Tessellated fundus appearance and its association with myopic refractive error

被引:15
作者
Jagadeesh, Divya [1 ,2 ]
Philip, Krupa [3 ]
Naduvilath, Thomas J. [1 ,2 ]
Fedtke, Cathleen [1 ,2 ]
Jong, Monica [1 ,2 ]
Zou, Haidong [4 ]
Sankaridurg, Padmaja [1 ,2 ]
机构
[1] Brien Holden Vis Inst, Sydney, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Univ Buraimi, Buraimi, Oman
[4] Shanghai Eye Dis Prevent & Treatment Ctr, Shanghai, Peoples R China
关键词
axial length; myopia; myopic maculopathy; refractive error; tessellated fundus; visual acuity; RISK-FACTORS; MACULOPATHY; PREVALENCE; CLASSIFICATION; POPULATION; GLAUCOMA; CHINESE;
D O I
10.1111/cxo.12822
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The appearance of tessellated fundus in an eye may act as a marker in identifying visual performance, degree of myopia or risk of progression of myopia in a given eye. A systematic literature search using key words was performed using PubMed, Web of Science and Google Scholar and of the 832 studies identified, 10 full-length articles, which met the inclusion criteria, were considered for review. The primary outcome measures were association of tessellated fundus with: (i) visual acuity, (ii) refractive error, (iii) axial length, (iv) choroidal thickness and (v) future progression of myopia when compared to either no myopic maculopathy, or more severe myopic maculopathy. There was no significant difference in the visual acuity noted between eyes with normal fundus and tessellated fundus appearance. Compared to eyes with tessellated fundus, eyes with more severe myopic maculopathy had a four-line decrease in best-corrected visual acuity, more myopia (mean difference 2.75 D, range 0.28-5.78 D) and a longer axial length (mean difference 2 mm, range 2.29 to 1.71 mm). Eyes with tessellated fundus generally exhibited a significant decrease in choroidal thickness compared to eyes with no maculopathy. In mostly older individuals, eyes with tessellated fundus had a better outcome with respect to visual acuity, degree of myopia and axial length compared to other severe myopic maculopathies, but had a worse outcome for choroidal thickness and degree of myopia, compared to eyes with no myopic maculopathy. The features such as reduced choroidal thickness combined with a predilection to infra-temporal and parapapillary regions may indicate regions of stress that are prone to more stretching/atrophic changes. This systematic review demonstrated an association of tessellated fundus with visual acuity, refractive error, axial length and choroidal thickness and hence emphasises the documentation of the presence and location of tessellated fundus appearance that may help in predicting the progression of myopia.
引用
收藏
页码:378 / 384
页数:7
相关论文
共 22 条
[1]   The types and severity of high myopic maculopathy in Chinese patients [J].
Chen, Hui ;
Wen, Feng ;
Li, Haitao ;
Zuo, Chengguo ;
Zhang, Xiongze ;
Huang, Shizhou ;
Luo, Guangwei .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2012, 32 (01) :60-67
[2]   Prevalence and Associated Risk Factors of Myopic Maculopathy in Elderly Chinese: The Shihpai Eye Study [J].
Chen, Shih-Jen ;
Cheng, Ching-Yu ;
Li, An-Fei ;
Peng, Kai-Ling ;
Chou, Pesus ;
Chiou, Shih-Hwa ;
Hsu, Wen-Ming .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (08) :4868-4873
[3]   Progression of Myopic Maculopathy during 18-Year Follow-up [J].
Fang, Yuxin ;
Yokoi, Tae ;
Nagaoka, Natsuko ;
Shinohara, Kosei ;
Onishi, Yuka ;
Ishida, Tomoka ;
Yoshida, Takeshi ;
Xu, Xian ;
Jonas, Jost B. ;
Ohno-Matsui, Kyoko .
OPHTHALMOLOGY, 2018, 125 (06) :863-877
[4]   Long-term Pattern of Progression of Myopic Maculopathy A Natural History Study [J].
Hayashi, Kengo ;
Ohno-Matsui, Kyoko ;
Shimada, Noriaki ;
Moriyama, Muka ;
Kojima, Ariko ;
Hayashi, Wakako ;
Yasuzumi, Kenjiro ;
Nagaoka, Natsuko ;
Saka, Natsuko ;
Yoshida, Takeshi ;
Tokoro, Takashi ;
Mochizuki, Manabu .
OPHTHALMOLOGY, 2010, 117 (08) :1595-U174
[5]   Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050 [J].
Holden, Brien A. ;
Fricke, Timothy R. ;
Wilson, David A. ;
Jong, Monica ;
Naidoo, Kovin S. ;
Sankaridurg, Padmaja ;
Wong, Tien Y. ;
Naduvilath, Thomas J. ;
Resnikoff, Serge .
OPHTHALMOLOGY, 2016, 123 (05) :1036-1042
[6]   Myopic Maculopathy and Optic Disc Changes in Highly Myopic Young Asian Eyes and Impact on Visual Acuity [J].
Koh, Victor ;
Tan, Colin ;
Tan, Pei Ting ;
Tan, Marcus ;
Balla, Vinay ;
Nah, Gerard ;
Cheng, Ching-Yu ;
Ohno-Matsui, Kyoko ;
Tan, Mellisa M. H. ;
Yang, Adeline ;
Zhao, Paul ;
Wong, Tien Yin ;
Saw, Seang-Mei .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 164 :69-79
[7]   The relationship between glaucoma and myopia - The blue mountains eye study [J].
Mitchell, P ;
Hourihan, F ;
Sandbach, J ;
Wang, JJ .
OPHTHALMOLOGY, 1999, 106 (10) :2010-2015
[8]   International Photographic Classification and Grading System for Myopic Maculopathy [J].
Ohno-Matsui, Kyoko ;
Kawasaki, Ryo ;
Jonas, Jost B. ;
Cheung, Chui Ming Gemmy ;
Saw, Seang-Mei ;
Verhoeven, Virginie J. M. ;
Klaver, Caroline C. W. ;
Moriyama, Muka ;
Shinohara, Kosei ;
Kawasaki, Yumiko ;
Yamazaki, Mai ;
Meuer, Stacy ;
Ishibashi, Tatsuro ;
Yasuda, Miho ;
Yamashita, Hidetoshi ;
Sugano, Akira ;
Wang, Jie Jin ;
Mitchell, Paul ;
Wong, Tien Yin .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (05) :877-883
[9]   Practical applications to modify and control the development of ametropia [J].
Sankaridurg, P. R. ;
Holden, B. A. .
EYE, 2014, 28 (02) :134-141
[10]   Male circumcision for prevention of heterosexual acquisition of HIV in men [J].
Siegfried, Nandi ;
Muller, Martie ;
Deeks, Jonathan J. ;
Volmink, Jimmy .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2009, (02)