Numerical investigations of Re-independence and influence of wall heating on flow characteristics and ventilation in full-scale 2D street canyons

被引:53
作者
Yang, Hongyu [1 ]
Lam, Cho Kwong Charlie [1 ,2 ]
Lin, Yuanyuan [1 ,3 ]
Chen, Lan [1 ,4 ]
Mattsson, Magnus [3 ]
Sandberg, Mats [3 ]
Hayati, Abolfazl [3 ]
Claesson, Leif [3 ]
Hang, Jian [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Sch Atmospher Sci, Guangdong Prov Key Lab Climate Change & Nat Disas, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Key Lab Trop Atmosphere Ocean Syst, Minist Educ, Zhuhai 519000, Peoples R China
[3] Univ Gavle, Dept Bldg Engn Energy Syst & Sustainabil Sci, S-80176 Gavle, Sweden
[4] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
2D deep street canyon; Reynolds number-independence; Buoyancy effect; Street ventilation; Computational fluid dynamics (CFD); Net escape velocity;
D O I
10.1016/j.buildenv.2020.107510
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Validated by wind tunnel data, this study numerically investigates the integrated impacts of wind and thermal buoyancy on urban turbulence, ventilation and pollutant dispersion in full-scale 2D deep street canyons (aspect ratio AR = H/W = 3 and 5, W = 24 m). Isothermal urban airflows for such deep street canyons can be Reynoldsnumber-independent when reference Reynolds number (Re) exceeds the critical Re (Re-c similar to 10(6),10(7) when AR = 3, 5), i.e. AR = 5 experiences two main vortices and one-order smaller NEV* (similar to 10(-3), the normalized net escape velocity) than AR = 3 with a single main vortex (NEV*similar to 10(-2)). With sufficiently large Re (Re > Re-c) and the same air-wall temperature difference (Ri = 2.62, 4.36 when AR = 3, 5), four uniform wall heating patterns were considered, including leeward-wall heating (L-H), windward-wall heating (W-H), ground heating (G-H), and all-wall heating (A-H). Various indicators were adopted to evaluate street ventilation and pollutant dilution capacity (e.g. age of air (tau,s), NEV*, pollutant transport rates (PTR)). Full-scale wall heating produces a strong upward near-wall buoyancy force, which significantly influences flow patterns and improves street ventilation for most cases. When AR = 3, L-H strengthens the single-vortex airflow. When AR = 5, L-H converts the isothermal double vortices into a single-clockwise vortex. For both ARs, W-H reverses the main clockwise vortex to an enhanced counterclockwise one, moreover G-H and A-H cause a more complicated multi-vortex pattern than isothermal cases. Overall, when AR = 3, L-H and W-H increase NEV* by 68% and 40% than the isothermal case. When AR = 5, four wall heating patterns all raise NEV* considerably (by 150%-556%). For both ARs, the L-H, W-H and A-H amplify the contribution of mean flows on removing pollutants but reduce that by turbulent diffusion compared with isothermal cases.
引用
收藏
页数:20
相关论文
共 91 条
  • [41] Large-eddy simulations on the effects of surface geometry of building arrays on turbulent organized structures
    Kanda, M
    [J]. BOUNDARY-LAYER METEOROLOGY, 2006, 118 (01) : 151 - 168
  • [42] Quality and reliability of LES of convective scalar transfer at high Reynolds numbers
    Li, Qi
    Bou-Zeid, Elie
    Anderson, William
    Grimmond, Sue
    Hultmark, Marcus
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 102 : 959 - 970
  • [43] Recent progress in CFD modelling of wind field and pollutant transport in street canyons
    Li, Xian-Xiang
    Liu, Chun-Ho
    Leung, Dennis Y. C.
    Lam, K. M.
    [J]. ATMOSPHERIC ENVIRONMENT, 2006, 40 (29) : 5640 - 5658
  • [44] Flow and Pollutant Transport in Urban Street Canyons of Different Aspect Ratios with Ground Heating: Large-Eddy Simulation
    Li, Xian-Xiang
    Britter, Rex E.
    Norford, Leslie K.
    Koh, Tieh-Yong
    Entekhabi, Dara
    [J]. BOUNDARY-LAYER METEOROLOGY, 2012, 142 (02) : 289 - 304
  • [45] Numerical investigation of pollutant transport characteristics inside deep urban street canyons
    Li, Xian-Xiang
    Liu, Chun-Ho
    Leung, Dennis Y. C.
    [J]. ATMOSPHERIC ENVIRONMENT, 2009, 43 (15) : 2410 - 2418
  • [46] New ventilation index for evaluating imperfect mixing conditions - Analysis of Net Escape Velocity based on RANS approach
    Lim, Eunsu
    Ito, Kazuhide
    Sandberg, Mats
    [J]. BUILDING AND ENVIRONMENT, 2013, 61 : 45 - 56
  • [47] Integrated Effects of Street Layouts and Wall Heating on Vehicular Pollutant Dispersion and their Reentry Toward Downstream Canyons
    Lin, Lin
    Hang, Jian
    Wang, Xiaoxue
    Wang, Xuemei
    Fan, Shaojia
    Fan, Qi
    Liu, Yonghong
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2016, 16 (12) : 3142 - 3163
  • [48] Quantitative ventilation assessments of idealized urban canopy layers with various urban layouts and the same building packing density
    Lin, Man
    Hang, Jian
    Li, Yuguo
    Luo, Zhiwen
    Sandberg, Mats
    [J]. BUILDING AND ENVIRONMENT, 2014, 79 : 152 - 167
  • [49] Lin Y.Y., 2019, THESIS SUN YAT SEN U
  • [50] On the prediction of air and pollutant exchange rates in street canyons of different aspect ratios using large-eddy simulation
    Liu, CH
    Leung, DYC
    Barth, MC
    [J]. ATMOSPHERIC ENVIRONMENT, 2005, 39 (09) : 1567 - 1574