3D Endo: three-dimensional endodontic treatment planning

被引:0
作者
Tchorz, J. R. [1 ,2 ]
机构
[1] DPU, Abt Zahnerhaltung Parodontol & Endodontol, Krems, Austria
[2] Univ Freiburg Klinikum, Abt Zahnerhaltungskunde & Parodontol, Freiburg, Germany
关键词
cone beam computed tomography; CBCT; endodontics; 3D Endo; BEAM COMPUTED-TOMOGRAPHY; LENGTH MEASUREMENT; ACCURACY; DIAGNOSIS; TEETH;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This case report describes the three-dimensional (3D) endodontic treatment planning of a complex maxillary incisor using the 3D Endo software (Dentsply Sirona, Bensheim, Germany). Apart from a step-by-step description of the planning, the actual endodontic treatment is shown, and possible indications for the 3D Endo software are discussed.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 21 条
  • [1] Use of cone-beam computed tomography in endodontics Joint Position Statement of the American Association of Endodontists and the American Academy of Oral and Maxillofacial Radiology
    不详
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 111 (02): : 234 - 237
  • [2] Accuracy of image-guided implantology
    Brief, J
    Edinger, D
    Hassfeld, S
    Eggers, G
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) : 495 - 501
  • [3] Endodontic applications of cone-beam volumetric tomography
    Cotton, Taylor P.
    Geisler, Todd M.
    Holden, David T.
    Schwartz, Scott A.
    Schindler, William G.
    [J]. JOURNAL OF ENDODONTICS, 2007, 33 (09) : 1121 - 1132
  • [4] Digital method for quantification of circumferential periodontal bone level using cone beam CT
    Fleiner, Jonathan
    Hannig, Christian
    Schulze, Dirk
    Stricker, Andres
    Jacobs, Reinhilde
    [J]. CLINICAL ORAL INVESTIGATIONS, 2013, 17 (02) : 389 - 396
  • [5] Detection of Vertical Root Fractures in Endodontically Treated Teeth by a Cone Beam Computed Tomography Scan
    Hassan, Bassam
    Metska, Maria Elissavet
    Ozok, Ahmet Rifat
    van der Stelt, Paul
    Wesselink, Paul Rudolf
    [J]. JOURNAL OF ENDODONTICS, 2009, 35 (05) : 719 - 722
  • [6] Precision of Endodontic Working Length Measurements: A Pilot Investigation Comparing Cone-Beam Computed Tomography Scanning with Standard Measurement Techniques
    Janner, Simone F. M.
    Jeger, Franziska B.
    Lussi, Adrian
    Bornstein, Michael M.
    [J]. JOURNAL OF ENDODONTICS, 2011, 37 (08) : 1046 - 1051
  • [7] Endodontic Application of Cone-Beam Computed Tomography in South Korea
    Kim, Seonah
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (02) : 153 - 157
  • [8] Proximity of the Mandibular Canal to the Tooth Apex
    Kovisto, Tyler
    Ahmad, Mansur
    Bowles, Walter R.
    [J]. JOURNAL OF ENDODONTICS, 2011, 37 (03) : 311 - 315
  • [9] Accuracy of full guided vs. half-guided implant surgery
    Kuehl, S.
    Zuercher, S.
    Mahid, T.
    Mueller-Gerbl, M.
    Filippi, A.
    Cattin, P.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (07) : 763 - 769
  • [10] The Validity of Cone-beam Computed Tomography in Measuring Root Canal Length Using a Gold Standard
    Liang, Yu-Hong
    Jiang, Lan
    Chen, Chen
    Gao, Xue-Jun
    Wesselink, Paul R.
    Wu, Min-Kai
    Shemesh, Hagay