Newly Developed System for the Robust Detection of Listeria monocytogenes Based on a Bioelectric Cell Biosensor

被引:11
作者
Hadjilouka, Agni [1 ,2 ]
Loizou, Konstantinos [1 ]
Apostolou, Theofylaktos [1 ]
Dougiakis, Lazaros [1 ]
Inglezakis, Antonios [1 ]
Tsaltas, Dimitrios [2 ]
机构
[1] EMBIO Diagnost Ltd, Athalassas Ave 8, CY-2018 Nicosia, Cyprus
[2] Cyprus Univ Technol, Dept Agr Sci Biotechnol & Food Sci, 30 Archbishop Kyprianos, CY-3036 Limassol, Cyprus
来源
BIOSENSORS-BASEL | 2020年 / 10卷 / 11期
关键词
Listeria monocytogenes; cell-based biosensor; bioelectric recognition assay; membrane-engineering; VIRUS-SPECIFIC ANTIBODIES; EFFICIENT SEPARATION; SENSITIVE DETECTION; FIBROBLAST CELLS; RAPID DETECTION; MEMBRANE; PATHOGENS; SENSORS; MILK;
D O I
10.3390/bios10110178
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Human food-borne diseases caused by pathogenic bacteria have been significantly increased in the last few decades causing numerous deaths worldwide. The standard analyses used for their detection have significant limitations regarding cost, special facilities and equipment, highly trained staff, and a long procedural time that can be crucial for foodborne pathogens with high hospitalization and mortality rates, such as Listeria monocytogenes. This study aimed to develop a biosensor that could detect L. monocytogenes rapidly and robustly. For this purpose, a cell-based biosensor technology based on the Bioelectric Recognition Assay (BERA) and a portable device developed by EMBIO Diagnostics, called B.EL.D (Bio Electric Diagnostics), were used. Membrane engineering was performed by electroinsertion of Listeria monocytogenes homologous antibodies into the membrane of African green monkey kidney (Vero) cells. The newly developed biosensor was able to detect the pathogen's presence rapidly (3 min) at concentrations as low as 10(2) CFU mL(-1), demonstrating a higher sensitivity than most existing biosensor-based methods. In addition, lack of cross-reactivity with other Listeria species, as well as with Escherichia coli, was shown, thus, indicating biosensor's significant specificity against L. monocytogenes.
引用
收藏
页数:13
相关论文
共 39 条
[1]   Disposable all-printed electronic biosensor for instantaneous detection and classification of pathogens [J].
Ali, Shawkat ;
Hassan, Arshad ;
Hassan, Gul ;
Eun, Chang-Ho ;
Bae, Jinho ;
Lee, Chong Hyun ;
Kim, In-Jung .
SCIENTIFIC REPORTS, 2018, 8
[2]  
[Anonymous], 2020, Listeria (listeriosis)
[3]  
[Anonymous], 2017, ISO 11290-2
[4]   Newly Developed System for Acetamiprid Residue Screening in the Lettuce Samples Based on a Bioelectric Cell Biosensor [J].
Apostolou, Theofylaktos ;
Loizou, Konstantinos ;
Hadjilouka, Agni ;
Inglezakis, Antonios ;
Kintzios, Spyridon .
BIOSENSORS-BASEL, 2020, 10 (02)
[5]   Recent Developments in Enzyme, DNA and Immuno-Based Biosensors [J].
Asal, Melis ;
Ozen, Ozlem ;
Sahinler, Mert ;
Polatoglu, Ilker .
SENSORS, 2018, 18 (06)
[6]   A novel and simple cell-based detection system with a collagen-encapsulated B-lymphocyte cell line as a biosensor for rapid detection of pathogens and toxins [J].
Banerjee, Pratik ;
Lenz, Dominik ;
Robinson, Joseph Paul ;
Rickus, Jenna L. ;
Bhunia, Arun K. .
LABORATORY INVESTIGATION, 2008, 88 (02) :196-206
[7]   Cell-based biosensor for rapid screening of pathogens and toxins [J].
Banerjee, Pratik ;
Bhunia, Arun K. .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :99-106
[8]   The Microbiologist's Guide to Membrane Potential Dynamics [J].
Benarroch, Jonatan M. ;
Asally, Munehiro .
TRENDS IN MICROBIOLOGY, 2020, 28 (04) :304-314
[9]   Introduction to biosensors [J].
Bhalla, Nikhil ;
Jolly, Pawan ;
Formisano, Nello ;
Estrela, Pedro .
BIOSENSOR TECHNOLOGIES FOR DETECTION OF BIOMOLECULES, 2016, 60 (01) :1-8
[10]   Rapid detection of Listeria monocytogenes in milk by self-assembled electrochemical immunosensor [J].
Cheng, Chaonan ;
Peng, Yuan ;
Bai, Jialei ;
Zhang, Xiaoyan ;
Liu, Yuanyuan ;
Fan, Xianjun ;
Ning, Baoan ;
Gao, Zhixian .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 :900-906