Behavior of CdTe and CdZnTe detectors following electron irradiation

被引:12
|
作者
Cavallini, A [1 ]
Fraboni, B
Dusi, W
Auricchio, N
Chirco, P
Zanarini, M
Siffert, P
Fougères, P
机构
[1] INFM, I-40126 Bologna, Italy
[2] Univ Bologna, Dept Phys, I-40126 Bologna, Italy
[3] CNR, Ist Tesre, I-40100 Bologna, Italy
[4] Univ Bologna, Dept Phys, I-40126 Bologna, Italy
[5] CNRS, Lab PHASE, F-67037 Strasbourg, France
[6] EURORAD, F-67037 Strasbourg, France
关键词
charge collection properties; radiation damage; solid-state detectors;
D O I
10.1109/TNS.2002.801683
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When exposed to an intense radiation field, the spectroscopic capabilities of room-temperature CdTe and CdZnTe detectors can be strongly altered by the remarkable injection of energy in the material structure due to the absorption of ionizing particles. In this paper, we report on the effects of electron irradiation on both CdTe and CdZnTe detectors. We have studied the detector response to electron irradiation through dark current measurements and by spectroscopic analyses at low and medium energies. The deep traps present in the material have been characterized by means of photo-induced current transient spectroscopy analyses, which allow for the determination of the trap apparent activation energy and capture cross section. The evolution of the trap parameters with increasing irradiation doses has been monitored and compared with the results already obtained by using other radiation sources.
引用
收藏
页码:1598 / 1602
页数:5
相关论文
共 50 条
  • [1] Irradiation-induced defects in CdTe and CdZnTe detectors
    Cavallini, A
    Fraboni, B
    Auricchio, N
    Caroli, E
    Dusi, W
    Chirco, P
    Morigi, MP
    Zanarini, M
    Hage-Ali, M
    Siffert, P
    Fougeres, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 392 - 399
  • [2] Electronic properties of traps induced by γ-irradiation in CdTe and CdZnTe detectors
    Cavallini, A
    Fraboni, B
    Chirco, P
    Morigi, MP
    Zanarini, M
    Auricchio, N
    Caroli, E
    Dusi, W
    Fougeres, P
    Hage-Ali, M
    Siffert, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03): : 558 - 566
  • [3] Characterization of CdTe/CdZnTe detectors
    Sato, G
    Takahashi, T
    Sugiho, M
    Kouda, M
    Mitani, T
    Nakazawa, K
    Okada, Y
    Watanabe, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1258 - 1263
  • [4] Characterization of CdTe/CdZnTe detectors
    Sato, G
    Takahashi, T
    Sugiho, M
    Kouda, M
    Watanabe, S
    Okada, Y
    Mitani, T
    Nakazawa, K
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2299 - 2303
  • [5] CdTe and CdZnTe detectors in nuclear medicine
    Scheiber, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03): : 513 - 524
  • [6] CdTe and CdZnTe detectors for timing measurements
    Okada, Y
    Takahashi, T
    Sato, G
    Watanabe, S
    Nakazawa, K
    Mori, K
    Makishima, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1986 - 1992
  • [7] Thermal treatments of CdTe and CdZnTe detectors
    Chattopadhyay, K
    Ma, X
    Ndap, JO
    Burger, A
    Schlesinger, TE
    Greaves, M
    Glass, HL
    Flint, JP
    James, RB
    HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 : 303 - 308
  • [8] Medical applications of CdTe and CdZnTe detectors
    Scheiber, C
    Giakos, GC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 12 - 25
  • [9] CdTe and CdZnTe detectors for timing measurements
    Okada, Y
    Takahashi, T
    Sato, C
    Watanabe, S
    Nakazawa, K
    Mori, K
    Makishima, K
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2429 - 2433
  • [10] Recent progress in CdTe and CdZnTe detectors
    Takahashi, T
    Watanabe, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 950 - 959