTHESIS, 2023, 21 (08) :1624-1631
[25]   Comparison of Adjustable and Fixed Oral Appliances for the Treatment of Obstructive Sleep Apnea [J].
Lettieri, Christopher J. ;
Paolino, Nathalie ;
Eliasson, Arn H. ;
Shah, Anita A. ;
Holley, Aaron B. .
JOURNAL OF CLINICAL SLEEP MEDICINE, 2011, 7 (05) :439-445
[26]   A 2-year mean follow-up of oral appliance therapy for severe obstructive sleep apnea: a cohort study [J].
Haviv, Y. ;
Bachar, G. ;
Aframian, D. J. ;
Almoznino, G. ;
Michaeli, E. ;
Benoliel, R. .
ORAL DISEASES, 2015, 21 (03) :386-392
[27]   Prediction of non-responders to oral appliance treatment of obstructive sleep apnea: a pilot study [J].
Opsahl, Ulrik Leidland ;
Berge, Morten ;
Lehmann, Sverre ;
Bjorvatn, Bjorn ;
Johansson, Anders .
SLEEP AND BREATHING, 2025, 29 (02)
[28]   Adjustable Thermoplastic Oral Appliance Versus Positive Airway Pressure for Obstructive Sleep Apnea [J].
Banhiran, Wish ;
Assanasen, Paraya ;
Nopmaneejumrudlers, Cherdchai ;
Nujchanart, Nongyoaw ;
Srechareon, Wimontip ;
Chongkolwatana, Cheerasook ;
Metheetrairut, Choakchai .
LARYNGOSCOPE, 2018, 128 (02) :516-522
[29]   The value of auto-adjustable CPAP devices in pressure titration and treatment of patients with obstructive sleep apnea syndrome [J].
Hertegonne, Katrien ;
Bauters, Fre .
SLEEP MEDICINE REVIEWS, 2010, 14 (02) :115-119
[30]   Does CPAP treatment in mild obstructive sleep apnea affect blood pressure? [J].
Jaimchariyatam, Nattapong ;
Rodriguez, Carlos L. ;
Budur, Kumar .
SLEEP MEDICINE, 2010, 11 (09) :837-842