Feasibility of Deep Learning-Based Noise and Artifact Reduction in Coronal Reformation of Contrast-Enhanced Chest Computed Tomography

被引:0
作者
Kang, Eun-Ju [1 ]
Park, Hyoung Suk [2 ]
Jeon, Kiwan [2 ]
Lee, Ji Won [3 ,4 ]
Lim, Jae-Kwang [5 ]
机构
[1] Dong A Univ, Coll Med, Dept Radiol, 1,3 Ga Dongdaesin Dong, Busan 49201, South Korea
[2] Natl Inst Math Sci, Div Med Math, Daejeon, South Korea
[3] Pusan Natl Univ, Sch Med, Pusan Natl Univ Hosp, Dept Radiol, Busan, South Korea
[4] Med Res Inst, Busan, South Korea
[5] Kyungpook Natl Univ, Sch Med, Dept Radiol, Daegu, South Korea
关键词
chest; tomography x-ray; image reconstruction; deep learning; artificial intelligence; MOTION-CORRECTION ALGORITHM; ITERATIVE RECONSTRUCTION; IMAGE QUALITY; CT ANGIOGRAPHY; NETWORK;
D O I
10.1097/RCT.0000000000001326
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to evaluate the feasibility of a deep learning method for imaging artifact and noise reduction in coronal reformation of contrast-enhanced chest computed tomography (CT). Methods: A total of 19,052 coronal reformatted chest CT images of 110 CT image sets (55 pairs of concordant 16- and 320-row CT image sets) were included and used to train a deep learning algorithm for artifact and noise correction. For internal validation, 4093 coronal reformatted CT images of 25 patients from 16-row CT images underwent correction processing. For external validation, chest CT images of 30 patients (1028 coronal reformatted CT images), acquired in other institutions using different scanners, were subjected to correction processing. For both validations, image quality was compared between original ("CTorigin") and deep learning-based corrected ("CTcorrect") CTimages. Quantitative analysis for stair-step artifact (coefficient of variance of CT density on coronal reformation), image noise, signal-to-noise ratio, and contrast-to-noise ratio were evaluated. Subjective image quality scores were assigned for image contrast, artifact, and conspicuity of major structures. Results: CTcorrect showed significantly reduced stair-step artifact (mean coefficient of variance: CTorigin 7.35 +/- 2.0 vs CTcorrect 5.17 +/- 2.4, P < 0.001) and image noise and improved signal-to-noise ratio and contrast-to-noise ratio in the aorta, pulmonary artery, and liver, compared with those of CTorigin (P < 0.01). On subjective analysis, CTcorrect had higher image contrast, lower artifact, and better conspicuity than CTorigin. Most results of the external validation were consistent with those obtained from the internal validation, except for those concerning the pulmonary artery. Conclusions: Deep learning-based artifact correction significantly improved the image quality of coronal reformation chest CT by reducing image noise and artifacts.
引用
收藏
页码:593 / 603
页数:11
相关论文
共 36 条
[11]   Cycle-consistent adversarial denoising network for multiphase coronary CT angiography [J].
Kang, Eunhee ;
Koo, Hyun Jung ;
Yang, Dong Hyun ;
Seo, Joon Bum ;
Ye, Jong Chul .
MEDICAL PHYSICS, 2019, 46 (02) :550-562
[12]   Validation of Deep-Learning Image Reconstruction for Low-Dose Chest Computed Tomography Scan: Emphasis on Image Quality and Noise [J].
Kim, Joo Hee ;
Yoon, Hyun Jung ;
Lee, Eunju ;
Kim, Injoong ;
Cha, Yoon Ki ;
Bak, So Hyeon .
KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (01) :131-138
[13]  
Kingma D.P., 2015, 3 INT C LEARN REPR I
[14]   Deep learning-based metal artifact reduction using cycle-consistent adversarial network for intensity-modulated head and neck radiation therapy treatment planning [J].
Koike, Yuhei ;
Anetai, Yusuke ;
Takegawa, Hideki ;
Ohira, Shingo ;
Nakamura, Satoaki ;
Tanigawa, Noboru .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 :8-14
[15]   Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography [J].
Kuo, Yu ;
Lin, Yi-Yang ;
Lee, Rheun-Chuan ;
Lin, Chung-Jung ;
Chiou, Yi-You ;
Guo, Wan-Yuo .
MEDICINE, 2016, 95 (31)
[16]   Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medications [J].
Leipsic, Jonathon ;
Labounty, Troy M. ;
Hague, Cameron J. ;
Mancini, G. B. John ;
O'Brien, Julie M. ;
Wood, David A. ;
Taylor, Carolyn M. ;
Cury, Ricardo C. ;
Earls, James P. ;
Heilbron, Brett G. ;
Ajlan, Amr M. ;
Feuchtner, Gudrun ;
Min, James K. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) :164-171
[17]   Deep Learning Versus Iterative Reconstruction for CT Pulmonary Angiography in the Emergency Setting: Improved Image Quality and Reduced Radiation Dose [J].
Lenfant, Marc ;
Chevallier, Olivier ;
Comby, Pierre-Olivier ;
Secco, Gregory ;
Haioun, Karim ;
Ricolfi, Frederic ;
Lemogne, Brivael ;
Loffroy, Romaric .
DIAGNOSTICS, 2020, 10 (08)
[18]   DuDoNet: Dual Domain Network for CT Metal Artifact Reduction [J].
Lin, Wei-An ;
Liao, Haofu ;
Peng, Cheng ;
Sun, Xiaohang ;
Zhang, Jingdan ;
Luo, Jiebo ;
Chellappa, Rama ;
Zhou, Shaohua Kevin .
2019 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2019), 2019, :10504-10513
[19]   Current and Novel Imaging Techniques in Coronary CT [J].
Machida, Haruhiko ;
Tanaka, Isao ;
Fukui, Rika ;
Shen, Yun ;
Ishikawa, Takuya ;
Tate, Etsuko ;
Ueno, Eiko .
RADIOGRAPHICS, 2015, 35 (04) :991-1010
[20]   Potential contribution of multiplanar reconstruction (MPR) to computer-aided detection of lung nodules on MDCT [J].
Matsumoto, Sumiaki ;
Ohno, Yoshiharu ;
Yamagata, Hitoshi ;
Nogami, Munenobu ;
Kono, Atsushi ;
Sugimura, Kazuro .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (02) :366-370