Design of the pole placement controller for D-STATCOM in mitigating three phase fault

被引:0
|
作者
Mariun, Norman [1 ]
Hizam, Hashim [1 ]
Izzri, A. W. Noor [1 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Dept Elect & Elect Engn, Serdang 43300, Selangor, Malaysia
来源
IEEE POWER ENGINEERING SOCIETY INAUGURAL 2005 CONFERENCE AND EXPOSITION IN AFRICA | 2005年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a design of pole placement controller for D-STATCOM in mitigation of three phase fault. In the pole placement method the existing poles are shifted to lite new locations of poles at the real-imaginary axes for better response. This type of controller is able to control the amount of injected current or voltage or both from the D-STATCOM inverters to mitigate the three phase fault by referring to the currents that are the input to the pole placement controller. The controller efficiency was tested in the different percentage of voltage sag that occurs during the three phase fault. The controller and the D-STATCOM were designed using SIMULINK and Power System Blockset toolbox available in MATLAB program.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
  • [41] A novel model predictive-fuzzy logic hybrid controller design for D-STATCOM in wind energy distribution systems
    Yanmaz, K.
    Altas, I. H.
    Mengi, O. O.
    GLOBAL NEST JOURNAL, 2018, 20 (01): : 177 - 182
  • [42] DSA/WDO Based PI Controller tuning for D-STATCOM for Reactive power Compensation
    Patel, Pritam
    Rout, Srikant
    Swain, Milan
    Patel, Punyaban
    2015 IEEE UP SECTION CONFERENCE ON ELECTRICAL COMPUTER AND ELECTRONICS (UPCON), 2015,
  • [43] Design of Decoupling Current Control with Symmetrical Optimum Method for D-STATCOM
    Somsai, Kittaya
    Kulworawanichpong, Thanatchai
    Voraphonpiput, Nitus
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [44] Design Tradeoffs in Selection of the DC-Side Voltage for a D-STATCOM
    Ziaeinejad, Saleh
    Mehrizi-Sani, Ali
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (06) : 3230 - 3232
  • [45] A repetitive-based controller in stationary reference frame for D-Statcom in unbalanced operation
    Escobar, G.
    Valdez, A. A.
    Torres-Olguin, R. E.
    Martinez-Montejano, M. F.
    2006 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-7, 2006, : 1388 - 1393
  • [46] Phase-Locked Loop (PLL) Controller for Distribution Synchronous Static Compensator (D-STATCOM) to Mitigate Voltage Flicker
    Jamaludin, N. F.
    Abidin, A. F.
    PROCEEDINGS OF THE 2013 IEEE 7TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO2013), 2013, : 334 - 339
  • [47] A D-STATCOM Based On Goertzel Algorithm for Sag Detection and a Novel Current Mode Controller
    Najafi, E.
    Yatim, A. H. M.
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 2, 2010, : 441 - 446
  • [48] Design of Digital Controller using Pole Placement Method
    Raut, Hema D.
    Singh, Anupama
    Patil, M. D.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON CONTROL AUTOMATION, COMMUNICATION AND ENERGY CONSERVATION INCACEC 2009 VOLUME II, 2009, : 987 - +
  • [49] LCL output filter design and the influence to the D-STATCOM compensation characteristic
    Yao Xin-li
    Luo Long-fu
    Xu Jia-zhu
    Liao Wen-di
    2011 INTERNATIONAL CONFERENCE ON ELECTRONICS, COMMUNICATIONS AND CONTROL (ICECC), 2011, : 313 - 316
  • [50] Design of High efficiency and Compact Filter Inductor for D-StatCom Inverter
    Panchal, Chirag
    Stegen, Sascha
    Lu, Junwei
    Butler, Dale
    PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 1127 - 1132