Feasibility of Deep Learning-Based Noise and Artifact Reduction in Coronal Reformation of Contrast-Enhanced Chest Computed Tomography

被引:0
作者
Kang, Eun-Ju [1 ]
Park, Hyoung Suk [2 ]
Jeon, Kiwan [2 ]
Lee, Ji Won [3 ,4 ]
Lim, Jae-Kwang [5 ]
机构
[1] Dong A Univ, Coll Med, Dept Radiol, 1,3 Ga Dongdaesin Dong, Busan 49201, South Korea
[2] Natl Inst Math Sci, Div Med Math, Daejeon, South Korea
[3] Pusan Natl Univ, Sch Med, Pusan Natl Univ Hosp, Dept Radiol, Busan, South Korea
[4] Med Res Inst, Busan, South Korea
[5] Kyungpook Natl Univ, Sch Med, Dept Radiol, Daegu, South Korea
关键词
chest; tomography x-ray; image reconstruction; deep learning; artificial intelligence; MOTION-CORRECTION ALGORITHM; ITERATIVE RECONSTRUCTION; IMAGE QUALITY; CT ANGIOGRAPHY; NETWORK;
D O I
10.1097/RCT.0000000000001326
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to evaluate the feasibility of a deep learning method for imaging artifact and noise reduction in coronal reformation of contrast-enhanced chest computed tomography (CT). Methods: A total of 19,052 coronal reformatted chest CT images of 110 CT image sets (55 pairs of concordant 16- and 320-row CT image sets) were included and used to train a deep learning algorithm for artifact and noise correction. For internal validation, 4093 coronal reformatted CT images of 25 patients from 16-row CT images underwent correction processing. For external validation, chest CT images of 30 patients (1028 coronal reformatted CT images), acquired in other institutions using different scanners, were subjected to correction processing. For both validations, image quality was compared between original ("CTorigin") and deep learning-based corrected ("CTcorrect") CTimages. Quantitative analysis for stair-step artifact (coefficient of variance of CT density on coronal reformation), image noise, signal-to-noise ratio, and contrast-to-noise ratio were evaluated. Subjective image quality scores were assigned for image contrast, artifact, and conspicuity of major structures. Results: CTcorrect showed significantly reduced stair-step artifact (mean coefficient of variance: CTorigin 7.35 +/- 2.0 vs CTcorrect 5.17 +/- 2.4, P < 0.001) and image noise and improved signal-to-noise ratio and contrast-to-noise ratio in the aorta, pulmonary artery, and liver, compared with those of CTorigin (P < 0.01). On subjective analysis, CTcorrect had higher image contrast, lower artifact, and better conspicuity than CTorigin. Most results of the external validation were consistent with those obtained from the internal validation, except for those concerning the pulmonary artery. Conclusions: Deep learning-based artifact correction significantly improved the image quality of coronal reformation chest CT by reducing image noise and artifacts.
引用
收藏
页码:593 / 603
页数:11
相关论文
共 36 条
[1]   A Deep Learning-Enabled Iterative Reconstruction of Ultra-Low-Dose CT: Use of Synthetic Sinogram-based Noise Simulation Technique [J].
Ahn, Chul Kyun ;
Yang, Zepa ;
Heo, Changyong ;
Jin, Hyeongmin ;
Park, Byungjun ;
Kim, Jong Hyo .
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
[2]   Effect of Intracycle Motion Correction Algorithm on Image Quality and Diagnostic Performance of Computed Tomography Coronary Angiography in Patients with Suspected Coronary Artery Disease [J].
Carrascosa, Patricia ;
Deviggiano, Alejandro ;
Capunay, Carlos ;
De Zan, Macarena C. ;
Goldsmit, Alejandro ;
Rodriguez-Granillo, Gaston A. .
ACADEMIC RADIOLOGY, 2015, 22 (01) :81-86
[3]   Estimating Effective Dose for CT Using Dose-Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning [J].
Christner, Jodie A. ;
Kofler, James M. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :881-889
[4]   Clinical Utility of Multiplanar Reformation in Pulmonary CT Angiography [J].
Espinosa, Leandro A. ;
Kelly, Aine M. ;
Hawley, Colleen ;
Inampudi, Radha ;
Chughtai, Aamer ;
Agarwal, Prachi ;
Khalatbari, Shokoufeh ;
Myles, James ;
Kazerooni, Ella .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :70-75
[5]  
Goodfellow IJ, 2014, ADV NEUR IN, V27, P2672
[6]   Association between years since manufacture and utilization of computed tomography scanner in South Korea A cross-sectional study (a STROBE-compliant article) [J].
Hong, Jae-Seok .
MEDICINE, 2018, 97 (43)
[7]   Effect of Hybrid Kernel and Iterative Reconstruction on Objective and Subjective Analysis of Lung Nodule Calcification in Low-Dose Chest CT [J].
Hong, Seul Gi ;
Kang, Eun-Ju ;
Park, Jae Hyung ;
Choi, Won Jin ;
Lee, Ki-Nam ;
Kwon, Hee Jin ;
Ha, Dong-Ho ;
Kim, Dong Won ;
Kim, Sang Hyeon ;
Jo, Jeong-Hyun ;
Lee, Jongmin .
KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (05) :888-896
[8]   Deep Learning Cross-Phase Style Transfer for Motion Artifact Correction in Coronary Computed Tomography Angiography [J].
Jung, Sunghee ;
Lee, Soochahn ;
Jeon, Byunghwan ;
Jang, Yeonggul ;
Chang, Hyuk-Jae .
IEEE ACCESS, 2020, 8 :81849-81863
[9]   Artifacts at Cardiac CT: Physics and Solutions [J].
Kalisz, Kevin ;
Buethe, Ji ;
Saboo, Sachin S. ;
Abbara, Suhny ;
Halliburton, Sandra ;
Rajiah, Prabhakar .
RADIOGRAPHICS, 2016, 36 (07) :2064-2083