Diagnostic accuracy of the Retinal Thickness Analyser: differentiation between normal eyes and eyes with glaucoma or macular pathologies

被引:4
作者
Maier, Philip [1 ]
Funk, Jens [1 ]
机构
[1] Univ Eye Hosp Freiburg, D-79106 Freiburg, Germany
关键词
macula; glaucoma; ophthalmologic diagnostic techniques; retinal thickness analyser;
D O I
10.1007/s00417-006-0288-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The Retinal Thickness Analyser (RTA) is intended to detect glaucomatous changes as well as macular pathologies at the posterior pole. We determined the diagnostic accuracy for eyes with manifest glaucoma or macular diseases. Methods: We examined 71 eyes with long-term, established eye conditions. Included were 28 eyes with glaucoma, 21 with different macular diseases and 22 normal eyes. All examinations were evaluated in a blind-test by RTA experts without any clinical information on the patients. After comparison of the RTA interpretation with the clinical diagnosis, we determined sensitivity, specificity, positive and negative predictive values. Results: Of 71 examinations, 15 (21%) were not interpretable. If these results are excluded, the following diagnostic accuracy values were calculated for glaucoma and macular disorders respectively: sensitivity 75 and 59%, specificity 55 and 97%, positive predictive value 48 and 90% and negative predictive value 80 and 84%. These values were not significantly different when both eyes of each patient were included in the final analysis (n=133). Conclusion: The diagnostic values of the RTA determined in this case control study were not satisfactory. However, no clinical information was used in the assessment. The extent to which additional clinical information increases the diagnostic value remains to be determined.
引用
收藏
页码:1113 / 1118
页数:6
相关论文
共 50 条
  • [21] Diagnostic ability of OCT parameters and retinal ganglion cells count in identification of glaucoma in myopic preperimetric eyes
    Rolle, Teresa
    Bonetti, Beatrice
    Mazzucco, Alberto
    Dallorto, Laura
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [22] Sensitivity and specificity for detecting early glaucoma in eyes with high myopia from normative database of macular ganglion cell complex thickness obtained from normal non-myopic or highly myopic Asian eyes
    Nakanishi, Hideo
    Akagi, Tadamichi
    Hangai, Masanori
    Kimura, Yugo
    Suda, Kenji
    Kumagai, Kyoko Kawashima
    Morooka, Satoshi
    Ikeda, Hanako Ohashi
    Yoshimura, Nagahisa
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (07) : 1143 - 1152
  • [23] Relationship between ocular risk factors for glaucoma and optic disc rim in normal eyes
    Iwase, Aiko
    Sawaguchi, Shoichi
    Tanaka, Kenji
    Tsutsumi, Tae
    Araie, Makoto
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (08) : 1120 - 1124
  • [24] Rigidity of Retinal Vessel in Untreated Eyes of Normal Tension Primary Open-angle Glaucoma Patients
    Oettli, Alexander
    Gugleta, Konstantin
    Kochkorov, Asan
    Katamay, Robert
    Flammer, Josef
    Orgul, Selim
    JOURNAL OF GLAUCOMA, 2011, 20 (05) : 303 - 306
  • [25] Use of the GDx to detect differences in retinal nerve fibre layer thickness between normal, ocular hypertensive and early glaucomatous eyes
    Kamal, DS
    Bunce, C
    Hitchings, RA
    EYE, 2000, 14 (3) : 367 - 370
  • [26] Use of the GDx to detect differences in retinal nerve fibre layer thickness between normal, ocular hypertensive and early glaucomatous eyes
    D S Kamal
    C Bunce
    R A Hitchings
    Eye, 2000, 14 : 367 - 370
  • [27] Relationship Between Deep Retinal Macular Vessel Density and Bipolar Cell Function in Glaucomatous Eyes
    Yoshikawa, Yuji
    Shoji, Takuhei
    Kanno, Junji
    Ishii, Hirokazu
    Chino, Minami
    Igawa, Yuro
    Shinoda, Kei
    Miyake, Yozo
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (10):
  • [28] OPTICAL COHERENCE TOMOGRAPHY EVIDENCE ON THE CORRELATION OF CHOROIDAL THICKNESS AND AGE WITH VASCULARIZED RETINAL LAYERS IN NORMAL EYES
    Abdolrahimzadeh, Solmaz
    Parisi, Francesco
    Scavella, Vittorio
    Recupero, Santi M.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (12): : 2329 - 2338
  • [29] Retinal Nerve Fibre Layer Thickness Increases with Decreasing Spectralis OCT Signal Strength in Normal Eyes
    Strampe, Margaret R.
    Eldweik, Luai
    Chaon, Benjamin C.
    Maki, Sarah
    Wieland, Tyler
    Satija, Celine
    McClelland, Collin
    Lee, Michael S.
    NEURO-OPHTHALMOLOGY, 2020, 44 (02) : 100 - 103
  • [30] Macular Retinal Ganglion Cell Complex Damage in the Apparently Normal Visual Field of Glaucomatous Eyes With Hemifield Defects
    Takagi, Seiji T.
    Kita, Yoshiyuki
    Yagi, Fumihiko
    Tomita, Goji
    JOURNAL OF GLAUCOMA, 2012, 21 (05) : 318 - 325