Ultrasound 3D volume reconstruction from an optically tracked endorectal ultrasound (TERUS) probe

被引:2
|
作者
Warmath, JR [1 ]
Bao, P [1 ]
Herline, AJ [1 ]
Galloway, RL [1 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37240 USA
来源
MEDICAL IMAGING 2004: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY | 2004年 / 5367卷
关键词
image-guided procedures; 3-D utrasound; endorectal utrasound; freehand ultrasound; rectal cancer;
D O I
10.1117/12.535306
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Endorectal Utrasound (ERUS) is essential for the accurate staging of rectal cancer. Staging is important to the treatment of patients with rectal cancer because it will determine whether the patient receives preoperative radiotherapy for the purpose of tumor downstaging. ERUS images are intrinsically different from images taken by Computed Tomography (CT) or Magnetic Resonance Imaging (MRI) in that ultrasound provides 2D images while CT and MRI provide 3D data sets that can be rendered into volumes and then re-sliced and viewed as 2D images in any desired orientation. This fundamental difference between ultrasound and tomographic imaging modalities creates a problem when a direct comparison between ultrasound and CT or MRI is desired. To accomplish the goal of following tumor volume over time, an accurate ultrasound volume must be constructed. By optically tracking the ERUS probe as data is collected, the intensity value for each pixel is saved and then inserted into the nearest voxel in the ERUS volume matrix. We validate the accuracy of volume reconstruction by finding the 3D coordinates of targets that are inside of the ERUS volume and comparing them to their known physical locations.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 32 条
  • [21] 3D Quasi-Static Ultrasound Elastography With Plane Wave In Vivo
    Papadacci, Clement
    Bunting, Ethan A.
    Konofagou, Elisa E.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (02) : 357 - 365
  • [22] Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
    Diego D. B. Carvalho
    Stefan Klein
    Zeynettin Akkus
    Gerrit L. ten Kate
    Arend F. L. Schinkel
    Johan G. Bosch
    Aad van der Lugt
    Wiro J. Niessen
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 207 - 215
  • [23] Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
    Carvalho, Diego D. B.
    Klein, Stefan
    Akkus, Zeynettin
    ten Kate, Gerrit L.
    Schinkel, Arend F. L.
    Bosch, Johan G.
    van der Lugt, Aad
    Niessen, Wiro J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 207 - 215
  • [24] A FAST SLAM APPROACH TO FREEHAND 3-D ULTRASOUND RECONSTRUCTION FOR CATHETER ABLATION GUIDANCE IN THE LEFT ATRIUM
    Koolwal, Aditya B.
    Barbagli, Federico
    Carlson, Christopher R.
    Liang, David H.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (12) : 2037 - 2054
  • [25] Intensity-based registration of freehand 3D ultrasound and CT-scan images of the kidney
    Antoine Leroy
    Pierre Mozer
    Yohan Payan
    Jocelyne Troccaz
    International Journal of Computer Assisted Radiology and Surgery, 2007, 2 : 31 - 41
  • [26] Optimal configurations of an electromagnetic tracking system for 3D ultrasound imaging of pediatric hips - A phantom study
    Pham, Thanh-Tu
    Le, Lawrence H.
    Andersen, John
    Lou, Edmond H.
    MEDICAL ENGINEERING & PHYSICS, 2024, 131
  • [27] Intensity-based registration of freehand 3D ultrasound and CT-scan images of the kidney
    Leroy, Antoine
    Mozer, Pierre
    Payan, Yohan
    Troccaz, Jocelyne
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 (01) : 31 - 41
  • [28] Solving for Free-hand and Real-Time 3D Ultrasound Calibration with Anisotropic Orthogonal Procrustes Analysis
    Chen, Elvis C. S.
    McLeod, A. Jonathan
    Jayarathne, Uditha L.
    Peters, Terry M.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [29] A semiautomatic method for in vivo three-dimensional quantitative analysis of fascial layers mobility based on 3D ultrasound scans
    Condino, S.
    Turini, G.
    Parrini, S.
    Stecco, A.
    Busoni, F.
    Ferrari, V.
    Ferrari, M.
    Gesi, M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (11) : 1721 - 1735
  • [30] A freehand 3D ultrasound imaging system using open-source software tools with improved edge-preserving interpolation
    Daoud, Mohammad I.
    Alshalalfah, Abdel-Latif
    Awwad, Falah
    Al-Najar, Mahasen
    International Journal of Open Source Software and Processes, 2014, 5 (03) : 39 - 57