In vivo osteocompatibility of lotus-type porous nickel-free stainless steel in rats

被引:31
作者
Alvarez, Kelly [1 ]
Hyun, Soong-Keun [1 ]
Nakano, Takayoshi [2 ,3 ]
Umakoshi, Yukichi [2 ]
Nakajima, Hideo [1 ]
机构
[1] Osaka Univ, Inst Sci & Ind Res, Osaka 5670047, Japan
[2] Osaka Univ, Grad Sch Engn, Div Mat & Mfg Sci, Suita, Osaka 5650871, Japan
[3] Osaka Univ, Grad Sch Engn, Handai Frontier Res Ctr, Suita, Osaka 5650871, Japan
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2009年 / 29卷 / 04期
关键词
Nickel-free stainless steels; Lotus-type porous alloys; Bone ingrowth; Bone regeneration; Histomorphometry; HIGH-NITROGEN; TITANIUM MESH; BONE; HYDROXYAPATITE; FABRICATION; IMPLANTS; METALS; ARTHROPLASTY; PHOSPHATE; CORROSION;
D O I
10.1016/j.msec.2008.09.037
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The bone response to lotus-type porous nickel-free stainless steels implants was investigated using Sprague-Dawley rats. The implants were inserted in the femora and tibiae of rats (n = 60) and bone formation inside the pores of the implants was followed up to 12 weeks. Bone ingrowth in transverse histological sections was calculated using an image analysis program. Shear strength of the bone-implant interface was evaluated by the push-out test. Histological examination showed that bone grew into apparent direct contact with the implant surface and into the pores, which sizes were between 70-650 mu m. At 12 weeks, maximum compressive shear strengths of 24 +/- 1 MPa were obtained; these values are substantially higher than the typical shear strength achieved by porous-coated materials. These results clearly indicate that lotus-type porous structure allowed bone cells and tissue to invade the implant throughout superficial porous spaces, which resulted in an efficient biological fixation responsible for the mechanical stability at the implantation site. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1182 / 1190
页数:9
相关论文
共 51 条
[1]   Fabrication and properties of Lotus-type porous nickel-free stainless steel for biomedical applications [J].
Alvarez, K. ;
Sato, K. ;
Hyun, S. K. ;
Nakajima, H. .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (01) :44-50
[2]  
ALVAREZ K, J MAT SCI M IN PRESS
[3]  
Alvarez K, 2008, CORROS SCI, V50, P183, DOI 10.1016/j.corsci.2007.06.004
[4]  
[Anonymous], 1992, ANN BOOK ASTM STAND
[5]  
Ashby M., 1997, CELLULAR SOLIDS STRU
[6]  
Ayers RA, 1999, J BIOMED MATER RES, V47, P54, DOI 10.1002/(SICI)1097-4636(199910)47:1<54::AID-JBM7>3.0.CO
[7]  
2-P
[8]  
BARON R, 1990, BONE HISTOMORPHOMETR, P13
[9]   NICKEL, COBALT AND CHROMIUM IN CONSUMER PRODUCTS - A ROLE IN ALLERGIC CONTACT-DERMATITIS [J].
BASKETTER, DA ;
BRIATICOVANGOSA, G ;
KAESTNER, W ;
LALLY, C ;
BONTINCK, WJ .
CONTACT DERMATITIS, 1993, 28 (01) :15-25
[10]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1