A new fault ride-through control for DFIG-based wind energy systems

被引:55
作者
Morshed, Mohammad Javad [1 ]
Fekih, Afef [1 ]
机构
[1] Univ Louisiana Lafayette, Dept Elect & Comp Engn, Lafayette, LA 70504 USA
关键词
Sliding mode control; Second order integral terminal; Wind turbine; Fuzzy control; Voltage sag; SLIDING-MODE; COMPENSATION; STRATEGY; DESIGN;
D O I
10.1016/j.epsr.2017.02.010
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with the design and analysis of a fault ride-through control (FRTC) scheme for a DFIG-based wind turbine. A new Fuzzy Second Order Integral Terminal Sliding Mode Control (FSOITSMC) is designed for the rotor and grid-side converters. The design is further augmented by a series grid side converter (SGSC) in order to avoid DFIG's disconnection from the grid during faulty conditions. The proposed control paradigm was implemented on a DFIG-based wind turbine. Its performance was assessed using DFIG's realistic modes of operation such as normal, sub- and super-synchronous modes. Both symmetrical arid unsymmetrical faults were considered to further evaluate the performance of the proposed approach. Simulation results proved the ability of the proposed FRTC scheme in effectively controlling DFIG-based wind turbines under various operating conditions. Despite subjecting the DFIG to various modes of operations and extreme faulty conditions, the over currents of the rotor and stator did not exceed 10%, which is a very good performance compared to existing approaches. The proposed approach was able to maintain the DFIG's currents and voltages within acceptable ranges, hence preventing damages to the converters during various faulty conditions. Endowing the DFIG with superior ride through capabilities and ensuring its continuous connectivity to the grid even under non ideal grid voltage conditions are among the positive features of the proposed approach. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 269
页数:12
相关论文
共 38 条
[1]   Series Voltage Compensation for DFIG Wind Turbine Low-Voltage Ride-Through Solution [J].
Abdel-Baqi, Omar ;
Nasiri, Adel .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) :272-280
[2]  
Ambati B.B., 2015, IEEE T ENERGY CONVER, V30, P1
[3]  
[Anonymous], IEEE T AUTOM CONTROL
[4]   Four-phase interleaved DC/DC boost converter interfaces for super-capacitors in electric vehicle application based onadvanced sliding mode control design [J].
Ayoubi, Y. ;
Elsied, M. ;
Oukaour, A. ;
Chaoui, H. ;
Slamani, Y. ;
Gualous, H. .
ELECTRIC POWER SYSTEMS RESEARCH, 2016, 134 :186-196
[5]  
Bartolini G., 2008, MODEM SLIDING MODE C
[6]   Second-Order Sliding Mode Control of a Doubly Fed Induction Generator Driven Wind Turbine [J].
Beltran, Brice ;
Benbouzid, Mohamed El Hachemi ;
Ahmed-Ali, Tarek .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (02) :261-269
[7]   Analysis of chattering in continuous sliding-mode controllers [J].
Boiko, I ;
Fridman, L .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2005, 50 (09) :1442-1446
[8]   Digital-signal-processor-based DC/AC inverter with integral-compensation terminal sliding-mode control [J].
Chang, F. -J. ;
Chang, E. -C. ;
Liang, T. -J. ;
Chen, J. -F. .
IET POWER ELECTRONICS, 2011, 4 (01) :159-167
[9]   A new approach for low voltage ride through capability in DFIG based wind farm [J].
Dosoglu, M. Kenan .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 83 :251-258
[10]  
EirGrid plc, 2011, EIRGRID GRID COD VER