Numerical investigations of Re-independence and influence of wall heating on flow characteristics and ventilation in full-scale 2D street canyons

被引:53
作者
Yang, Hongyu [1 ]
Lam, Cho Kwong Charlie [1 ,2 ]
Lin, Yuanyuan [1 ,3 ]
Chen, Lan [1 ,4 ]
Mattsson, Magnus [3 ]
Sandberg, Mats [3 ]
Hayati, Abolfazl [3 ]
Claesson, Leif [3 ]
Hang, Jian [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Sch Atmospher Sci, Guangdong Prov Key Lab Climate Change & Nat Disas, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Key Lab Trop Atmosphere Ocean Syst, Minist Educ, Zhuhai 519000, Peoples R China
[3] Univ Gavle, Dept Bldg Engn Energy Syst & Sustainabil Sci, S-80176 Gavle, Sweden
[4] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
2D deep street canyon; Reynolds number-independence; Buoyancy effect; Street ventilation; Computational fluid dynamics (CFD); Net escape velocity;
D O I
10.1016/j.buildenv.2020.107510
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Validated by wind tunnel data, this study numerically investigates the integrated impacts of wind and thermal buoyancy on urban turbulence, ventilation and pollutant dispersion in full-scale 2D deep street canyons (aspect ratio AR = H/W = 3 and 5, W = 24 m). Isothermal urban airflows for such deep street canyons can be Reynoldsnumber-independent when reference Reynolds number (Re) exceeds the critical Re (Re-c similar to 10(6),10(7) when AR = 3, 5), i.e. AR = 5 experiences two main vortices and one-order smaller NEV* (similar to 10(-3), the normalized net escape velocity) than AR = 3 with a single main vortex (NEV*similar to 10(-2)). With sufficiently large Re (Re > Re-c) and the same air-wall temperature difference (Ri = 2.62, 4.36 when AR = 3, 5), four uniform wall heating patterns were considered, including leeward-wall heating (L-H), windward-wall heating (W-H), ground heating (G-H), and all-wall heating (A-H). Various indicators were adopted to evaluate street ventilation and pollutant dilution capacity (e.g. age of air (tau,s), NEV*, pollutant transport rates (PTR)). Full-scale wall heating produces a strong upward near-wall buoyancy force, which significantly influences flow patterns and improves street ventilation for most cases. When AR = 3, L-H strengthens the single-vortex airflow. When AR = 5, L-H converts the isothermal double vortices into a single-clockwise vortex. For both ARs, W-H reverses the main clockwise vortex to an enhanced counterclockwise one, moreover G-H and A-H cause a more complicated multi-vortex pattern than isothermal cases. Overall, when AR = 3, L-H and W-H increase NEV* by 68% and 40% than the isothermal case. When AR = 5, four wall heating patterns all raise NEV* considerably (by 150%-556%). For both ARs, the L-H, W-H and A-H amplify the contribution of mean flows on removing pollutants but reduce that by turbulent diffusion compared with isothermal cases.
引用
收藏
页数:20
相关论文
共 91 条
  • [81] City ventilation of Hong Kong at no-wind conditions
    Yang, Lina
    Li, Yuguo
    [J]. ATMOSPHERIC ENVIRONMENT, 2009, 43 (19) : 3111 - 3121
  • [82] Integrated assessment of indoor and outdoor ventilation in street canyons with naturally -ventilated buildings by various ventilation indexes
    Yang, Xia
    Zhang, Yong
    Hang, Jian
    Lin, Yuanyuan
    Mattsson, Magnus
    Sandberg, Mats
    Zhang, Ming
    Wang, Kai
    [J]. BUILDING AND ENVIRONMENT, 2020, 169
  • [83] The "plant evaluation model" for the assessment of the impact of vegetation on outdoor microclimate in the urban environment
    Yang, Yujin
    Gatto, Elisa
    Gao, Zhi
    Buccolieri, Riccardo
    Morakinyo, Tobi Eniolu
    Lan, Hongning
    [J]. BUILDING AND ENVIRONMENT, 2019, 159
  • [84] Air ventilation impacts of the "wall effect" resulting from the alignment of high-rise buildings
    Yim, S. H. L.
    Fung, J. C. H.
    Lau, A. K. H.
    Kot, S. C.
    [J]. ATMOSPHERIC ENVIRONMENT, 2009, 43 (32) : 4982 - 4994
  • [85] Cooperative project for CFD prediction of pedestrian wind environment in the Architectural Institute of Japan
    Yoshie, R.
    Mochida, A.
    Tominaga, Y.
    Kataoka, H.
    Harimoto, K.
    Nozu, T.
    Shirasawa, T.
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2007, 95 (9-11) : 1551 - 1578
  • [86] Impacts of urban configuration on urban heat island: An empirical study in China mega-cities
    Yue, Wenze
    Liu, Xue
    Zhou, Yuyu
    Liu, Yong
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 671 : 1036 - 1046
  • [87] Integrated impacts of turbulent mixing and NOX-O3 photochemistry on reactive pollutant dispersion and intake fraction in shallow and deep street canyons
    Zhang, Keer
    Chen, Guanwen
    Zhang, Yong
    Liu, Shanhe
    Wang, Xuemei
    Wang, Baoming
    Hang, Jian
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 712
  • [88] Numerical evaluations of urban design technique to reduce vehicular personal intake fraction in deep street canyons
    Zhang, Keer
    Chen, Guanwen
    Wang, Xuemei
    Liu, Shanhe
    Mak, Cheuk Ming
    Fan, Yifan
    Hang, Jian
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 653 : 968 - 994
  • [89] Effect of real-time boundary wind conditions on the air flow and pollutant dispersion in an urban street canyon-Large eddy simulations
    Zhang, Yun-Wei
    Gu, Zhao-Lin
    Cheng, Yan
    Lee, Shun-Cheng
    [J]. ATMOSPHERIC ENVIRONMENT, 2011, 45 (20) : 3352 - 3359
  • [90] Numerical Simulation and In Situ Investigation of Fine Particle Dispersion in an Actual Deep Street Canyon in Hong Kong
    Zhang, Yun-Wei
    Gu, Zhao-Lin
    Lee, Shun-Cheng
    Fu, Tzung-May
    Ho, Kin-Fai
    [J]. INDOOR AND BUILT ENVIRONMENT, 2011, 20 (02) : 206 - 216