Multidetector CT: Diagnostic impact of slice thickness on detection of hypervascular hepatocellular carcinoma

被引:61
作者
Kawata, S
Murakami, T
Kim, T
Hori, M
Federle, MP
Kumano, S
Sugihara, E
Makino, S
Nakamura, H
Kudo, M
机构
[1] Osaka Univ, Grad Sch Med D1, Dept Radiol, Suita, Osaka 5650871, Japan
[2] Univ Pittsburgh, Med Ctr, Dept Radiol, Pittsburgh, PA 15213 USA
[3] Gen Elect, Yokogawa Med Syst, Hino, Tokyo 1918503, Japan
关键词
D O I
10.2214/ajr.179.1.1790061
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to evaluate the diagnostic impact of varying slice thickness on multidetector CT to optimize detection of hypervascular hepatocellular carcinoma. MATERIALS AND METHODS. Forty-three patients with 87 hypervascular hepatocellular carcinomas (diameter: range, 3-80 mm; mean, 22 mm) and 19 patients with either chronic hepatitis or liver cirrhosis and without hepatocellular carcinoma who had undergone early arterial and late arterial phase imaging of the entire liver on multidetector CT were retrospectively enrolled in this study. The detector row configuration was 2.5 x 4 mm, the pitch was 6, and the scanning time was 10.5 sec for each phase. All patients received contrast medium (2 mL/kg of body weight) at a rate of 5 mL/sec; the mean scanning delay for the early arterial phase was 19.0 sec, and the mean delay for the late arterial phase was 34.5 sec. Eighty 2.5-mm-thick reconstruction images, forty 5-mm-thick reconstruction images, and twenty-six 7.5-mm-thick reconstruction images were obtained for each phase. Each image set was interpreted separately by three observers to detect hypervascular hepatocellular carcinoma by viewing images on a workstation monitor. Sensitivity, positive predictive value, and area under the receiver operating characteristic curve (A(z)) were calculated. We used retrospectively excellent follow-up and imaging or pathologic proof as the gold standard. RESULTS. The mean sensitivity and positive predictive value for hypervascular hepatocellular carcinoma were 76% and 69% on 2.5-mm images, 73% and 69% on 5-mm, images, and 67% and 76% on 7.5-mm images, respectively. No significant difference in sensitivity among the images was detected, except by one observer who reported a significant difference in the sensitivity between 2.5- and 7.5-mm images (p < 0.05) and between 5- and 7.5-mm images (p < 0.05). The mean A(z) values were 0.79, 0.80, and 0.78 for 2.5-, 5-, and 7.5-mm images, respectively. No significant difference in A(z) values among the images obtained with different slice thicknesses was detected. CONCLUSION. For multidetector CT identification of hypervascular hepatocellular carcinoma, we found little or no advantage in reducing slice thickness to less than 5 mm.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 25 条
  • [1] *41 WORLD MED ASS, 1990, B PAN AM HLTH ORG, V24, P606
  • [2] Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT
    Baron, RL
    Oliver, JH
    Dodd, GD
    Nalesnik, M
    Holbert, BL
    Carr, B
    [J]. RADIOLOGY, 1996, 199 (02) : 505 - 511
  • [3] Basilico R, 2000, RADIOLOGY, V217, P368
  • [4] Multiphase hepatic CT with a multirow detector CT scanner
    Foley, WD
    Mallisee, TA
    Hohenwalter, MD
    Wilson, CR
    Quiroz, FA
    Taylor, AJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (03) : 679 - 685
  • [5] DUAL-PHASE HELICAL CT OF THE LIVER - VALUE OF ARTERIAL PHASE SCANS IN THE DETECTION OF SMALL (LESS-THAN-OR-EQUAL-TO-1.5-CM) MALIGNANT HEPATIC NEOPLASMS
    HOLLETT, MD
    JEFFREY, RB
    NINOMURCIA, M
    JORGENSEN, MJ
    HARRIS, DP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (04) : 879 - 884
  • [6] Four multidetector-row helical CT: Image quality and volume coverage speed
    Hu, H
    He, HD
    Foley, WD
    Fox, SH
    [J]. RADIOLOGY, 2000, 215 (01) : 55 - 62
  • [7] Impact of multidetector CT on donor selection and surgical planning before living adult right lobe liver transplantation
    Kamel, IR
    Kruskal, JB
    Pomfret, EA
    Keogan, MT
    Warmbrand, G
    Raptopoulos, V
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) : 193 - 200
  • [8] Detection and characterization of hepatic tumors: Value of combined helical CT hepatic arteriography and CT during arterial portography
    Kanematsu, M
    Hoshi, H
    Imaeda, T
    Murakami, T
    Inaba, Y
    Yokoyama, R
    Nakamura, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1193 - 1198
  • [9] DETECTION OF HYPERVASCULAR HEPATOCELLULAR-CARCINOMA BY DYNAMIC MRI AND DYNAMIC SPIRAL CT
    KIM, T
    MURAKAMI, T
    OI, H
    MATSUSHITA, M
    KISHIMOTO, H
    IGARASHI, H
    NAKAMURA, H
    OKAMURA, J
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (06) : 948 - 954
  • [10] Kopka L, 2000, RADIOLOGY, V217, P367