Internal Fixation of the Distal Humerus: A Comprehensive Biomechanical Study Evaluating Current Fixation Techniques

被引:30
作者
Caravaggi, Paolo [1 ]
Laratta, Joseph L. [1 ]
Yoon, Richard S. [2 ]
De Biasio, Justin [3 ]
Ingargiola, Michael [1 ]
Frank, Matthew A. [1 ]
Capo, John T. [2 ]
Liporace, Frank A. [2 ]
机构
[1] Rutgers New Jersey Med Sch, Dept Orthopaed Surg, Div Orthopaed Trauma, Newark, NJ USA
[2] NYU Hosp Joint Dis, Div Orthopaed Trauma, Dept Orthopaed Surg, New York, NY 10003 USA
[3] Mt Sinai Sch Med, New York, NY USA
关键词
orthogonal; stiffness; distal humerus; parallel; fatigue; BICONDYLAR INTRAARTICULAR FRACTURES; CONVENTIONAL RECONSTRUCTION PLATES; PLATING SYSTEMS; ELBOW; PARALLEL; CADAVER;
D O I
10.1097/BOT.0b013e3182a6693f
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: The purpose of this study was to evaluate current fixation techniques in the operative fixation of distal humerus fractures, both with conventional and locked plating in both parallel and orthogonal orientation. Methods: Twenty-eight upper extremities from 14 cadavers were prepared to create 4 implant testing constructs: Synthes locking plates (IMP1) (medial and posterolateral with lateral flange), Acumed parallel locking plates (IMP2), Smith & Nephew orthogonal locking plates (IMP3), and Synthes orthogonal 3.5-reconstruction plating (IMP4) (1 posterolateral and 1 medial). A 5-mm supracondylar osteotomy was made to simulate the fracture. Stiffness in axial and sagittal plane loading, fatigue properties (over 5000 cycles), and ultimate strength were determined for each construct by biomechanical testing. Results: The parallel locking plates (IMP2) exhibited the highest stiffness in axial load and the highest ultimate strength (P < 0.05). No significant differences in sagittal plane stiffness and in the fatigue properties were seen across the locking plate groups, regardless of orientation. Locked plating constructs performed significantly better in all categories when compared with conventional nonlocked plating. Plastic deformation and implant loosening were the main modes of failure after ultimate strength test. Conclusion: Parallel locking plate configuration showed significantly higher stiffness to axial load and ultimate failure strength when compared with orthogonal locked and nonlocked plating. Locked plating configurations performed significantly better than nonlocked plating configurations, regardless of orientation. Although parallel orientation seems biomechanically superior, translation to the clinical setting may prove difficult when taking surrounding soft tissue and exposure into consideration.
引用
收藏
页码:222 / 226
页数:5
相关论文
共 24 条
[1]   NON-UNION OF FRACTURES OF THE DISTAL END OF THE HUMERUS [J].
ACKERMAN, G ;
JUPITER, JB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :75-83
[2]   A biomechanical comparison of plate configuration in distal humerus fractures [J].
Arnander, Magnus W. T. ;
Reeves, Alexander ;
MacLeod, Iain A. R. ;
Pinto, Thomas M. ;
Khaleel, Arshad .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (05) :332-336
[3]  
Haas N, 2001, Injury, V32 Suppl 2, pB51
[4]  
Helfet D L, 1990, J Orthop Trauma, V4, P260, DOI 10.1097/00005131-199004030-00004
[5]  
HELFET DL, 1993, CLIN ORTHOP RELAT R, P26
[6]  
Henley M B, 1987, J Orthop Trauma, V1, P24, DOI 10.1097/00005131-198701010-00004
[7]   FRACTURES OF THE ADULT DISTAL HUMERUS - ELBOW FUNCTION AFTER INTERNAL-FIXATION [J].
HOLDSWORTH, BJ ;
MOSSAD, MM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (03) :362-365
[8]  
Jacobson S R, 1997, J South Orthop Assoc, V6, P241
[9]   INTERCONDYLAR FRACTURES OF THE HUMERUS - AN OPERATIVE APPROACH [J].
JUPITER, JB ;
NEFF, U ;
HOLZACH, P ;
ALLGOWER, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (02) :226-239
[10]   Are conventional reconstruction plates equivalent to precontoured locking plates for distal humerus fracture fixation? A biomechanics cadaver study [J].
Koonce, Ryan C. ;
Baldini, Todd H. ;
Morgan, Steven J. .
CLINICAL BIOMECHANICS, 2012, 27 (07) :697-701