Liver Computed Tomography With Low Tube Voltage and Model-Based Iterative Reconstruction Algorithm for Hepatic Vessel Evaluation in Living Liver Donor Candidates

被引:17
作者
Hur, Bo Yun [1 ]
Lee, Jeong Min [2 ,3 ]
Joo, Ijin [2 ]
Yu, Mi Hye [4 ]
Yoon, Jeong Hee [2 ]
Han, Joon Koo [2 ,3 ]
Choi, Byung Ihn [2 ,3 ]
机构
[1] SMG SNU Boramae Med Ctr, Dept Radiol, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[3] Seoul Natl Univ Hosp, Inst Radiat Med, Seoul 110744, South Korea
[4] Konkuk Univ, Med Ctr, Dept Radiol, Seoul, South Korea
关键词
model-based iterative reconstruction; low tube voltage; CT for living liver donors; FILTERED BACK-PROJECTION; RADIATION-DOSE REDUCTION; IMPROVED IMAGE QUALITY; CT ANGIOGRAPHY; HEPATOCELLULAR-CARCINOMA; ABDOMINAL CT; IMPROVED DELINEATION; MULTIDETECTOR CT; ARTERIAL PHASE; 120; KVP;
D O I
10.1097/RCT.0b013e3182ab6cc0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of this study was to investigate the image quality and diagnostic performance of model-based iterative reconstruction (MBIR) for hepatic vessel evaluation on low-tube-voltage (100 kilovolt [peak]) liver computed tomography (CT) for living donors. Methods: Fifty-one liver donor candidates (low-kilovolt group) underwent low-tube-voltage CT, which was reconstructed using filtered back projection, adaptive statistical iterative reconstruction, and MBIR. Additional 51 donor candidates who underwent 120-kilovolt (peak) CT using FBP were selected as matching control (standard group). The volume CT dose index, image noise, contrast-to-noise ratios, diagnostic accuracy, and confidence of hepatic vasculatures were evaluated. Results: Significant dose reduction was obtained with low-tube-voltage CT. The MBIR images of the low-kilovolt group showed significantly lower image noise and higher contrast-to-noise ratios than did the other image sets (P < 0.001). Regarding diagnostic accuracy and confidence of hepatic vessel anatomic variations with surgical correlation, the MBIR images provided results equivalent to those of other images (P > 0.05). Conclusions: Low-tube-voltage liver CT using MBIR may increase image quality and preserve diagnostic performance of hepatic vessel evaluation at reduced radiation dose.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 49 条
  • [1] A retrospective evaluation of causes of exempting living liver donors in an Egyptian centre
    Aboueisha, Hisham
    Elbaz, Tamer
    Hosny, Karim
    Bravo, Ahmed
    Elshazli, Mostafa
    Salah, Ayman
    Korashi, Ezz
    Hosny, Adel
    [J]. ARAB JOURNAL OF GASTROENTEROLOGY, 2013, 14 (01) : 10 - 13
  • [2] Evolution of liver transplantation in Europe: Report of the European liver transplant registry
    Adam, P
    McMaster, P
    O'Grady, JG
    Castaing, D
    Klempnauer, JL
    Jamieson, N
    Neuhaus, P
    Lerut, J
    Salizzoni, M
    Pollard, S
    Muhlbacher, F
    Rogiers, X
    Valdecasas, JCG
    Berenguer, J
    Jaeck, D
    Gonzalez, EM
    [J]. LIVER TRANSPLANTATION, 2003, 9 (12) : 1231 - 1243
  • [3] Portal venous variations - Prevalence with contrast-enhanced helical CT
    Akgul, E
    Inal, M
    Soyupak, S
    Binokay, F
    Aksungur, E
    Oguz, M
    [J]. ACTA RADIOLOGICA, 2002, 43 (03) : 315 - 319
  • [4] Dose reduction in pediatric CT: A rational approach
    Boone, JM
    Geraghty, EM
    Seibert, JA
    Wootton-Gorges, SL
    [J]. RADIOLOGY, 2003, 228 (02) : 352 - 360
  • [5] Boone JM, 2011, AAPM 2011
  • [6] Living donor liver transplantation in adults:: Outcome in Europe
    Broelsch, CE
    Malagó, M
    Testa, G
    Gamazo, CV
    [J]. LIVER TRANSPLANTATION, 2000, 6 (06) : S64 - S65
  • [7] Assessment of a Model-Based, Iterative Reconstruction Algorithm (MBIR) Regarding Image Quality and Dose Reduction in Liver Computed Tomography
    Chang, Won
    Lee, Jeong Min
    Lee, Kyunghee
    Yoon, Jeong Hee
    Yu, Mi Hye
    Han, Joon Koo
    Choi, Byung Ihn
    [J]. INVESTIGATIVE RADIOLOGY, 2013, 48 (08) : 598 - 606
  • [8] Recommendations for liver transplantation for hepatocellular carcinoma: an international consensus conference report
    Clavien, Pierre-Alain
    Lesurtel, Mickael
    Bossuyt, Patrick M. M.
    Gores, Gregory J.
    Langer, Bernard
    Perrier, Arnaud
    [J]. LANCET ONCOLOGY, 2012, 13 (01) : E11 - E22
  • [9] Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study
    Deak, Zsuzsanna
    Grimm, Jochen M.
    Treitl, Marcus
    Geyer, Lucas L.
    Linsenmaier, Ulrich
    Koerner, Markus
    Reiser, Maximilian F.
    Wirth, Stefan
    [J]. RADIOLOGY, 2013, 266 (01) : 197 - 206
  • [10] Complications in 100 living-liver donors
    Grewal, HP
    Thistlethwaite, JR
    Loss, GE
    Fisher, JS
    Cronin, DC
    Siegel, CT
    Newell, KA
    Bruce, DS
    Woodle, ES
    Brady, L
    Kelly, S
    Boone, P
    Oswald, K
    Millis, JM
    [J]. ANNALS OF SURGERY, 1998, 228 (02) : 214 - 219