Performance improvement of the vapour compression refrigeration cycle by a two-phase constant area ejector

被引:97
作者
Bilir, Nagihan [1 ]
Ersoy, H. Kursad [1 ]
机构
[1] Selcuk Univ, Dept Mech Engn, Fac Engn & Architecture, TR-42250 Konya, Turkey
关键词
ejector; COP; expansion valve; optimum performance; off-design; SYSTEM;
D O I
10.1002/er.1488
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The performance of a vapour compression system that uses an ejector as an expansion device was investigated. In the analysis, a two-phase constant area ejector flow model was used. R134a was selected as the refrigerant. According to the obtained results, for any operating temperature there are different optimum values of pressure drop in the suction chamber, ejector area ratio, ejector outlet pressure and cooling coefficient of performance (COP). As the difference between condenser and evaporator temperatures increases, the improvement ratio in COP rises whereas ejector area ratio drops. The minimum COP improvement ratio in the investigated field was 10.1%, while its maximum was 22.34%. Even in the case of an off-design operation, the performance of a system with ejector is higher than that of the basic system. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:469 / 480
页数:12
相关论文
共 17 条
  • [1] Experimental investigation of an ejector refrigerator: Effect of mixing chamber geometry on system performance
    Aphornratana, S
    Chungpaibulpatana, S
    Srikhirin, P
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (05) : 397 - 411
  • [2] Effect of throat diameters of the ejector on the performance of the refrigeration cycle using a two-phase ejector as an expansion device
    Chaiwongsa, Praitoon
    Wongwises, Somchai
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (04): : 601 - 608
  • [3] Particular characteristics of transcritical CO2 refrigeration cycle with an ejector
    Deng, Jian-qiang
    Jiang, Pei-xue
    Lu, Tao
    Lu, Wei
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) : 381 - 388
  • [4] Dincer Ibrahim., 2003, REFRIGERATION SYSTEM
  • [5] Experimental investigation on the performance of the refrigeration cycle using a two-phase ejector as an expansion device
    Disawas, S
    Wongwises, S
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (06): : 587 - 594
  • [6] Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation
    Elbel, Stefan
    Hrnjak, Pega
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (03): : 411 - 422
  • [7] Performance of a solar ejector cooling-system in the southern region of Turkey
    Ersoy, H. Kursad
    Yalcin, Sakir
    Yapici, Rafet
    Ozgoren, Muammer
    [J]. APPLIED ENERGY, 2007, 84 (09) : 971 - 983
  • [8] Li D., 2006, THESIS PURDUE U US
  • [9] Transcritical CO2 refrigeration cycle with ejector-expansion device
    Li, DQ
    Groll, EA
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (05): : 766 - 773
  • [10] Performance analysis of the vapour compression cycle using ejector as an expander
    Nehdi, E.
    Kairouani, L.
    Bouzaina, M.
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (04) : 364 - 375