Cross-linked Compared with Historical Polyethylene in THA: An 8-year Clinical Study

被引:56
作者
Geerdink, Carel H. [1 ,2 ]
Grimm, Bernd [2 ]
Vencken, Wendy [2 ]
Heyligers, Ide C. [2 ]
Tonino, Alphons J. [2 ]
机构
[1] Ikazia Hosp, Dept Orthopaed Surg, NL-3083 AN Rotterdam, Netherlands
[2] Atrium Med Ctr, Dept Orthopaed Surg, Heerlen, Netherlands
关键词
TOTAL HIP-ARTHROPLASTY; MOLECULAR-WEIGHT POLYETHYLENE; IN-VIVO WEAR; FOLLOW-UP; RADIOSTEREOMETRIC ANALYSIS; PELVIC OSTEOLYSIS; FEMORAL-HEAD; CONVENTIONAL POLYETHYLENE; ACETABULAR COMPONENT; UNCEMENTED SOCKETS;
D O I
10.1007/s11999-008-0628-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Wear particle-induced osteolysis is a major cause of aseptic loosening in THA. Increasing wear resistance of polyethylene (PE) occurs by increasing the cross-link density and early reports document low wear rates with such implants. To confirm longer-term reductions in wear we compared cross-linked polyethylene (irradiation in nitrogen, annealing) with historical polyethylene (irradiation in air) in a prospective, randomized clinical study involving 48 patients who underwent THAs with a minimum followup of 7 years (mean, 8 years; range, 7-9 years). The insert material was the only variable. The Harris hip score, radiographic signs of osteolysis, and polyethylene wear were recorded annually. Twenty-three historical and 17 moderately cross-linked polyethylene inserts were analyzed (five patients died, three were lost to followup). At 8 years, the wear rate was lower for cross-linked polyethylene (0.088 +/- A 0.03 mm/year) than for the historical polyethylene (0.142 +/- A 0.07 mm/year). This reduction (38%) did not diminish with time (33% at 5 years). Acetabular cyst formation was less frequent (39% versus 12%), affected fewer DeLee and Charnley zones (17% versus 4%), and was less severe for the cross-linked polyethylene. The only revision was for an aseptically loose cup in the historical polyethylene group. Moderately cross-linked polyethylene maintained its wear advantage with time and produced less osteolysis, showing no signs of aging at mid-term followup. Level of Evidence: Level I, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:979 / 984
页数:6
相关论文
共 43 条
[1]  
[Anonymous], 2003, ANN BOOK ASTM STAND, pD 6751
[2]  
Barrack RL, 1997, CLIN ORTHOP RELAT R, P211
[3]   Minimum 6-year followup of highly cross-linked polyethylene in THA [J].
Bragdon, Charles R. ;
Kwon, Young Min ;
Geller, Jeffrey A. ;
Greene, Meridith E. ;
Freiberg, Andrew A. ;
Harris, William H. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :122-127
[4]   Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36-vs 28-mm femoral heads [J].
Bragdon, Charles R. ;
Greene, Meridith E. ;
Freiberg, Andrew A. ;
Harris, William H. ;
Malchau, Henrik .
JOURNAL OF ARTHROPLASTY, 2007, 22 (06) :125-129
[5]   Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty [J].
Castoldi, Filippo ;
Rossi, Roberto ;
La Russa, Massimo ;
Sibelli, Pierro ;
Rossi, Paolo ;
Ranawat, Amar S. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (03) :363-368
[6]   Radiographic definition of pelvic osteolysis following total hip arthroplasty [J].
Claus, AM ;
Engh, CA ;
Sychterz, CJ ;
Xenos, JS ;
Orishimo, KF ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (08) :1519-1526
[7]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[8]   The Otto Aufranc Award -: Highly cross-linked polyethylene in Total Hip Arthroplasty -: Randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis [J].
Digas, G ;
Kärrholm, J ;
Thanner, J ;
Malchau, H ;
Herberts, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :6-16
[9]   5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets -: Two randomized studies using radiostereometric analysis [J].
Digas, Georgios ;
Karrholm, Johan ;
Thanner, Jonas ;
Herberts, Peter .
ACTA ORTHOPAEDICA, 2007, 78 (06) :746-754
[10]   Clinical performance of a durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years [J].
Dorr, LD ;
Wan, ZN ;
Shahrdar, C ;
Sirianni, L ;
Boutary, M ;
Yun, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08) :1816-1821