Energy efficiency using the simulation software of atrium thermal environment in residential building: a case study

被引:7
作者
Amani, Nima [1 ]
机构
[1] Islamic Azad Univ, Dept Civil Engn, Chalous Branch, Chalous, Iran
关键词
Atrium; residential building; energy efficiency; comparative analysis; ECOTECT; PERFORMANCE; DESIGN; CLIMATE; ECOTECT; SYSTEMS; SPACES;
D O I
10.1080/17512549.2017.1354781
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study evaluates the energy consumption of atria in hot and dry climate zones. The author used a research tool for simulation, ECOTECT software, and assigned regional climate conditions as a starting point. Then, the energy consumption was analysed by choosing a suitable atrium for energy efficiency in residential buildings. The analysis software of ECOTECT can provide a scientific basis for energy-saving planning of the buildings. To understand the optimization of residential building planning, factors such as hourly solar exposure, fabric gains, and energy distribution in building were analysed. This research in hot and dry climate was designed to use the optimum atrium in building for energy saving in warm seasons. According to an analysis performed using ECOTECT, it was revealed that the optimum atrium in building to keep in hot and dry climate is the four-side atrium with total radiation incident of 2,506,027 W, radiation absorption of 902,795 W, and radiation transmission of 297,118 W in hot summer. The results of this research are useful for energy efficiency of buildings and producing a comfortable living environment in future.
引用
收藏
页码:65 / 79
页数:15
相关论文
共 36 条
[1]   Design and low energy ventilation solutions for atria in the tropics [J].
Abdullah, Abd Halid ;
Wang, Fan .
SUSTAINABLE CITIES AND SOCIETY, 2012, 2 (01) :8-28
[2]   Field study on indoor thermal environment in an atrium in tropical climates [J].
Abdullah, Abd. Halid ;
Meng, Qinglin ;
Zhao, Lihua ;
Wang, Fan .
BUILDING AND ENVIRONMENT, 2009, 44 (02) :431-436
[3]   Comparative analysis of energy performance between courtyard and atrium in buildings [J].
Aldawoud, Abdelsalam ;
Clark, Ray .
ENERGY AND BUILDINGS, 2008, 40 (03) :209-214
[4]   The influence of the atrium geometry on the building energy performance [J].
Aldawoud, Abdelsalam .
ENERGY AND BUILDINGS, 2013, 57 :1-5
[5]  
[Anonymous], 2016, KERMAN CLIMATE TEMPE
[6]  
[Anonymous], ENERGY EFFICIENT BUI
[7]   Analytical model of atrium for heating and ventilating an institutional building naturally [J].
Assadi, M. Khalaji ;
Dalir, F. ;
Hamidi, A. A. .
ENERGY AND BUILDINGS, 2011, 43 (10) :2595-2601
[8]   Energy performance of daylight-linked automatic lighting control systems in large atrium spaces: report on two field-monitored case studies [J].
Atif, MR ;
Galasiu, AD .
ENERGY AND BUILDINGS, 2003, 35 (05) :441-461
[9]   Day lighting in an atrium-type high performance house [J].
Berardi, Umberto ;
Wang, Taoning .
BUILDING AND ENVIRONMENT, 2014, 76 :92-104
[10]   Experimental and simulation study on the performance of daylighting in an industrial building and its energy saving potential [J].
Chen, Yuanyi ;
Liu, Junjie ;
Pei, Jingjing ;
Cao, Xiaodong ;
Chen, Qingyan ;
Jiang, Yi .
ENERGY AND BUILDINGS, 2014, 73 :184-191