Long-term requirement for pacemaker implantation after cardiac valve replacement surgery

被引:47
作者
Leyva, Francisco [1 ]
Qiu, Tian [2 ]
McNulty, David [2 ]
Evison, Felicity [2 ]
Marshall, Howard [3 ]
Gasparini, Maurizio [4 ]
机构
[1] Aston Univ, Aston Med Sch, Aston Med Res Inst, Birmingham, W Midlands, England
[2] Queen Elizabeth Hosp, Qual & Outcomes Res Unit, Birmingham, W Midlands, England
[3] Queen Elizabeth Hosp, Birmingham, W Midlands, England
[4] Humanitas Res Hosp IRCCS, Electrophysiol & Pacing Unit, Rozzano Milano, Italy
关键词
Aortic valve replacement; Mitral valve replacement; Tricuspid valve replacement; Permanent pacemaker; Transcatheter aortic valve replacement; RISK-FACTORS; HEART-BLOCK; LESIONS; BUNDLE;
D O I
10.1016/j.hrthm.2016.11.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The risk of permanent pacemaker implantation (PPI) after cardiac valve replacement surgery is thought to be highest in the postoperative period. Long-term risks are uncertain. OBJECTIVE The purpose of this study was to determine rates and timing of PPI after cardiac valve replacement surgery. METHODS We compared PPI rates of patients undergoing aortic valve replacement (AVR; n = 111,674), mitral valve replacement (MVR; n = 18,402), AVR + MVR (n = 5166), AVR + MVR + tricuspid valve replacement (TVR; n = 114), or coronary artery bypass surgery (CABG) without valve replacement (n = 249,742). RESULTS Over a period of 14 years (median 3.9 years; interquartile range 1.1-7.4 years), cumulative PPI rates were 3.07-7.6 times higher (P < .001 for all) than after CABG, depending on the number of valves replaced. PPI risks after AVR were higher that those after MVR (hazard ratio [HR] 1.22; 95% confidence interval [CI] 1.161.28), AVR + MVR (HR 1.52; 950/0 CI 1.40-1.65), and AVR + MVR + TVR (HR 2.22; 950/a CI 1.40-3.53), independent of known confounders. Cumulative PPI hazard rates from the postoperative period to 10 years after surgery increased after AVR (4.22%14.4%), MVR (4.38%-15.6%), AVR + MVR (5.59%-18.3%), and AVR + MVR + TVR (7.89 /0-25.9 /0) (P <.001 for all). Age, male sex, emergency admission, and preexisting diabetes mellitus, renal impairment, and heart failure were independent predictors of PPI (P < .001 for all). CONCLUSION Valve replacement surgery was associated with a long-term risk of PPI. This was particularly high after dual and triple valve replacements. Age, male sex, emergency admission, and preexisting diabetes mellitus, heart failure, and renal impairment were independent predictors of PPI.
引用
收藏
页码:529 / 534
页数:6
相关论文
共 26 条
[1]   Pacemaker dependency after isolated aortic valve replacement: do conductance disorders recover over time? [J].
Baraki, Hassina ;
Al Ahmad, Ammar ;
Jeng-Singh, Stefan ;
Saito, Shunsuke ;
Schmitto, Jan Dieter ;
Fleischer, Bernhard ;
Haverich, Axel ;
Kutschka, Ingo .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 16 (04) :476-481
[2]   Long-Term Survival After Aortic Valve Replacement Among High-Risk Elderly Patients in the United States Insights From the Society of Thoracic Surgeons Adult Cardiac Surgery Database, 1991 to 2007 [J].
Brennan, J. Matthew ;
Edwards, Fred H. ;
Zhao, Yue ;
O'Brien, Sean M. ;
Douglas, Pamela S. ;
Peterson, Eric D. .
CIRCULATION, 2012, 126 (13) :1621-1629
[3]  
Burke A P, 1994, J Heart Valve Dis, V3, P10
[4]  
Capita plc, 2014, QUAL CLIN COD NHS
[5]  
DOUEIHI RZ, 1992, ACTA CARDIOL, V47, P157
[6]   The bioprosthesis type and size influence the postoperative incidence of permanent pacemaker implantation in patients undergoing aortic valve surgery [J].
Elahi, Maqsood ;
Usmaan, Khalid .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 15 (02) :113-118
[7]   Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry [J].
Eltchaninoff, Helene ;
Prat, Alain ;
Gilard, Martine ;
Leguerrier, Alain ;
Blanchard, Didier ;
Fournial, Gerard ;
Iung, Bernard ;
Donzeau-Gouge, Patrick ;
Tribouilloy, Christophe ;
Debrux, Jean-Louis ;
Pavie, Alain ;
Gueret, Pascal .
EUROPEAN HEART JOURNAL, 2011, 32 (02) :191-197
[8]   Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement [J].
Erdogan, HB ;
Kayalar, N ;
Ardal, H ;
Omeroglu, SN ;
Kirali, K ;
Guler, M ;
Akinci, E ;
Yakut, C .
JOURNAL OF CARDIAC SURGERY, 2006, 21 (03) :211-215
[9]   LESIONS OF CONDUCTION TISSUE COMPLICATING AORTIC VALVULAR REPLACEMENT [J].
FUKUDA, T ;
HAWLEY, RL ;
EDWARDS, JE .
CHEST, 1976, 69 (05) :605-614
[10]   Frequency of Conduction Disturbances After Transcatheter Implantation of an Edwards Sapien Aortic Valve Prosthesis [J].
Godin, Matthieu ;
Eltchaninoff, Helene ;
Furuta, Akira ;
Tron, Christophe ;
Anselme, Frederic ;
Bejar, Karim ;
Sanchez-Giron, Carlos ;
Bauer, Fabrice ;
Litzler, Pierre-Yves ;
Bessou, Jean-Paul ;
Cribier, Alain .
AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (05) :707-712