Effect of Entry Temperature on Forced Convection Heat Transfer With Viscous Dissipation in Thermally Developing Region of Concentric Annuli

被引:5
|
作者
Kumar, M. M. J. [1 ]
Satyamurty, V. V. [2 ]
机构
[1] Vellore Inst Technol Univ, Sch Mech & Bldg Sci, Vellore 632014, Tamil Nadu, India
[2] Indian Inst Technol, Dept Mech Engn, Kharagpur 721302, W Bengal, India
来源
关键词
heat transfer; forced convection; concentric annuli; viscous dissipation; thermally developing region; FLUID;
D O I
10.1115/1.4030908
中图分类号
O414.1 [热力学];
学科分类号
摘要
Steady laminar forced convection heat transfer in the thermal entrance region of concentric annuli has been studied considering viscous dissipation characterized by the Brinkman number. The inner and outer pipes have been kept at constant and equal temperature. Two cases of entry temperatures have been considered, case 1: an entry temperature that varies with the radial coordinate, obtained by an adiabatically prepared fluid, i.e., attained by the fluid due to viscous dissipation in an adiabatic concentric annular duct and case 2: the conventional uniform entry temperature. The numerical results presented include the nondimensional temperature profiles, Nusselt numbers, and heat transferred from (or to) the inner and outer pipes. It has been shown from the numerical solutions that it is necessary to employ the dissipative entry temperature in place of conventional uniform entry temperature for higher Brinkman numbers. The results for circular pipes follow when the radius ratio takes the limiting value of zero.
引用
收藏
页数:8
相关论文
共 50 条