CPAP Pressure for Prediction of Oral Appliance Treatment Response in Obstructive Sleep Apnea

被引:46
作者
Sutherland, Kate [1 ,2 ]
Phillips, Craig L. [1 ,2 ]
Davies, Amanda [1 ,2 ]
Srinivasan, Vasanth K. [3 ]
Dalci, Oyku [3 ]
Yee, Brendon J. [1 ,4 ]
Darendeliler, M. Ali [3 ]
Grunstein, Ronald R. [1 ,4 ]
Cistulli, Peter A. [1 ,2 ]
机构
[1] Univ Sydney, NHMRC Ctr Sleep Hlth CIRUS, Sydney, NSW 2006, Australia
[2] Royal N Shore Hosp, Dept Resp Med, Ctr Sleep Hlth & Res, Sydney, NSW, Australia
[3] Univ Sydney, Sydney Dent Hosp, Fac Dent, Discipline Orthodont, Sydney, NSW 2006, Australia
[4] Royal Prince Alfred Hosp, Dept Resp & Sleep Med, Sydney, NSW, Australia
来源
JOURNAL OF CLINICAL SLEEP MEDICINE | 2014年 / 10卷 / 09期
关键词
obstructive sleep apnea; oral appliance; continuous positive airway pressure; treatment response; POSITIVE AIRWAY PRESSURE; MANDIBULAR ADVANCEMENT DEVICES; COMPUTATIONAL FLUID-DYNAMICS; CRANIOFACIAL STRUCTURE; THERAPY; EFFICACY; CHINESE; OBESITY; MEN;
D O I
10.5664/jcsm.4020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Mandibular advancement splints (MAS) are often preferred to CPAP treatment for OSA but are not always equally efficacious. High therapeutic CPAP pressure has been associated with MAS treatment failure in a Japanese population. We sought to assess the relationship between CPAP pressure and MAS treatment response in an Australian population. Methods: Therapeutic CPAP pressure and MAS treatment response were obtained from a one-month crossover trial of both treatments. Predictive utility of CPAP pressure to identify MAS treatment response was assessed. Results: Seventy-eight OSA patients were included (age 49.3 +/- 11.1 years, BMI 29.1 +/- 5.8 kg/m(2)) with predominantly moderate-severe OSA (AHI 30.0 +/- 12.7/h). CPAP pressure was lower in MAS responders (MAS AHI < 10/h) 9.7 +/- 1.6 vs. 11.7 +/- 2.4 cm H2O, p < 0.01, with area under ROC curve of 0.74 (95% CI 0.63-0.86), p < 0.01. The best cutoff value of 10.5 cm H2O useful for discriminating MAS responders and non-responders in the previous Japanese population, was inadequate for prediction in the current population (0.47 negative predictive value [NPV]). However a cutoff of 13 cm H2O identified MAS non-responders (1.0 NPV). Multivariate regression identified CPAP pressure (odds ratio [95% confidence interval] 0.53 [0.33-0.87], age (0.93 [0.87-0.99]) and AHI (0.92 [0.86-0.97]) as predictors of MAS treatment response (model r(2) = 0.54, p < 0.001). Conclusions: In Australian patients, the majority of whom are Caucasian, a higher therapeutic CPAP pressure requirement in conjunction with age and OSA severity characteristics may be useful to indicate likelihood of success with MAS as an alternative therapy.
引用
收藏
页码:943 / 949
页数:7
相关论文
共 50 条
  • [21] Treatment of obstructive sleep apnea with the Karwetzky oral appliance
    Rose, E
    Staats, R
    Schulte-Mönting, J
    Jonas, IE
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2002, 110 (02) : 99 - 105
  • [22] A feasibility evaluation of oral pressure therapy for the treatment of obstructive sleep apnea
    Farid-Moayer, Mehran
    Siegel, Lawrence C.
    Black, Jed
    THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2012, 7 (01) : 3 - 12
  • [23] Oral appliance therapy for the management of obstructive sleep apnea in adults: an umbrella review protocol
    Ghosh, Parvathy
    Janakiram, Chandrashekar
    Kovilakam, Sapna Varma Nilambur
    Velath, Ajith Vallikat
    Kadekuzhi, Sarika
    JBI EVIDENCE SYNTHESIS, 2023, 21 (08) : 1624 - 1631
  • [24] Comparison of Adjustable and Fixed Oral Appliances for the Treatment of Obstructive Sleep Apnea
    Lettieri, Christopher J.
    Paolino, Nathalie
    Eliasson, Arn H.
    Shah, Anita A.
    Holley, Aaron B.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2011, 7 (05): : 439 - 445
  • [25] A 2-year mean follow-up of oral appliance therapy for severe obstructive sleep apnea: a cohort study
    Haviv, Y.
    Bachar, G.
    Aframian, D. J.
    Almoznino, G.
    Michaeli, E.
    Benoliel, R.
    ORAL DISEASES, 2015, 21 (03) : 386 - 392
  • [26] Prediction of non-responders to oral appliance treatment of obstructive sleep apnea: a pilot study
    Ulrik Leidland Opsahl
    Morten Berge
    Sverre Lehmann
    Bjørn Bjorvatn
    Anders Johansson
    Sleep and Breathing, 2025, 29 (2) : 159
  • [27] Adjustable Thermoplastic Oral Appliance Versus Positive Airway Pressure for Obstructive Sleep Apnea
    Banhiran, Wish
    Assanasen, Paraya
    Nopmaneejumrudlers, Cherdchai
    Nujchanart, Nongyoaw
    Srechareon, Wimontip
    Chongkolwatana, Cheerasook
    Metheetrairut, Choakchai
    LARYNGOSCOPE, 2018, 128 (02) : 516 - 522
  • [28] The value of auto-adjustable CPAP devices in pressure titration and treatment of patients with obstructive sleep apnea syndrome
    Hertegonne, Katrien
    Bauters, Fre
    SLEEP MEDICINE REVIEWS, 2010, 14 (02) : 115 - 119
  • [29] Does CPAP treatment in mild obstructive sleep apnea affect blood pressure?
    Jaimchariyatam, Nattapong
    Rodriguez, Carlos L.
    Budur, Kumar
    SLEEP MEDICINE, 2010, 11 (09) : 837 - 842
  • [30] Videoendoscopic diagnosis for predicting the response to oral appliance therapy in severe obstructive sleep apnea
    Sasao, Yasuhiro
    Nohara, Kanji
    Okuno, Kentaro
    Nakamura, Yuki
    Sakai, Takayoshi
    SLEEP AND BREATHING, 2014, 18 (04) : 809 - 815