Intracranial aneurysm stenting:: Follow-up with MR angiography

被引:51
|
作者
Loevblad, Karl-Olof
Yilmaz, Hasan
Chouiter, Amine
Ruiz, Diego San Millan
Abdo, German
Bijlenga, Philippe
de Tribolet, Nicolas
Ruefenacht, Daniel A.
机构
[1] Univ Hosp Geneva, Div Neuroradiol, Radiol Dept SRRI, CH-1211 Geneva 14, Switzerland
[2] Univ Hosp Geneva, Dept Neurosurg, CH-1211 Geneva, Switzerland
关键词
stent; MRA; aneurysm; artifact vessel;
D O I
10.1002/jmri.20642
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intracranial stenting is increasingly being used to treat intracranial aneurysms and stenoses. We wanted to assess the utility of magnetic resonance angiography (MRA) in the follow-up of patients treated with various types of intracranial stents and to assess the utility of performing gadolinium-enhanced MRA. A total of 19 patients having undergone intracranial stenting for aneurysms were imaged by MRI at 1.5T. A total of 20 stents were placed in 19 patients. In addition to conventional T2 and diffusion-weighted MRI, 3D time-of-flight MRA was performed before and after contrast administration. In the case of metallic INX stents (N = 7), there was a signal drop at the level of the vessel which did not allow to evaluating the parent vessel, whereas this was visible in Nitinol stents (N = 8). Additionally a stent with a wire had a small artifact (N = 3)., Contrast administration also improved vessel lumen visualization. In the case of Nitinol stents, MRA can be used reliably demonstrate the vessel lumen after intracranial stenting. The use of postcontrast 3D time-of-flight imaging helps improve the intralumiinal definition.
引用
收藏
页码:418 / 422
页数:5
相关论文
共 50 条
  • [41] BLINDED PROSPECTIVE EVALUATION OF SENSITIVITY OF MR-ANGIOGRAPHY TO KNOWN INTRACRANIAL ANEURYSMS - IMPORTANCE OF ANEURYSM SIZE
    HUSTON, J
    NICHOLS, DA
    LUETMER, PH
    GOODWIN, JT
    MEYER, FB
    WIEBERS, DO
    WEAVER, AL
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (09) : 1607 - 1614
  • [42] The ability of plain radiography to predict intracranial aneurysm occlusion instability during follow-up of endosaccular treatment with Gugliemi detachable coils
    Connor, SEJ
    West, RJ
    Yates, DA
    NEURORADIOLOGY, 2001, 43 (08) : 680 - 686
  • [43] A novel self-expanding shape memory polymer coil for intracranial aneurysm embolization: 1 year follow-up in Chile
    Echeverria, Daniel
    Rivera, Rodrigo
    Giacaman, Pablo
    Sordo, Juan Gabriel
    Einersen, Martin
    Badilla, Lautaro
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2023, 15 (08) : 781 - 786
  • [44] Portal vein aneurysm;: CT, MR and MR angiography appearances
    Arda, K
    Kizilkanat, KT
    Tosun, Ö
    Ögdüm, D
    ACTA GASTRO-ENTEROLOGICA BELGICA, 2002, 65 (02): : 136 - 138
  • [45] Follow-up of intracranial aneurysms treated by flow diverter: comparison of three-dimensional time-of-flight MR angiography (3D-TOF-MRA) and contrast-enhanced MR angiography (CE-MRA) sequences with digital subtraction angiography as the gold standard
    Attali, Jonathan
    Benaissa, Azzedine
    Soize, Sebastien
    Kadziolka, Krzysztof
    Portefaix, Christophe
    Pierot, Laurent
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (01) : 81 - 86
  • [46] The effect of Neuroform stent-assisted coil embolization of wide-necked intracranial aneurysms and clinical factors on progressive aneurysm occlusion on angiographic follow-up
    Gu, Da-Qun
    Zhang, Xin
    Luo, Bin
    Long, Xiao-Ao
    Duan, Chuan-Zhi
    JOURNAL OF CLINICAL NEUROSCIENCE, 2013, 20 (02) : 238 - 241
  • [47] The sensitivity and specificity of TOF-MRA compared with DSA in the follow-up of treated intracranial aneurysms
    Xiang, Sishi
    Fan, Fu
    Hu, Peng
    Yang, Kun
    Zhai, Xiaodong
    Geng, Jiewen
    Ji, Zhe
    Lu, Jie
    Zhang, Hongqi
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (12) : 1172 - +
  • [48] Follow-up after undersized dilatation of targeted lesions in carotid artery stenting
    Murakami, Mamoru
    Hatano, Taketo
    Miyakoshi, Akinori
    Arai, Daisuke
    Yamaguchi, Susumu
    Ogino, Eiji
    Ohtani, Ryo
    Tsukahara, Tetsuya
    BRITISH JOURNAL OF NEUROSURGERY, 2015, 29 (05) : 661 - 667
  • [49] 3-Year Follow-Up after Endovascular Aneurysm Treatment with Silk® Flow Diverter
    Ringelstein, A.
    Schlamann, M.
    Goericke, S. L.
    Moenninghoff, C.
    Sandalcioglu, I. E.
    El Hindy, N.
    Forsting, M.
    Wanke, I.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (04): : 328 - 332
  • [50] Socioeconomic disparities in surveillance and follow-up of patients with thoracic aortic aneurysm
    Shang, Michael
    Weininger, Gabe
    Mori, Makoto
    Kahler-Quesada, Arianna
    Degife, Ellelan
    Brooks, Cornell
    Yousef, Sameh
    Williams, Matthew
    Assi, Roland
    Geirsson, Arnar
    Vallabhajosyula, Prashanth