Numerical investigations of Re-independence and influence of wall heating on flow characteristics and ventilation in full-scale 2D street canyons

被引:53
作者
Yang, Hongyu [1 ]
Lam, Cho Kwong Charlie [1 ,2 ]
Lin, Yuanyuan [1 ,3 ]
Chen, Lan [1 ,4 ]
Mattsson, Magnus [3 ]
Sandberg, Mats [3 ]
Hayati, Abolfazl [3 ]
Claesson, Leif [3 ]
Hang, Jian [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Sch Atmospher Sci, Guangdong Prov Key Lab Climate Change & Nat Disas, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Key Lab Trop Atmosphere Ocean Syst, Minist Educ, Zhuhai 519000, Peoples R China
[3] Univ Gavle, Dept Bldg Engn Energy Syst & Sustainabil Sci, S-80176 Gavle, Sweden
[4] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
2D deep street canyon; Reynolds number-independence; Buoyancy effect; Street ventilation; Computational fluid dynamics (CFD); Net escape velocity;
D O I
10.1016/j.buildenv.2020.107510
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Validated by wind tunnel data, this study numerically investigates the integrated impacts of wind and thermal buoyancy on urban turbulence, ventilation and pollutant dispersion in full-scale 2D deep street canyons (aspect ratio AR = H/W = 3 and 5, W = 24 m). Isothermal urban airflows for such deep street canyons can be Reynoldsnumber-independent when reference Reynolds number (Re) exceeds the critical Re (Re-c similar to 10(6),10(7) when AR = 3, 5), i.e. AR = 5 experiences two main vortices and one-order smaller NEV* (similar to 10(-3), the normalized net escape velocity) than AR = 3 with a single main vortex (NEV*similar to 10(-2)). With sufficiently large Re (Re > Re-c) and the same air-wall temperature difference (Ri = 2.62, 4.36 when AR = 3, 5), four uniform wall heating patterns were considered, including leeward-wall heating (L-H), windward-wall heating (W-H), ground heating (G-H), and all-wall heating (A-H). Various indicators were adopted to evaluate street ventilation and pollutant dilution capacity (e.g. age of air (tau,s), NEV*, pollutant transport rates (PTR)). Full-scale wall heating produces a strong upward near-wall buoyancy force, which significantly influences flow patterns and improves street ventilation for most cases. When AR = 3, L-H strengthens the single-vortex airflow. When AR = 5, L-H converts the isothermal double vortices into a single-clockwise vortex. For both ARs, W-H reverses the main clockwise vortex to an enhanced counterclockwise one, moreover G-H and A-H cause a more complicated multi-vortex pattern than isothermal cases. Overall, when AR = 3, L-H and W-H increase NEV* by 68% and 40% than the isothermal case. When AR = 5, four wall heating patterns all raise NEV* considerably (by 150%-556%). For both ARs, the L-H, W-H and A-H amplify the contribution of mean flows on removing pollutants but reduce that by turbulent diffusion compared with isothermal cases.
引用
收藏
页数:20
相关论文
共 91 条
  • [1] Wind-induced single-sided natural ventilation in buildings near a long street canyon: CFD evaluation of street configuration and envelope design
    Ai, Z. T.
    Mak, C. M.
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2018, 172 : 96 - 106
  • [2] Buoyant flows in street canyons: Validation of CFD simulations with wind tunnel measurements
    Allegrini, Jonas
    Dorer, Viktor
    Carmeliet, Jan
    [J]. BUILDING AND ENVIRONMENT, 2014, 72 : 63 - 74
  • [3] Wind tunnel measurements of buoyant flows in street canyons
    Allegrini, Jonas
    Dorer, Viktor
    Carmeliet, Jan
    [J]. BUILDING AND ENVIRONMENT, 2013, 59 : 315 - 326
  • [4] ANSYS Inc, 2013, ANSYS FLUENT USERSGU
  • [5] CFD simulation of urban microclimate: Validation using high-resolution field measurements
    Antoniou, Nestoras
    Montazeri, Hamid
    Neophytou, Marina
    Blocken, Bert
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 695
  • [6] Towards the application of indoor ventilation efficiency indices to evaluate the air quality of urban areas
    Bady, Mahmoud
    Kato, Shinsuke
    Huang, Hong
    [J]. BUILDING AND ENVIRONMENT, 2008, 43 (12) : 1991 - 2004
  • [7] CFD simulation of the atmospheric boundary layer: wall function problems
    Blocken, Bert
    Stathopoulos, Ted
    Carmeliet, Jan
    [J]. ATMOSPHERIC ENVIRONMENT, 2007, 41 (02) : 238 - 252
  • [8] Reduction of outdoor particulate matter concentrations by local removal in semi-enclosed parking garages: A preliminary case study for Eindhoven city center
    Blocken, Bert
    Vervoort, Rob
    van Hooff, Twan
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2016, 159 : 80 - 98
  • [9] CFD modeling of the impact of solar radiation in a tridimensional urban canyon at different wind conditions
    Bottillo, S.
    Vollaro, A. De Lieto
    Galli, G.
    Vallati, A.
    [J]. SOLAR ENERGY, 2014, 102 : 212 - 222
  • [10] City breathability and its link to pollutant concentration distribution within urban-like geometries
    Buccolieri, Riccardo
    Sandberg, Mats
    Di Sabatino, Silvana
    [J]. ATMOSPHERIC ENVIRONMENT, 2010, 44 (15) : 1894 - 1903