Bubble characteristics measured using a monofibre optical probe in a bubble column and freeboard region under high gas holdup conditions

被引:55
|
作者
Pjontek, Dominic [1 ]
Parisien, Valois [1 ]
Macchi, Arturo [1 ]
机构
[1] Univ Ottawa, Ctr Catalysis Res & Innovat, Dept Chem & Biol Engn, Ottawa, ON K1N 6N5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Bubble properties; Optical probe; Bubble column; Gas holdup; High pressure; Surfactant; FLUIDIZED-BED; VOID FRACTION; LOCAL MEASUREMENTS; ELEVATED PRESSURE; FIBER PROBE; LIQUID; VELOCITY; DYNAMICS; SINGLE; SIZE;
D O I
10.1016/j.ces.2014.02.024
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Local bubble characteristics, including gas holdups, bubble rise velocities, and chord lengths, were measured using a monolibre optical probe manufactured to withstand elevated pressures. Previous studies have validated the use of single tip probes for simultaneous measurement of local bubble properties at atmospheric conditions; however no study has been currently reported for these probes at elevated pressures. Experiments were conducted in a 101.6 mm diameter column operating at pressures up to 9.0 MPa. Surfactant addition and operating pressure were studied to simulate high gas holdups observed in many industrial reactors containing liquid mixtures with surface-active compounds. Experiments were hence completed using two liquid phases: tap water and a 0.5 wt% aqueous ethanol solution. Liquid and gas superficial velocities were varied between 0-90 mm/s and 0-150 mm/s, respectively. Radial profiles at atmospheric conditions validated the probe measurements in water. Local holdups, rise velocities and chord lengths were adequately measured in water up to 9.0 MPa. The probe struggled in the aqueous ethanol solution due to its physical constraints (i.e., Lip diameter and sensing length) when compared to the significant bubble size reduction (chord lengths below 0.5 mm). Comparisons with fluidized bed freeboard measurements demonstrated that flow through the bed enhanced bubble breakup for a coalescing system, but had a negligible impact with the added surfactant. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:153 / 169
页数:17
相关论文
共 46 条
  • [1] Bubble swarm characteristics in a bubble column under high gas holdup conditions
    Parisien, Valois
    Farrell, Alixia
    Pjontek, Dominic
    McKnight, Craig A.
    Wiens, Jason
    Macchi, Arturo
    CHEMICAL ENGINEERING SCIENCE, 2017, 157 : 88 - 98
  • [2] Gas holdup at dynamic equilibrium region of a bubble column: Effect of bubble generator performance
    Gong, Chun-Kai
    Xu, Xiao
    Yang, Qiang
    CHEMICAL ENGINEERING JOURNAL, 2022, 443
  • [3] Studies on gas holdup in a bubble column using porous spargers with additives
    Jha, Abhishek
    Mohan, B. Raj
    Chakraborty, S.
    Meikap, B. C.
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2008, 3 (04) : 417 - 424
  • [4] Effect of L/D Ratio on Phase Holdup and Bubble Dynamics in Slurry Bubble Column using Optical Fiber Probe Measurements
    Gheni, Saba A.
    Abdulaziz, Yasser I.
    Al-Dahhan, Muthanna H.
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2016, 14 (02) : 653 - 664
  • [5] Measurement method of bubble behavior by optical probe in gas-liquid bubble column reactor
    He G.
    Guo X.
    Yang S.
    Jin H.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2017, 43 (02): : 253 - 259
  • [6] Study on gas holdup characteristics of micro-bubble countercurrent contacting flotation column
    Han, Jikang
    Wang, Weizhi
    Li, Ran
    PHYSICOCHEMICAL PROBLEMS OF MINERAL PROCESSING, 2020, 56 (04): : 665 - 675
  • [7] Gas holdup and liquid axial dispersion under slug flow conditions in gas-liquid bubble column
    Shawaqfeh, AT
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2003, 42 (10) : 767 - 775
  • [8] Measurement of gas phase characteristics using a monofibre optical probe in a three-phase flow
    Mena, P. C.
    Rocha, F. A.
    Teixeira, J. A.
    Sechet, P.
    Cartellier, A.
    CHEMICAL ENGINEERING SCIENCE, 2008, 63 (16) : 4100 - 4115
  • [9] Experimental study of temperature effects on bubble characteristics and gas holdup in electroflotation column
    Issaoui, Radhia
    Ben Mansour, Lassaad
    DESALINATION AND WATER TREATMENT, 2019, 162 : 186 - 192
  • [10] On the reliability of an optical fibre probe in bubble column under industrial relevant operating conditions
    Chaumat, H.
    Billet-Duquenne, A. M.
    Augier, F.
    Mathieu, C.
    Delmas, H.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 31 (06) : 495 - 504