Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis

被引:0
|
作者
Sparacia, G [1 ]
Angileri, T [1 ]
Accardi, M [1 ]
Pappalardo, S [1 ]
Sarno, C [1 ]
DeMaria, M [1 ]
机构
[1] UNIV PALERMO,IST RADIOL P CIGNOLINI,I-90133 PALERMO,ITALY
来源
RIVISTA DI NEURORADIOLOGIA | 1997年 / 10卷
关键词
magnetic resonance imaging; spin-echo; fast spin-echo; brain; multiple sclerosis;
D O I
10.1177/19714009970100S2106
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We compared T2-weighted fast spin-echo (FSE) magnetic resonance (MR) imaging and conventional spin-echo (CSE) T2-weighted imaging in the detection of brain lesions of multiple sclerosis (MS). 20 patients with clinically definite MS underwent brain imaging with both FSE and CSE T2-weighted imaging. There was no significant difference in total number of lesions detected on FSE vs CSE (1354 vs 1378). Slightly more periventricular and subcortical lesions were detected using CSE than FSE, whereas more posterior cranial fossa lesions were detected by FSE. There was no statistically significant difference in the signal intensity (SI) ratio of MS lesions to that of surrounding normal white matter on FSE vs CSE, however the SI ratio of MS lesions was lower on FSE T2-weighted images (FSE = 1.87 +/- 0.39 vs CSE = 2.09 +/- 0.36). Considerable time savings can accrue when substituting FSE for CSE sequences in T2-weighted imaging, and this Is a compelling reason to employ such sequence in clinical practice. Our results suggest that although CSE sequences are required to confirm the diagnosis of brain involvement of MS lesions, T2-weighted FSE sequences can replace CSE sequences in long term monitoring especially when patient's movements preclude useful investigation and when optional scanning planes are required.
引用
收藏
页码:233 / 235
页数:3
相关论文
共 50 条
  • [21] FAST SPIN-ECHO INVERSION-RECOVERY IMAGING VERSUS FAST T2-WEIGHTED SPIN-ECHO IMAGING IN BONE-MARROW ABNORMALITIES
    HILFIKER, P
    ZANETTI, M
    DEBATIN, JF
    MCKINNON, G
    HODLER, J
    INVESTIGATIVE RADIOLOGY, 1995, 30 (02) : 110 - 114
  • [22] Comparing lesion detection of infratentorial multiple sclerosis lesions between T2-weighted spin-echo, 2D-FLAIR, and 3D-FLAIR sequences
    Wang, Kevin Y.
    Uribe, Tomas A.
    Lincoln, Christie M.
    CLINICAL IMAGING, 2018, 51 : 229 - 234
  • [23] Multiple Sclerosis: Comparison of the Conventional Spin-Echo T2-Weighted and Flair Techniques Through Image Processing
    Simao, Ricardo Silva
    de Azevedo Alves, Rafaela Ferreira
    Matos da Silva Boschi, Silvia Regina
    Scardovelli, Terigi Augusto
    Martini Rodrigues, Silvia Cristina
    Bianchi, Cesario
    da Silva, Alessandro Pereira
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (03) : 425 - 430
  • [24] TRUE PROTON DENSITY AND T2-WEIGHTED TURBO SPIN-ECHO SEQUENCES FOR ROUTINE MRI OF THE BRAIN
    FELLNER, F
    SCHMITT, R
    TRENKLER, J
    FELLNER, C
    HELMBERGER, T
    OBLETTER, N
    BOHMJURKOVIC, H
    NEURORADIOLOGY, 1994, 36 (08) : 591 - 597
  • [25] Fast flair imaging of the brain using the fast spin-echo and gradient spin-echo technique
    Hittmair, K
    Umek, W
    Schindler, EG
    BaSsalamah, A
    Pretterklieber, ML
    Herold, CJ
    MAGNETIC RESONANCE IMAGING, 1997, 15 (04) : 405 - 414
  • [26] A prospective comparison of brain contrast characteristics and lesion detection using single-shot fast spin-echo and fast spin-echo
    Mittal, TK
    Halpin, SFS
    Bourne, MW
    Hourihan, MD
    Perkins, T
    Sun, Y
    Tan, S
    NEURORADIOLOGY, 1999, 41 (07) : 480 - 486
  • [27] MRI of acute cerebral infarction: A comparison of FLAIR and T2-weighted fast spin-echo imaging
    Noguchi, K
    Ogawa, T
    Inugami, A
    Fujita, H
    Hatazawa, J
    Shimosegawa, E
    Okudera, T
    Uemura, K
    Seto, H
    NEURORADIOLOGY, 1997, 39 (06) : 406 - 410
  • [28] BRAIN HEMORRHAGE - EVALUATION WITH FAST SPIN-ECHO AND CONVENTIONAL DUAL SPIN-ECHO IMAGES
    JONES, KM
    MULKERN, RV
    MANTELLO, MT
    MELKI, PS
    AHN, SS
    BARNES, PD
    JOLESZ, FA
    RADIOLOGY, 1992, 182 (01) : 53 - 58
  • [29] Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI
    Aymerich, F. X.
    Auger, C.
    Alcaide-Leon, P.
    Pareto, D.
    Huerga, E.
    Corral, J. F.
    Mitjana, R.
    Sastre-Garriga, J.
    Montalban, X.
    Rovira, A.
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1361 - 1368
  • [30] MR Imaging of the Spine at 3.0T with T2-Weighted IDEAL Fast Recovery Fast Spin-Echo Technique
    Ren, Ai-Jun
    Guo, Yong
    Tian, Shu-Ping
    Shi, Li-Jing
    Huang, Min-Hua
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (01) : 44 - 52