Proximal Interphalangeal Joint Silicone Arthroplasty - Comparison of Swanson and NeuFlex® Implants using a New Evaluation Score

被引:17
|
作者
Stahlenbrecher, A. [1 ]
Hoch, J. [1 ]
机构
[1] Klinikum Neustadt, Klin Hand Brust & Plast Chirurg, D-23730 Neustadt, Germany
关键词
proximal interphalangeal joint; PIPJ endoprosthesis; Swanson implant; NeuFlex (R) implant; score; HAND;
D O I
10.1055/s-0029-1220921
中图分类号
R61 [外科手术学];
学科分类号
摘要
Proximal interphalangeal joint arthroplasty with a silicone implant has proven to be successful in cases of degenerative, post-traumatic or rheumatic arthritis. The recent changing of the implant's design by introducing a 30-degree preflexion has replaced the common Swanson implant in some centres. Nevertheless, directly comparing follow-up studies between the two implant forms are still lacking as well as the use of a standard evaluation score for proximal interphalangeal joint arthroplasties. Between 1990 and 2007 a series of 67 proximal interphalangeal joint arthroplasties with a silicone device has been carried out in 54 patients. Among these a retrospective clinical and radiological investigation could be performed on 43 patients with 53 joints at 6-144, in the mean 34 months, after operation. 39 cases of degenerative, 12 cases of post-traumatic, I case of rheumatic arthritis and 1 post-traumatic arthrodesis were treated with 20 Swanson implants and 33 NeuFlex (R) implants. In 41 joints a mediolateral approach taking care of the extensor tendon's integrity was used, in 12 joints the extensor tendon was dissected longitudinally using a dorsal approach. At the time of investigation 5 implants had already been removed due to infection, implant fracture and painful extensive osteophytes. Comparing the remaining prostheses, 18 Swanson implants and 30 NeuFlex (R) implants, the latter showed a better average total range of motion, improving from 42.5 degrees preoperatively to 56 degrees postoperatively, in contrast to the Swanson implants with a deterioration from 50.8 degrees preoperatively to 47.2 degrees postoperatively. However, they were inferior to the classic Swanson implant as the joint's circumference was more enlarged by 1.8 mm in the mean and a geater finger length shortning of average 2.5 mm as well as a higher rate of stress pain and instability (15%) were evident. While the NeuFlex (R) implants led to a better subjective satisfaction, the Swanson implants gained better objective results using a new evaluation score (11% very good, 50% good, 28% satisfactory, 11% bad) than the NeuFlex (R) implants (50% good, 40% satisfactory, 10% bad). Remarkably the NeuFlex (R) devices showed an extremely high rate of early implant fractures after 8-31 months, in the mean 18 months, postoperatively, which was not seen with any of the Swanson implants - in spite of an average duration of 59.4 months.
引用
收藏
页码:156 / 165
页数:10
相关论文
共 30 条
  • [21] Surgical outcome of volar plate arthroplasty of the proximal interphalangeal joint using the Mitek Micro GII suture anchor
    Lee, Lueng-Shing
    Lee, Hung-Maan
    Hou, Yao-Tung
    Hung, Sheng-Tsai
    Chen, Jung-Kuei
    Shih, Jui-Tien
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 65 (01): : 116 - 122
  • [22] Pyrolytic carbon proximal interphalangeal joint arthroplasty: Results with minimum two-year follow-up evaluation
    Bravo, Cesar J.
    Rizzo, Marco
    Hormel, Kirsten B.
    Beckenbaugh, Robert D.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (01): : 1 - 11
  • [23] Post-Operative Contracture of the Proximal Interphalangeal Joint after Surface Replacement Arthroplasty Using a Volar Approach
    Shirakawa, Ken
    Shirota, Masahiko
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (03) : 345 - 351
  • [24] Surface Replacement Arthroplasty of the Proximal Interphalangeal Joint Using the SR PIP Implant: Long-Term Results
    Jennings, Charles D.
    Livingstone, Douglas P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (03): : 469 - 473
  • [25] Reconstruction of Delayed Proximal Interphalangeal Joint Fracture-Dislocation Using Hemi-Hamate Arthroplasty: A Case Report
    Sawant, Rishikesh, V
    Darawade, Nilesh
    Sonawane, Darshankumar
    Tawde, Anish
    Bhandari, Nikhil
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [26] Treatment of complex proximal interphalangeal joint fractures using a new dynamic external fixator: 15 cases
    Koerting, O.
    Facca, S.
    Diaconu, M.
    Liverneaux, P.
    CHIRURGIE DE LA MAIN, 2009, 28 (03) : 153 - 157
  • [27] Prosthetic arthroplasty of the proximal interphalangeal joint using a surface replacing implant (CapFlex-PIP): 3-year outcomes
    Meuser, Stefan
    Richter, Martin
    Kernich, Nikolaus
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2024, 49 (04) : 477 - 482
  • [28] Joint distraction and early mobilization using a new dynamic external finger fixator for the treatment of fracture-dislocations of the proximal interphalangeal joint
    Kodama, Akira
    Sunagawa, Toru
    Nakashima, Yuko
    Shinomiya, Rikuo
    Hayashi, Yuta
    Ochi, Mitsuo
    Adachi, Nobuo
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (06) : 959 - 966
  • [29] Proximal interphalangeal joint arthroplasty using self-locking type surface replacement implant for symptomatic osteoarthritis: Extended dorsal central splitting approach and intermediate-term outcome
    Hamada, Yoshitaka
    Minamikawa, Yoshitaka
    Usami, Satoshi
    Toyama, Takeyasu
    Sawada, Masahiro
    Saito, Takanori
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2025, 102 : 287 - 292
  • [30] A Comparison between Two Intervals of Daily Total End Range Time for Treatment of Proximal Interphalangeal Joint Flexion Contracture Using an Elastic Tension Digital Neoprene Orthosis
    Punsola-Izard, Vicenc
    Casado, Aroa
    Carnicero, Nuria
    Ozaes-Lara, Elena
    Mendieta-Zamora, Judit
    Romera-Orfila, Gemma
    Schultz, Karen S.
    Llusa, Manuel
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (05)