Reliability of the Minto model for target-controlled infusion of remifentanil during cardiac surgery with cardiopulmonary bypass

被引:5
作者
Scherrer, Vincent [1 ]
Lamoureux, Fabien [2 ,3 ]
Chaventre, Celine [1 ]
Thill, Caroline [4 ]
Demailly, Zoe [1 ,3 ]
Selim, Jean [1 ,3 ]
Bauer, Fabrice [3 ,5 ]
Imbert, Laurent [2 ]
Wurtz, Veronique [1 ]
Compere, Vincent [1 ,6 ]
Clavier, Thomas [1 ,3 ]
Besnier, Emmanuel [1 ,3 ]
机构
[1] Rouen Univ Hosp, Dept Anaesthesiol & Crit Care, Rouen, France
[2] Rouen Univ Hosp, Dept Pharmacol, Rouen, France
[3] Normandie Univ, EnVi, Inserm U1096, UNIROUEN, Rouen, France
[4] Rouen Univ Hosp, Dept Biostat, Rouen, France
[5] Rouen Univ Hosp, Dept Cardiac Surg, Rouen, France
[6] Normandie Univ, INSERM U1239, UNIROUEN, Rouen, France
关键词
cardiac surgery; cardiopulmonary bypass; pharmacokinetic; remifentanil; target-controlled infusion; COMPUTER-CONTROLLED INFUSION; PREDICTIVE PERFORMANCE; BISPECTRAL INDEX; PROPOFOL; PHARMACOKINETICS; PLASMA; ANESTHESIA; METAANALYSIS; SUFENTANIL; BLOOD;
D O I
10.1016/j.bja.2022.05.003
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The Minto pharmacokinetic model is used for target-controlled infusion of remifentanil. The reliability of this model has never been evaluated during normothermic cardiac surgery with cardiopulmonary bypass (CPB). The aim of this study was to assess the predictive performance of the model during CPB to determine its reliability during cardiac surgery. Methods: This was a single-centre observational study. Arterial blood samples were drawn at five time points: T1, after tracheal intubation; T2, immediately before CPB; T3, 10 min after starting CPB; T4, 45 min after starting CPB; T5, 10 min after weaning off CPB. Prediction error (PE) and absolute prediction error (APE) were calculated for each sample and used to determine median prediction error (MDPE) and median absolute prediction error (MDAPE) per patient. Risk factors for APE >30% were assessed using multivariable analysis. Results are presented as medians with inter-quartile ranges. Results: Fifty-eight patients with 283 blood samples (110 during CPB) were included. In the pre-CPB period, MDPE and MDAPE were e17.3 [-32.9 to 2.3] and 24.6 [12-37.7]%, whereas during CPB, they were e1.8 [-15.6 to 11.1] and 14.0 [6.74-27.1]%, respectively. There was no statistically significant difference between measured and predicted remifentanil plasma concentrations during CPB. Age, preoperative albumin concentrations, temperature, and haemodilution were not independently associated with MDAPE >30%. Conclusions: The Minto model accurately predicts plasma remifentanil concentrations during cardiac surgery with CPB.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 35 条
[21]  
OKUTANI R, 1988, ANESTH ANALG, V67, P667
[22]   Target-controlled infusion of propofol and remifentanil in cardiac anaesthesia:: influence of age on predicted effect-site concentrations [J].
Ouattara, A ;
Boccara, G ;
Lemaire, S ;
Köckler, U ;
Landi, M ;
Vaissier, E ;
Léger, P ;
Coriat, P .
BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (05) :617-622
[23]   2017 EACTS/EACTA Guidelines on patient blood management for adult cardiac surgery The Task Force on Patient Blood Management for Adult Cardiac Surgery of the European Association for Cardio-Thoracic Surgery (EACTS) and the European Association of Cardiothoracic Anaesthesiology (EACTA) [J].
Pagano, Domenico ;
Milojevic, Milan ;
Meesters, Michael I. ;
Benedetto, Umberto ;
Bolliger, Daniel ' ;
von Heymann, Christian ;
Jeppsson, Anders ;
Koster, Andreas ;
Osnabrugge, Ruben L. ;
Ranucci, Marco ;
Ravn, Hanne Berg ;
Vonk, Alexander B. A. ;
Wahba, Alexander ;
Boer, Christa .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (01) :79-111
[24]  
Piacevoli Q, 2015, MINERVA ANESTESIOL, V81, P305
[25]  
Rees K, 2001, Cochrane Database Syst Rev
[26]  
Rosner B., 2011, FUNDAMENTALS BIOSTAT
[27]   Effect of temperature and cardiopulmonary bypass on the pharmacokinetics of remifentanil [J].
Russell, D ;
Royston, D ;
Rees, PH ;
Gupta, SK ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 79 (04) :456-459
[28]   Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis [J].
Sanders, M. ;
Servaas, S. ;
Slagt, C. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (03) :433-460
[29]   The Safety of Target-Controlled Infusions [J].
Schnider, Thomas W. ;
Minto, Charles F. ;
Struys, Michel M. R. F. ;
Absalom, Anthony R. .
ANESTHESIA AND ANALGESIA, 2016, 122 (01) :79-85
[30]  
Schuttler J, 1988, Anaesthesia, V43 Suppl, P2, DOI 10.1111/j.1365-2044.1988.tb09059.x