Single frequency versus bioimpedance spectroscopy for the assessment of lymphedema

被引:62
作者
York, S. L. [1 ]
Ward, L. C. [2 ]
Czerniec, S. [1 ]
Lee, M. J. [1 ]
Refshauge, K. M. [1 ]
Kilbreath, S. L. [1 ]
机构
[1] Univ Sydney, Fac Hlth Sci, Lidcombe, NSW 2141, Australia
[2] Univ Queensland, Sch Mol & Microbial Sci, Brisbane, Qld, Australia
关键词
Lymphedema; Breast cancer; Bioimpedance spectroscopy; Single frequency bioimpedance; Multiple frequency bioimpedance;
D O I
10.1007/s10549-008-0090-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background The aims were to determine (i) whether single frequency bioimpedance analysis (SFBIA) is as accurate as bioimpedance spectroscopy (BIS) in measurement of extracellular fluid and (ii) whether change in extracellular fluid was specific to only the limb directly affected by surgery. Methods Arms of the control (n = 28) and arm lymphedema group (n = 28) and legs of the leg lymphedema group (n = 16) were assessed with SFBIA. All four limbs in all participants were assessed with BIS. All measurements occurred in a single session. Results BIS-measured ratios were highly concordant with those obtained with SFBIA (r (c) = 0.99, P < 0.001). Repeated measures ANOVA revealed that the ratio involving the lymphedema limb was different to the ratio of the non-oedematous limbs which was not significantly different to the arm or leg ratios of the control group. Conclusions SFBIA is a simple accurate alternative to BIS for the clinical assessment of unilateral lymphedema. BIS discriminates those with clinical diagnosis of unilateral lymhoedema from those without the diagnosis.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 18 条
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
CASLEYSMITH JR, 1994, LYMPHOLOGY, V27, P56
[4]   IMPROVED PREDICTION OF EXTRACELLULAR AND TOTAL-BODY WATER USING IMPEDANCE LOCI GENERATED BY MULTIPLE FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
CORNISH, BH ;
THOMAS, BJ ;
WARD, LC .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03) :337-346
[5]  
Cornish BH, 2001, LYMPHOLOGY, V34, P2
[6]   Optimizing electrode sites for segmental bioimpedance measurements [J].
Cornish, BH ;
Jacobs, A ;
Thomas, BJ ;
Ward, LC .
PHYSIOLOGICAL MEASUREMENT, 1999, 20 (03) :241-250
[7]   Comparison of methods to diagnose lymphoedema among breast cancer survivors: 6-month follow-up [J].
Hayes, S ;
Cornish, B ;
Newman, B .
BREAST CANCER RESEARCH AND TREATMENT, 2005, 89 (03) :221-226
[8]   A CONCORDANCE CORRELATION-COEFFICIENT TO EVALUATE REPRODUCIBILITY [J].
LIN, LI .
BIOMETRICS, 1989, 45 (01) :255-268
[9]  
McBride GB., 2005, PROPOSAL STRENGTH OF
[10]  
SENER SF, 2001, CANCER, V924, P748