A convolutional neural network for ultra-low-dose CT denoising and emphysema screening

被引:42
作者
Zhao, Tingting [1 ]
McNitt-Gray, Michael [2 ,3 ]
Ruan, Dan [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Biomed Phys, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Dept Radiol, Los Angeles, CA 90095 USA
关键词
deep network; emphasema screening; low-dose CT; quantitative imaging; ITERATIVE RECONSTRUCTION; LUNG; IMPLEMENTATION; SMOKERS; SPARSE;
D O I
10.1002/mp.13666
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Reducing dose level to achieve ALARA is an important task in diagnostic and therapeutic applications of computed tomography (CT) imaging. Effective image quality enhancement strategies are crucial to compensate for the degradation caused by dose reduction. In the past few years, deep learning approaches have demonstrated promising denoising performance on natural/synthetic images. This study tailors a neural network model for (ultra-)low-dose CT denoising, and assesses its performance in enhancing CT image quality and emphysema quantification. Methods The noise statistics in low-dose CT images has its unique characteristics and differs from that used in general denoising models. In this study, we first simulate the paired ultra-low-dose and targeted high-quality image of reference, with a well-validated pipeline. These paired images are used to train a denoising convolutional neural network (DnCNN) with residual mapping. The performance of the DnCNN tailored to CT denoising (DnCNN-CT) is assessed over various dose reduction levels, with respect to both image quality and emphysema scoring quantification. The possible over-smoothing behavior of DnCNN and its impact on different subcohort of patients are also investigated. Results Performance evaluation results showed that DnCNN-CT provided significant image quality enhancement, especially for very-low-dose level. With DnCNN-CT denoising on 3%-dose cases, the peak signal-to-noise ratio improved by 8 dB and the structure similarity index increased by 0.15. This outperformed the original DnCNN and the state-of-the-art nonlocal-mean-type denoising scheme. Emphysema mask was also investigated, where lung voxels of abnormally low attenuation coefficient were marked as potential emphysema. Emphysema mask generated after DnCNN-CT denoising on 3%-dose image was demonstrated to agree well with that from the full-dose reference. Despite over-smoothing in DnCNN denoising, which contributed to slight underestimation of emphysema score compared to the reference, such minor overcorrection did not affect clinical conclusions. The proposed method provided effective detection for cases with appreciable emphysema while serving as a reasonable correction for normal cases without emphysema. Conclusions This work provides a tailored DnCNN for (ultra-)low-dose CT denoising, and demonstrates significant improvement on both the image quality and the clinical emphysema quantification accuracy over various dose levels. The clinical conclusion of emphysema obtained from the denoised low-dose images agrees well with that from the full-dose ones.
引用
收藏
页码:3941 / 3950
页数:10
相关论文
共 23 条
  • [1] Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
    Aberle, Denise R.
    Adams, Amanda M.
    Berg, Christine D.
    Black, William C.
    Clapp, Jonathan D.
    Fagerstrom, Richard M.
    Gareen, Ilana F.
    Gatsonis, Constantine
    Marcus, Pamela M.
    Sicks, JoRean D.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) : 395 - 409
  • [2] [Anonymous], 2012, Proceedings of the IEEE Computer Society Conference on Computer Vision and Pattern Recognition
  • [3] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [4] Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer
    Brenner, DJ
    [J]. RADIOLOGY, 2004, 231 (02) : 440 - 445
  • [5] Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Choo, Ji Yung
    Goo, Jin Mo
    Lee, Chang Hyun
    Park, Chang Min
    Park, Sang Joon
    Shim, Mi-Suk
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (04) : 799 - 806
  • [6] Image denoising by sparse 3-D transform-domain collaborative filtering
    Dabov, Kostadin
    Foi, Alessandro
    Katkovnik, Vladimir
    Egiazarian, Karen
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2007, 16 (08) : 2080 - 2095
  • [7] Image denoising via sparse and redundant representations over learned dictionaries
    Elad, Michael
    Aharon, Michal
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2006, 15 (12) : 3736 - 3745
  • [8] Deep Residual Learning for Image Recognition
    He, Kaiming
    Zhang, Xiangyu
    Ren, Shaoqing
    Sun, Jian
    [J]. 2016 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2016, : 770 - 778
  • [9] He Kaiming, 2018, ABS181108883 CORR
  • [10] CT-quantified emphysema in male heavy smokers: association with lung function decline
    Hoesein, Firdaus A. A. Mohamed
    de Hoop, Bartjan
    Zanen, Pieter
    Gietema, Hester
    Kruitwagen, Cas L. J. J.
    van Ginneken, Bram
    Isgum, Ivana
    Mol, Christian
    van Klaveren, Rob J.
    Dijkstra, Akkelies E.
    Groen, Harry J. M.
    Boezen, H. Marike
    Postma, Dirkje S.
    Prokop, Mathias
    Lammers, Jan-Willem J.
    [J]. THORAX, 2011, 66 (09) : 782 - 787